c/kWh
Energy rating (cooling)
3.5
Heating: 2.5
Annual electricity use
5,055 kWh
681 cooling + 4,374 heating
Estimated running cost
$1,668 / year
$139 / month Β· $16,682 over 10 years
Capacity
13.5 kW cooling
14 kW heating

22% less electricity than the median of 21 comparable 14 kW reverse cycle registrations (6,470 kWh a year) in the cold zone. Uses less than 91% of them.

Across all 3,566 air conditioner registrations sold in Australia, it uses less than 38% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ— 33c/kWh in NZD; change the price above to your tariff.

Rinnai MON5H14B1LA running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 5,055$1,668$16,682
Mixed zone 2,758$910$9,101
Hot zone 3,370$1,112$11,121

At 33c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Heat pumps that use less electricity

Same configuration and type, cooling capacity within 12% of 13.5 kW, at least 3% lower annual kWh in the cold zone.

ModelStarsEst. cost / yrCompare
Panasonic U-4LE2R812.5 kW heating12.1 kW cooling4,059 kWh/yr3$1,339
Panasonic U-4LE2R8E12.5 kW heating12.1 kW cooling4,059 kWh/yr3$1,339
Haier 5U125S2PN1FA12.2 kW heating12.2 kW cooling4,758 kWh/yr3.5$1,570
Braemar NCHV12D15B12.6 kW heating12.3 kW cooling4,771 kWh/yr3.5$1,574
Rinnai MON5H13B13.5 kW heating13 kW cooling4,793 kWh/yr3.5$1,582

Heat pumps similar to the Rinnai MON5H14B1LA

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
Midea MDV-V140WN8(AUN)17 kW heating14 kW cooling5,810 kWh/yr4$1,917
Mitsubishi Electric PUMY-SP125VKMD3-A-BS16 kW heating14 kW cooling6,470 kWh/yr2.5$2,135
Panasonic U-5LZ2E516 kW heating14 kW cooling5,357 kWh/yr2.5$1,768
Mitsubishi Heavy Industries FDC140KXZES114 kW heating14 kW cooling6,331 kWh/yr2$2,089
Mitsubishi Electric PUMY-SP125YKMD3-A16 kW heating14 kW cooling6,470 kWh/yr2.5$2,135
Panasonic U-5LZ2E816 kW heating14 kW cooling5,357 kWh/yr2.5$1,768
Daikin RSUYA5AVM16 kW heating14 kW cooling4,941 kWh/yr3$1,631
Mitsubishi Heavy Industries FDCS140KXZES114 kW heating14 kW cooling6,331 kWh/yr2$2,089

Compare MON5H14B1LA with another model

Rinnai MON5H14B1LA specifications

Type
Reverse cycle
Configuration
–
Air distribution
Ducted or non-ducted
Indoor unit
–
Rated cooling capacity (35 Β°C)
13.50 kW
Cooling power input
–
Rated heating capacity (7 Β°C)
14.00 kW
Heating power input
–
EER, full load (tested)
3.47
COP, full load (tested)
4.39
Rated AEER
3.40
Rated ACOP
4.23
Standby power (PIA)
16.6 W
Compressor
Variable speed, Inverter
Refrigerant
R32
Power supply
Single phase
Indoor sound power
–
Outdoor sound power
69.9 dB(A)
Demand response (AS/NZS 4755)
Yes
Country of manufacture
China

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

Rinnai MON5H14B1LA zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––1,1671,391
Coldresidential3.52.56814,374
Mixedcommercial––1,617740
Mixedresidential3.53.01,0881,670
Hotcommercial––3,889172
Hotresidential4.03.53,107263
Part-load test points (23 values)
c__t1_min_cap_power_rated
827 W
h__h1_min_cap_power_rated
702 W
h__h2_ext_cap_power_rated
4915 W
c__t1_half_cap_power_rated
1343 W
c__t1_have_min_cap_results
Yes
h__h1_half_cap_power_rated
1311 W
h__h1_have_min_cap_results
Yes
h__h3_have_ext_cap_results
No
h__h2_have_full_cap_results
No
h__h2_have_half_cap_results
No
h__h3_have_full_cap_results
No
h__h3_have_half_cap_results
No
h__h1_min_cap_heat_cap_rated
3840 W
h__h2_ext_cap_heat_cap_rated
14744 W
h__h1_half_cap_heat_cap_rated
7030 W
h__h2_is_capable_extended_load
Yes
c__low_temp_min_cap_power_rated
628 W
c__t1_min_cap_cooling_cap_rated
4575 W
c__low_temp_half_cap_power_rated
1035 W
c__t1_half_cap_cooling_cap_rated
7260 W
c__low_temp_have_half_cap_results
Yes
c__low_temp_min_cap_cooling_cap_rated
4670 W
c__low_temp_half_cap_cooling_cap_rated
7380 W

New Zealand E3 registration details

Registration number
AAC9075
GEMS registration id
–
Status
approved
Registration expires
9 July 2030
Registered for sale in
Australia, New Zealand
Family
–
Regulatory standard
Greenhouse and Energy Minimum Standards (Air Conditioners up to 65kW) Determination 2019
Test standard
AS/NZS 3823.1.4:2012
MEPS
2019
Product class
20

Source: E3 programme registration data (EECA, New Zealand) (trans-Tasman E3 registration data published by DCCEEW on data.gov.au, CC BY 3.0 AU). Dataset published 28 October 2026; last checked 29 October 2026. How the derived figures are calculated.