c/kWh
Energy rating (cooling)
2.5
Heating: 1
Annual electricity use
5,478 kWh
639 cooling + 4,839 heating
Estimated running cost
$1,808 / year
$151 / month Β· $18,077 over 10 years
Capacity
10.5 kW cooling
10.5 kW heating

21% more electricity than the median of 26 comparable 10 kW reverse cycle fixed registrations (4,539 kWh a year) in the cold zone. Uses less than 4% of them.

Across all 3,611 air conditioner registrations sold in Australia, it uses less than 35% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ— 33c/kWh in NZD; change the price above to your tariff.

TCL FMA-36I4HD running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 5,478$1,808$18,077
Mixed zone 2,747$907$9,065
Hot zone 3,141$1,037$10,365

At 33c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Heat pumps that use less electricity

Same configuration and type, cooling capacity within 12% of 10.5 kW, at least 3% lower annual kWh in the cold zone.

ModelStarsEst. cost / yrCompare
Actron Air MRC-100CS-49.5 kW heating9.4 kW cooling3,543 kWh/yr4$1,169
Mitsubishi Electric MXZ-5F100VGD10 kW heating10 kW cooling3,703 kWh/yr3.5$1,222
Fujitsu AOTG36LBLA512 kW heating10 kW cooling4,079 kWh/yr3.5$1,346
Fujitsu AOTH36KBTA512 kW heating10 kW cooling4,088 kWh/yr4$1,349
Daikin 5MXM100RVMA11 kW heating10 kW cooling4,337 kWh/yr3$1,431

Heat pumps similar to the TCL FMA-36I4HD

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
Hisense AMW4-100U4RQA11.1 kW heating10.5 kW cooling4,380 kWh/yr3$1,445
Midea MULMI0511B/MFAG20N11 kW heating10.5 kW cooling4,722 kWh/yr3$1,558
Midea MULMI0511B11 kW heating10.5 kW cooling4,536 kWh/yr3$1,497
Hisense AMW4-100U4RQA/AST-09UW4RMETD0111.1 kW heating10.5 kW cooling4,380 kWh/yr3$1,445
TECO TSOM106HVAG411.4 kW heating10.6 kW cooling4,364 kWh/yr3.5$1,440
Hyundai HYSMHS10OT*12.3 kW heating10.7 kW cooling4,935 kWh/yr3$1,629
Hyundai HYSMHS10OTC12.3 kW heating10.7 kW cooling4,935 kWh/yr3$1,629
Carrier 38QUM105D8S511 kW heating10.7 kW cooling4,608 kWh/yr3$1,521

Compare FMA-36I4HD/DVO with another model

TCL FMA-36I4HD specifications

Type
Reverse cycle
Configuration
Fixed
Air distribution
Non-ducted
Indoor unit
–
Rated cooling capacity (35 Β°C)
10.50 kW
Cooling power input
3.15 kW
Rated heating capacity (7 Β°C)
10.50 kW
Heating power input
3.08 kW
EER, full load (tested)
3.35
COP, full load (tested)
3.40
Rated AEER
3.29
Rated ACOP
3.37
Standby power (PIA)
11.8 W
Compressor
Variable speed, Inverter
Refrigerant
R410A
Power supply
Single phase
Indoor sound power
–
Outdoor sound power
72 dB(A)
Demand response (AS/NZS 4755)
Yes
Country of manufacture
China

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

TCL FMA-36I4HD zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––1,3641,426
Coldresidential2.51.06394,839
Mixedcommercial––1,726719
Mixedresidential2.51.51,0041,743
Hotcommercial––3,875149
Hotresidential3.02.52,909232
Part-load test points (18 values)
c__t1_half_cap_power_rated
1020 W
c__t1_have_min_cap_results
No
h__h1_half_cap_power_rated
1120 W
h__h1_have_min_cap_results
No
h__h2_full_cap_power_rated
3420 W
h__h2_have_half_cap_results
No
h__h3_have_full_cap_results
No
h__h3_have_half_cap_results
No
h__h1_half_cap_heat_cap_rated
5450 W
h__h2_full_cap_heat_cap_rated
7400 W
h__h2_is_capable_extended_load
No
c__low_temp_full_cap_power_rated
2879.1 W
c__low_temp_half_cap_power_rated
932.2800000000001 W
c__low_temp_have_min_cap_results
No
c__t1_half_cap_cooling_cap_rated
5030 W
c__low_temp_have_half_cap_results
No
c__low_temp_full_cap_cooling_cap_rated
11308.5 W
c__low_temp_half_cap_cooling_cap_rated
5417.3099999999995 W

New Zealand E3 registration details

Registration number
AAC7523
GEMS registration id
154173
Status
approved, available (self-reported)
Registration expires
22 May 2028
Registered for sale in
Australia, Fiji, New Zealand
Family
–
Regulatory standard
[SEER Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
Test standard
AS/NZS 3823.1.4:2012
MEPS
2019
Product class
Class 20

Source: E3 programme registration data (EECA, New Zealand) (trans-Tasman E3 registration data published by DCCEEW on data.gov.au, CC BY 3.0 AU). Dataset published 19 September 2026; last checked 20 September 2026. How the derived figures are calculated.