c/kWh
Energy rating (cooling)
2
Heating: 2
Annual electricity use
2,651 kWh
446 cooling + 2,205 heating
Estimated running cost
$875 / year
$73 / month Β· $8,748 over 10 years
Capacity
6 kW cooling
6 kW heating

4% less electricity than the median of 25 comparable 6 kW reverse cycle ducted split system registrations (2,771 kWh a year) in the cold zone. Uses less than 80% of them.

Across all 3,611 air conditioner registrations sold in Australia, it uses less than 67% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ— 33c/kWh in NZD; change the price above to your tariff.

Panasonic U-60PZ3R5 running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 2,651$875$8,748
Mixed zone 1,551$512$5,118
Hot zone 2,103$694$6,940

At 33c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Heat pumps that use less electricity

Same configuration and type, cooling capacity within 12% of 6 kW, at least 3% lower annual kWh in the cold zone.

ModelStarsEst. cost / yrCompare
Panasonic U-60PZ3R5 / S-6071PF3E5.7 kW heating5.7 kW cooling2,135 kWh/yr3$705
Gree GUD50W1/NhC-S / GUD50PHS1/C-S5.8 kW heating5.3 kW cooling2,138 kWh/yr3.5$706
Panasonic U-60PZ4R5 / S-6071PF3E5.7 kW heating5.7 kW cooling2,172 kWh/yr3$717
Carrier 38QSM053D8S/42QSM053D8S5.7 kW heating5.3 kW cooling2,338 kWh/yr3.5$772
Carrier 38QSM060D8S/42QSM060D8S6.5 kW heating5.8 kW cooling2,518 kWh/yr3.5$831

Heat pumps similar to the Panasonic U-60PZ3R5

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
Mitsubishi Electric SUZ-M60VAD2-A/PEAD-M60JAA7 kW heating6 kW cooling2,879 kWh/yr3$950
Hitachi PAS-2.5UFASNQ1 / PPIM-2.5UFA1NQ7.5 kW heating6 kW cooling3,218 kWh/yr3$1,062
Daikin RZAC60GV1 / FDYBA60AV17 kW heating6 kW cooling2,674 kWh/yr2.5$882
Mitsubishi Electric SUZ-M60VAD2-A/PEAD-M60JAA(D) Series7 kW heating6 kW cooling2,879 kWh/yr3$950
Daikin RZAC60GBV1 / FDYBA60AV17 kW heating6 kW cooling2,674 kWh/yr2.5$882
Carrier 38QSM060D8S/42QSM060D8S6.5 kW heating5.8 kW cooling2,518 kWh/yr3.5$831

Other Panasonic models of similar capacity

ModelStarsEst. cost / yrCompare
Panasonic U-60PZ4R5 / S-60PE4R6 kW heating6 kW cooling2,446 kWh/yr2.5$807
Panasonic U-60PZ3R5 / S-6071PF3E5.7 kW heating5.7 kW cooling2,135 kWh/yr3$705

Compare U-60PZ3R5/S-60PE3R with another model

Panasonic U-60PZ3R5 specifications

Type
Reverse cycle
Configuration
Split system
Air distribution
Ducted
Indoor unit
–
Rated cooling capacity (35 Β°C)
6.00 kW
Cooling power input
1.84 kW
Rated heating capacity (7 Β°C)
6.00 kW
Heating power input
1.47 kW
EER, full load (tested)
3.24
COP, full load (tested)
4.06
Rated AEER
3.20
Rated ACOP
3.98
Standby power (PIA)
11.0 W
Compressor
Variable speed, Inverter
Refrigerant
R32
Power supply
Single phase
Indoor sound power
–
Outdoor sound power
–
Demand response (AS/NZS 4755)
Yes (mode 1 on off, mode 2 50 percent, mode 3 75 percent)
Dimensions (WΓ—HΓ—D)
1000 Γ— 290 Γ— 700 mm
Country of manufacture
Malaysia

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

Panasonic U-60PZ3R5 zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––978761
Coldresidential2.02.04462,205
Mixedcommercial––1,217424
Mixedresidential2.02.0683868
Hotcommercial––2,625104
Hotresidential2.02.01,948155
Part-load test points (22 values)
h__h1_min_cap_power_rated
480 W
h__h2_ext_cap_power_rated
1900 W
c__t1_half_cap_power_rated
750 W
c__t1_have_min_cap_results
No
h__h1_half_cap_power_rated
650 W
h__h1_have_min_cap_results
Yes
h__h3_have_ext_cap_results
No
h__h2_have_full_cap_results
No
h__h2_have_half_cap_results
No
h__h3_have_full_cap_results
No
h__h3_have_half_cap_results
No
h__h1_min_cap_heat_cap_rated
1800 W
h__h2_ext_cap_heat_cap_rated
5700 W
h__h1_half_cap_heat_cap_rated
3000 W
h__h2_is_capable_extended_load
Yes
c__low_temp_min_cap_power_rated
450 W
c__low_temp_half_cap_power_rated
650 W
c__low_temp_have_min_cap_results
Yes
c__t1_half_cap_cooling_cap_rated
3000 W
c__low_temp_have_half_cap_results
Yes
c__low_temp_min_cap_cooling_cap_rated
1780 W
c__low_temp_half_cap_cooling_cap_rated
3000 W

New Zealand E3 registration details

Registration number
AAC9598
GEMS registration id
174279
Status
approved, available (self-reported)
Registration expires
1 December 2030
Registered for sale in
Australia, New Zealand
Family
–
Regulatory standard
[SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
Test standard
AS/NZS 3823.1.2:2012
MEPS
2019
Product class
Class 10

Source: E3 programme registration data (EECA, New Zealand) (trans-Tasman E3 registration data published by DCCEEW on data.gov.au, CC BY 3.0 AU). Dataset published 19 September 2026; last checked 20 September 2026. How the derived figures are calculated.