c/kWh
Energy rating (cooling)
4
Heating: 2
Annual electricity use
3,592 kWh
412 cooling + 3,180 heating
Estimated running cost
$1,185 / year
$99 / month Β· $11,854 over 10 years
Capacity
9 kW cooling
9.5 kW heating

17% less electricity than the median of 9 comparable 10 kW reverse cycle fixed registrations (4,344 kWh a year) in the cold zone. Uses less than 78% of them.

Across all 3,612 air conditioner registrations sold in Australia, it uses less than 52% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ— 33c/kWh in NZD; change the price above to your tariff.

Rinnai MON4H09B1LA running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 3,592$1,185$11,854
Mixed zone 1,834$605$6,052
Hot zone 2,028$669$6,692

At 33c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Heat pumps that use less electricity

Same configuration and type, cooling capacity within 12% of 9 kW, at least 3% lower annual kWh in the cold zone.

ModelStarsEst. cost / yrCompare
Haier 4U80S2PR1FA8 kW heating8 kW cooling3,093 kWh/yr3.5$1,021
Braemar NCHV08D14B8.8 kW heating8.2 kW cooling3,440 kWh/yr3.5$1,135
Rinnai MON4H09B9.3 kW heating9 kW cooling3,457 kWh/yr4$1,141

Heat pumps similar to the Rinnai MON4H09B1LA

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
Hitachi RAM-G85N5HCE10 kW heating8.5 kW cooling4,059 kWh/yr3.5$1,339
Braemar NCHV08D14B8.8 kW heating8.2 kW cooling3,440 kWh/yr3.5$1,135
Haier 4U80S2PR1FA8 kW heating8 kW cooling3,093 kWh/yr3.5$1,021
Hitachi RAM-G110N5HCE12 kW heating10 kW cooling4,580 kWh/yr4$1,511
Daikin 4MXM80RVMA9.6 kW heating8 kW cooling3,740 kWh/yr3$1,234
Haier 5U100S2PS1FA10 kW heating10 kW cooling4,081 kWh/yr3.5$1,347
Daikin 4MXM80R2VMA9.6 kW heating8 kW cooling3,740 kWh/yr3$1,234

Other Rinnai models of similar capacity

ModelStarsEst. cost / yrCompare
Rinnai MON4H09B9.3 kW heating9 kW cooling3,457 kWh/yr4$1,141

Compare MON4H09B1LA with another model

Rinnai MON4H09B1LA specifications

Type
Reverse cycle
Configuration
Fixed
Air distribution
Ducted or non-ducted
Indoor unit
–
Rated cooling capacity (35 Β°C)
9.00 kW
Cooling power input
2.38 kW
Rated heating capacity (7 Β°C)
9.50 kW
Heating power input
2.32 kW
EER, full load (tested)
3.93
COP, full load (tested)
4.27
Rated AEER
3.70
Rated ACOP
4.01
Standby power (PIA)
13.8 W
Compressor
Variable speed, Inverter
Refrigerant
R32
Power supply
Single phase
Indoor sound power
–
Outdoor sound power
67.6 dB(A)
Demand response (AS/NZS 4755)
Yes
Country of manufacture
China

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

Rinnai MON4H09B1LA zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––6271,022
Coldresidential4.02.04123,180
Mixedcommercial––890540
Mixedresidential4.03.06521,182
Hotcommercial––2,235128
Hotresidential4.53.51,835193
Part-load test points (23 values)
c__t1_min_cap_power_rated
495 W
h__h1_min_cap_power_rated
425 W
h__h2_ext_cap_power_rated
2490 W
c__t1_half_cap_power_rated
790 W
c__t1_have_min_cap_results
Yes
h__h1_half_cap_power_rated
860 W
h__h1_have_min_cap_results
Yes
h__h3_have_ext_cap_results
No
h__h2_have_full_cap_results
No
h__h2_have_half_cap_results
No
h__h3_have_full_cap_results
No
h__h3_have_half_cap_results
No
h__h1_min_cap_heat_cap_rated
2020 W
h__h2_ext_cap_heat_cap_rated
8200 W
h__h1_half_cap_heat_cap_rated
4740 W
h__h2_is_capable_extended_load
Yes
c__low_temp_min_cap_power_rated
365 W
c__t1_min_cap_cooling_cap_rated
2700 W
c__low_temp_half_cap_power_rated
630 W
c__t1_half_cap_cooling_cap_rated
4300 W
c__low_temp_have_half_cap_results
Yes
c__low_temp_min_cap_cooling_cap_rated
3390 W
c__low_temp_half_cap_cooling_cap_rated
4900 W

New Zealand E3 registration details

Registration number
AAC9083
GEMS registration id
170858
Status
approved, available (self-reported)
Registration expires
9 July 2030
Registered for sale in
Australia, New Zealand
Family
–
Regulatory standard
[SEER Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
Test standard
AS/NZS 3823.1.4:2012
MEPS
2019
Product class
Class 19

Source: E3 programme registration data (EECA, New Zealand) (trans-Tasman E3 registration data published by DCCEEW on data.gov.au, CC BY 3.0 AU). Dataset published 25 September 2026; last checked 26 September 2026. Manufacturer: rinnai.com.au. How the derived figures are calculated.