New Zealand Β· costs in NZD

Reverse cycle split system air conditioner
Reclaim Energy CA-D160D1HWH-ODU/CA-D160D1HWH-IDU Heat Pump
Reclaim Energy CA-D160D1HWH-ODU/CA-D160D1HWH-IDU is a 16 kW reverse cycle ducted split system heat pump registered for sale in New Zealand under the trans-Tasman E3 energy rating scheme (registration AAC10309).
- Energy rating (cooling)
- 3
- Heating: 2
- Annual electricity use
- 7,939 kWh
- 927 cooling + 7,012 heating
- Estimated running cost
- $2,620 / year
- $218 / month Β· $26,199 over 10 years
- Capacity
- 16 kW cooling
- 19.5 kW heating
About the same electricity as the median of 71 comparable 16 kW reverse cycle ducted split system registrations (7,959 kWh a year) in the cold zone. Uses less than 52% of them.
Across all 3,611 air conditioner registrations sold in Australia, it uses less than 19% (this compares very different sizes, so the cohort figure above is the useful one).
Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ 33c/kWh in NZD; change the price above to your tariff.
Reclaim Energy running cost by climate zone
| Climate zone | kWh / year | Per year | 10 years |
|---|---|---|---|
| Cold zone | 7,939 | $2,620 | $26,199 |
| Mixed zone | 4,074 | $1,344 | $13,444 |
| Hot zone | 4,712 | $1,555 | $15,550 |
At 33c/kWh. Formula: cost = annual kWh Γ price. The kWh figure is the labelβs residential estimate for that zone; commercial-profile figures are in the specifications.
Heat pumps that use less electricity
Same configuration and type, cooling capacity within 12% of 16 kW, at least 3% lower annual kWh in the cold zone.
| Model | Stars | Est. cost / yr | Compare |
|---|---|---|---|
| Daikin RZA160CV1 / FDYAN160AV118 kW heating15.5 kW cooling4,493 kWh/yr | 2 | $1,483 | |
| Actron Air CRV15BT / EAA15BS & EFV15BS15 kW heating14.8 kW cooling6,561 kWh/yr | 2.5 | $2,165 | |
| Actron Air CRV15BT / EVV15BS15 kW heating14.8 kW cooling6,561 kWh/yr | 2.5 | $2,165 | |
| Carrier 38QSH170D8S / 42QSH170D8S17 kW heating17 kW cooling6,907 kWh/yr | 3.5 | $2,279 | |
| Hisense AUW-140U4RH1/AUD-140UX4RSH117 kW heating14.5 kW cooling6,926 kWh/yr | 3 | $2,286 |
Heat pumps similar to the Reclaim Energy
Technically comparable registrations: same configuration and type, capacity within 12%.
| Model | Stars | Est. cost / yr | Compare |
|---|---|---|---|
| Gree GUD160W1/NhC-S / GUD160PHS1/C-S18 kW heating16 kW cooling7,395 kWh/yr | 3.5 | $2,440 | |
| Braemar KCHB160D1B/KDHB160D1S18 kW heating16 kW cooling7,460 kWh/yr | 3.5 | $2,462 | |
| Mitsubishi Electric PUZ-ZM160VKA-A / PEA-M160HAA218 kW heating16 kW cooling7,459 kWh/yr | 3 | $2,461 | |
| Panasonic U-160PZH3R5 / S-160PE4*18 kW heating16 kW cooling7,357 kWh/yr | 2.5 | $2,428 | |
| Mitsubishi Electric PUZ-ZM160VKA-A / PEA-M160HAA18 kW heating16 kW cooling7,459 kWh/yr | 3 | $2,461 | |
| Panasonic U-160PZH3R8 / S-160PE4RA18 kW heating16 kW cooling7,357 kWh/yr | 2.5 | $2,428 | |
| TECO TDS-TSO160HVSWDG18 kW heating16 kW cooling7,395 kWh/yr | 3.5 | $2,440 | |
| Braemar KCHA160D1B/KDHA160D1S18 kW heating16 kW cooling7,395 kWh/yr | 3.5 | $2,440 |
Compare CA-D160D1HWH-ODU/CA-D160D1HWH-IDU with another model
Reclaim Energy specifications
- Type
- Reverse cycle
- Configuration
- Split system
- Air distribution
- Ducted
- Indoor unit
- β
- Rated cooling capacity (35 Β°C)
- 16.00 kW
- Cooling power input
- 4.86 kW
- Rated heating capacity (7 Β°C)
- 19.50 kW
- Heating power input
- 5.10 kW
- EER, full load (tested)
- 3.36
- COP, full load (tested)
- 3.81
- Rated AEER
- 3.28
- Rated ACOP
- 3.81
- Standby power (PIA)
- 6.0 W
- Compressor
- Variable speed, Inverter
- Refrigerant
- R32
- Power supply
- Single phase
- Indoor sound power
- β
- Outdoor sound power
- 74 dB(A)
- Demand response (AS/NZS 4755)
- Yes
- Country of manufacture
- China
Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.
Reclaim Energy zoned energy rating figures
As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.
| Zone | Profile | Cooling stars | Heating stars | Cooling kWh | Heating kWh |
|---|---|---|---|---|---|
| Coldcommercial | commercial | β | β | 1,784 | 2,232 |
| Coldresidential | residential | 3.0 | 2.0 | 927 | 7,012 |
| Mixedcommercial | commercial | β | β | 2,399 | 1,157 |
| Mixedresidential | residential | 3.0 | 2.5 | 1,471 | 2,603 |
| Hotcommercial | commercial | β | β | 5,582 | 238 |
| Hotresidential | residential | 3.0 | 3.0 | 4,335 | 377 |
Part-load test points (18 values)
- h__h2_ext_cap_power_rated
- 5800 W
- c__t1_half_cap_power_rated
- 1780 W
- c__t1_have_min_cap_results
- No
- h__h1_half_cap_power_rated
- 1980 W
- h__h1_have_min_cap_results
- No
- h__h3_have_ext_cap_results
- No
- h__h2_have_full_cap_results
- No
- h__h2_have_half_cap_results
- No
- h__h3_have_full_cap_results
- No
- h__h3_have_half_cap_results
- No
- h__h2_ext_cap_heat_cap_rated
- 17300 W
- h__h1_half_cap_heat_cap_rated
- 9750 W
- h__h2_is_capable_extended_load
- Yes
- c__low_temp_half_cap_power_rated
- 1400 W
- c__low_temp_have_min_cap_results
- No
- c__t1_half_cap_cooling_cap_rated
- 8000 W
- c__low_temp_have_half_cap_results
- Yes
- c__low_temp_half_cap_cooling_cap_rated
- 8000 W
New Zealand E3 registration details
- Registration number
- AAC10309
- GEMS registration id
- 180944
- Status
- approved, available (self-reported)
- Registration expires
- 21 July 2031
- Registered for sale in
- Australia, Fiji, New Zealand
- Family
- β
- Regulatory standard
- [SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
- Test standard
- AS/NZS 3823.1.2:2012
- MEPS
- 2019
- Product class
- Class 11
Source: E3 programme registration data (EECA, New Zealand) (trans-Tasman E3 registration data published by DCCEEW on data.gov.au, CC BY 3.0 AU). Dataset published 25 September 2026; last checked 26 September 2026. Manufacturer: apricus.com.au. How the derived figures are calculated.