c/kWh
Energy rating (cooling)
2
Heating: 2
Annual electricity use
8,273 kWh
1,235 cooling + 7,038 heating
Estimated running cost
$2,730 / year
$228 / month Β· $27,301 over 10 years
Capacity
18 kW cooling
20 kW heating

1% less electricity than the median of 50 comparable 18 kW reverse cycle ducted split system registrations (8,396 kWh a year) in the cold zone. Uses less than 52% of them.

Across all 3,566 air conditioner registrations sold in Australia, it uses less than 18% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ— 33c/kWh in NZD; change the price above to your tariff.

Panasonic U-180PZH2R8 running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 8,273$2,730$27,301
Mixed zone 4,519$1,491$14,913
Hot zone 5,939$1,960$19,599

At 33c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Heat pumps that use less electricity

Same configuration and type, cooling capacity within 12% of 18 kW, at least 3% lower annual kWh in the cold zone.

ModelStarsEst. cost / yrCompare
Carrier 38QSH170D8S / 42QSH170D8S17 kW heating17 kW cooling6,907 kWh/yr3.5$2,279
Midea DUCMI170IHB/UCMI170OB17.5 kW heating17 kW cooling7,066 kWh/yr4$2,332
Midea DUCMI170IHB/UCMI170OB17.5 kW heating17 kW cooling7,066 kWh/yr4$2,332
Actron Air LRC-170CS / LRE-170CS17.6 kW heating16.6 kW cooling7,156 kWh/yr4$2,361
Actron Air LRC-170DS / LRE-170DS18 kW heating17 kW cooling7,212 kWh/yr3.5$2,380

Heat pumps similar to the Panasonic U-180PZH2R8

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
Daikin RZAS180DV1 / FDYA180AV120 kW heating18 kW cooling7,987 kWh/yr2.5$2,636
Mitsubishi Electric PUZ-ZM180VKA-A / PEA-M180LAA20 kW heating18 kW cooling8,484 kWh/yr2.5$2,800
Daikin RZAS180DY1 / FDYA180AV120 kW heating18 kW cooling7,978 kWh/yr2.5$2,633
Gree GFH65DEXL-S6DND7D/O / GFH65DEXL-S6DND7D/I19.5 kW heating18 kW cooling8,528 kWh/yr3$2,814
Reclaim Energy CA-D180D1HWH-ODU/CA-D180D1HWH-IDU20 kW heating18 kW cooling8,488 kWh/yr3$2,801
TCL TCD180D1HWHS2-DVO/TCD180D1HWHS2-DVI20 kW heating18 kW cooling8,488 kWh/yr3$2,801
Fujitsu AOTG65LRLA/ARTG65LHTA20 kW heating18 kW cooling7,679 kWh/yr10$2,534
Mitsubishi Electric PUZ-ZM180YKA-A / PEA-M180LAA20 kW heating18 kW cooling8,483 kWh/yr2.5$2,799

Compare U-180PZH2R8/S-180PE3R5B with another model

Panasonic U-180PZH2R8 specifications

Type
Reverse cycle
Configuration
Split system
Air distribution
Ducted
Indoor unit
–
Rated cooling capacity (35 Β°C)
18.00 kW
Cooling power input
–
Rated heating capacity (7 Β°C)
20.00 kW
Heating power input
–
EER, full load (tested)
3.34
COP, full load (tested)
3.82
Rated AEER
3.15
Rated ACOP
3.69
Standby power (PIA)
25.8 W
Compressor
Variable speed, Inverter
Refrigerant
R32
Power supply
Three phase
Indoor sound power
–
Outdoor sound power
–
Demand response (AS/NZS 4755)
Yes
Country of manufacture
Malaysia

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

Panasonic U-180PZH2R8 zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––2,6242,190
Coldresidential2.02.01,2357,038
Mixedcommercial––3,2961,137
Mixedresidential2.02.51,9112,608
Hotcommercial––7,412261
Hotresidential2.53.55,539400
Part-load test points (23 values)
h__h1_min_cap_power_rated
1060 W
h__h2_ext_cap_power_rated
6210 W
c__t1_half_cap_power_rated
2200 W
c__t1_have_min_cap_results
No
h__h1_half_cap_power_rated
2000 W
h__h1_have_min_cap_results
Yes
h__h2_have_full_cap_results
No
h__h2_have_half_cap_results
No
h__h3_have_full_cap_results
No
h__h3_have_half_cap_results
No
h__h1_min_cap_heat_cap_rated
5500 W
h__h2_ext_cap_heat_cap_rated
18000 W
h__h1_half_cap_heat_cap_rated
10100 W
h__h2_is_capable_extended_load
Yes
c__low_temp_min_cap_power_rated
1260 W
c__low_temp_full_cap_power_rated
5145.82 W
c__low_temp_half_cap_power_rated
2010.8 W
c__low_temp_have_min_cap_results
Yes
c__t1_half_cap_cooling_cap_rated
9100 W
c__low_temp_have_half_cap_results
No
c__low_temp_min_cap_cooling_cap_rated
6300 W
c__low_temp_full_cap_cooling_cap_rated
19386 W
c__low_temp_half_cap_cooling_cap_rated
9800.7 W

New Zealand E3 registration details

Registration number
AAC8062
GEMS registration id
–
Status
approved
Registration expires
19 February 2029
Registered for sale in
Australia, New Zealand
Family
–
Regulatory standard
Greenhouse and Energy Minimum Standards (Air Conditioners up to 65kW) Determination 2019
Test standard
AS/NZS 3823.1.2:2012
MEPS
2019
Product class
11

Source: E3 programme registration data (EECA, New Zealand) (trans-Tasman E3 registration data published by DCCEEW on data.gov.au, CC BY 3.0 AU). Dataset published 28 October 2026; last checked 29 October 2026. How the derived figures are calculated.