c/kWh
Energy rating (cooling)
4
Heating: 2.5
Annual electricity use
3,457 kWh
395 cooling + 3,062 heating
Estimated running cost
$1,141 / year
$95 / month Β· $11,408 over 10 years
Capacity
9 kW cooling
9.3 kW heating

20% less electricity than the median of 9 comparable 10 kW reverse cycle fixed registrations (4,344 kWh a year) in the cold zone. Uses less than 89% of them.

Across all 3,611 air conditioner registrations sold in Australia, it uses less than 54% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ— 33c/kWh in NZD; change the price above to your tariff.

Rinnai MON4H09B running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 3,457$1,141$11,408
Mixed zone 1,746$576$5,762
Hot zone 1,881$621$6,207

At 33c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Heat pumps that use less electricity

Same configuration and type, cooling capacity within 12% of 9 kW, at least 3% lower annual kWh in the cold zone.

ModelStarsEst. cost / yrCompare
Haier 4U80S2PR1FA8 kW heating8 kW cooling3,093 kWh/yr3.5$1,021

Heat pumps similar to the Rinnai MON4H09B

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
Hitachi RAM-G85N5HCE10 kW heating8.5 kW cooling4,059 kWh/yr3.5$1,339
Braemar NCHV08D14B8.8 kW heating8.2 kW cooling3,440 kWh/yr3.5$1,135
Daikin 4MXM80RVMA9.6 kW heating8 kW cooling3,740 kWh/yr3$1,234
Hitachi RAM-G110N5HCE12 kW heating10 kW cooling4,580 kWh/yr4$1,511
Haier 4U80S2PR1FA8 kW heating8 kW cooling3,093 kWh/yr3.5$1,021
Daikin 4MXM80R2VMA9.6 kW heating8 kW cooling3,740 kWh/yr3$1,234
Haier 5U100S2PS1FA10 kW heating10 kW cooling4,081 kWh/yr3.5$1,347

Other Rinnai models of similar capacity

ModelStarsEst. cost / yrCompare
Rinnai MON4H09B1LA9.5 kW heating9 kW cooling3,592 kWh/yr4$1,185

Compare MON4H09B with another model

Rinnai MON4H09B specifications

Type
Reverse cycle
Configuration
Fixed
Air distribution
Ducted or non-ducted
Indoor unit
–
Rated cooling capacity (35 Β°C)
9.00 kW
Cooling power input
2.07 kW
Rated heating capacity (7 Β°C)
9.30 kW
Heating power input
2.07 kW
EER, full load (tested)
4.18
COP, full load (tested)
4.49
Rated AEER
4.24
Rated ACOP
4.38
Standby power (PIA)
16.2 W
Compressor
Variable speed, Inverter
Refrigerant
R32
Power supply
Single phase
Indoor sound power
–
Outdoor sound power
68.4 dB(A)
Demand response (AS/NZS 4755)
Yes
Country of manufacture
China

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

Rinnai MON4H09B zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––269982
Coldresidential4.02.53953,062
Mixedcommercial––1,139517
Mixedresidential4.03.06051,141
Hotcommercial––1,711128
Hotresidential5.03.51,689192
Part-load test points (25 values)
c__t1_min_cap_power_rated
650 W
h__h1_min_cap_power_rated
480 W
h__h2_ext_cap_power_rated
2400 W
c__t1_half_cap_power_rated
930 W
c__t1_have_min_cap_results
Yes
h__h1_half_cap_power_rated
910 W
h__h1_have_min_cap_results
Yes
h__h3_have_ext_cap_results
No
h__h2_have_full_cap_results
No
h__h2_have_half_cap_results
No
h__h3_have_full_cap_results
No
h__h3_have_half_cap_results
No
h__h1_min_cap_heat_cap_rated
2500 W
h__h2_ext_cap_heat_cap_rated
8000 W
h__h1_half_cap_heat_cap_rated
4800 W
h__h2_is_capable_extended_load
Yes
c__low_temp_min_cap_power_rated
340 W
c__t1_min_cap_cooling_cap_rated
3270 W
c__low_temp_full_cap_power_rated
1891.98 W
c__low_temp_half_cap_power_rated
630 W
c__t1_half_cap_cooling_cap_rated
4750 W
c__low_temp_have_half_cap_results
Yes
c__low_temp_min_cap_cooling_cap_rated
2900 W
c__low_temp_full_cap_cooling_cap_rated
9693 W
c__low_temp_half_cap_cooling_cap_rated
4700 W

3 model numbers on 3 other registrations. Variants registered separately can carry different star ratings and energy figures; check the registration number on the label.

ModelRegistrationStarskWh / yr
MON4H09BAAC686143,582
MON4H09B1LAAAC908343,592
MON4H09BNZZAC083243,521

New Zealand E3 registration details

Registration number
AAC8090
GEMS registration id
159986
Status
approved, available (self-reported)
Registration expires
11 March 2029
Registered for sale in
Australia, Fiji, New Zealand
Family
–
Regulatory standard
[SEER Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
Test standard
AS/NZS 3823.1.4:2012
MEPS
2019
Product class
Class 19

Source: E3 programme registration data (EECA, New Zealand) (trans-Tasman E3 registration data published by DCCEEW on data.gov.au, CC BY 3.0 AU). Dataset published 25 September 2026; last checked 26 September 2026. Manufacturer: rinnai.com.au. How the derived figures are calculated.