c/kWh
Energy rating (cooling)
6.5
Heating: 3.5
Annual electricity use
805 kWh
92 cooling + 713 heating
Estimated running cost
$266 / year
$22 / month Β· $2,657 over 10 years
Capacity
2.8 kW cooling
2.9 kW heating

25% less electricity than the median of 177 comparable 2.5 kW reverse cycle split system registrations (1,073 kWh a year) in the cold zone. Uses less than 95% of them.

Across all 3,611 air conditioner registrations sold in Australia, it uses less than 91% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ— 33c/kWh in NZD; change the price above to your tariff.

Spt AW028C-1 running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 805$266$2,657
Mixed zone 421$139$1,389
Hot zone 462$152$1,525

At 33c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Heat pumps that use less electricity

Same configuration and type, cooling capacity within 12% of 2.8 kW, at least 3% lower annual kWh in the cold zone.

ModelStarsEst. cost / yrCompare
Hitachi RAC-VJ25NHAE/RAI-VJ25RHAE3.5 kW heating2.5 kW cooling653 kWh/yr4$215
Midea MFEP26VA-W/MFEP26VA-N2.7 kW heating2.6 kW cooling776 kWh/yr6.5$256

Heat pumps similar to the Spt AW028C-1

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
Smart User SUFA26R2.6 kW heating2.8 kW cooling847 kWh/yr5$280
TCL TAC-09CHSD/VEIH2.6 kW heating2.8 kW cooling847 kWh/yr5$280
Ers Tech ERS-AC28F012.6 kW heating2.8 kW cooling847 kWh/yr5$280
Braemar TCHV25T1S/TSHV25T1S2.6 kW heating2.8 kW cooling847 kWh/yr5$280
TCL TAC-09CHSD/VEIH2.6 kW heating2.8 kW cooling847 kWh/yr5$280
Comfee CASG-XG25/CASN-XG252.8 kW heating2.7 kW cooling956 kWh/yr5.5$315
Gree GWH09AGCXB-K6DNA1B2.9 kW heating2.7 kW cooling1,004 kWh/yr4.5$331
Gree GWH09AGCXB-K6DNA1B/O / GWH09AGCXB-K6DNA1B/I2.9 kW heating2.7 kW cooling1,004 kWh/yr4.5$331

Compare AW028C-1 / AW028E with another model

Spt AW028C-1 specifications

Type
Reverse cycle
Configuration
Split system
Air distribution
Non-ducted
Indoor unit
Wall hung
Rated cooling capacity (35 Β°C)
2.80 kW
Cooling power input
0.51 kW
Rated heating capacity (7 Β°C)
2.85 kW
Heating power input
0.51 kW
EER, full load (tested)
5.04
COP, full load (tested)
5.16
Rated AEER
5.45
Rated ACOP
5.55
Standby power (PIA)
1.0 W
Compressor
Variable speed, Inverter
Refrigerant
R32
Power supply
Single phase
Indoor sound power
55.3 dB(A)
Outdoor sound power
57.8 dB(A)
Demand response (AS/NZS 4755)
Yes
Country of manufacture
China

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

Spt AW028C-1 zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––107232
Coldresidential6.53.592713
Mixedcommercial––183125
Mixedresidential6.54.0145276
Hotcommercial––48327
Hotresidential7.04.542141
Part-load test points (25 values)
c__t1_min_cap_power_rated
180 W
h__h1_min_cap_power_rated
160 W
h__h2_ext_cap_power_rated
1050 W
c__t1_half_cap_power_rated
220 W
c__t1_have_min_cap_results
Yes
h__h1_half_cap_power_rated
220 W
h__h1_have_min_cap_results
Yes
h__h3_have_ext_cap_results
No
h__h2_have_full_cap_results
No
h__h2_have_half_cap_results
No
h__h3_have_full_cap_results
No
h__h3_have_half_cap_results
No
h__h1_min_cap_heat_cap_rated
1020 W
h__h2_ext_cap_heat_cap_rated
3500 W
h__h1_half_cap_heat_cap_rated
1410 W
h__h2_is_capable_extended_load
Yes
c__low_temp_min_cap_power_rated
110 W
c__t1_min_cap_cooling_cap_rated
980 W
c__low_temp_full_cap_power_rated
466.14000000000004 W
c__low_temp_half_cap_power_rated
150 W
c__t1_half_cap_cooling_cap_rated
1300 W
c__low_temp_have_half_cap_results
Yes
c__low_temp_min_cap_cooling_cap_rated
1040 W
c__low_temp_full_cap_cooling_cap_rated
3015.6 W
c__low_temp_half_cap_cooling_cap_rated
1400 W

New Zealand E3 registration details

Registration number
AAC7926
GEMS registration id
158127
Status
approved, available (self-reported)
Registration expires
3 December 2028
Registered for sale in
Australia, Fiji, New Zealand
Family
–
Regulatory standard
[SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
Test standard
AS/NZS 3823.1.1:2012
MEPS
2019
Product class
Class 8

Source: E3 programme registration data (EECA, New Zealand) (trans-Tasman E3 registration data published by DCCEEW on data.gov.au, CC BY 3.0 AU). Dataset published 19 September 2026; last checked 20 September 2026. How the derived figures are calculated.