c/kWh
Energy rating (cooling)
4.5
Heating: 2.5
Annual electricity use
1,118 kWh
113 cooling + 1,005 heating
Estimated running cost
$369 / year
$31 / month Β· $3,689 over 10 years
Capacity
2.6 kW cooling
3.3 kW heating

4% more electricity than the median of 177 comparable 2.5 kW reverse cycle split system registrations (1,073 kWh a year) in the cold zone. Uses less than 38% of them.

Across all 3,611 air conditioner registrations sold in Australia, it uses less than 87% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ— 33c/kWh in NZD; change the price above to your tariff.

TCL TAC-10CHSD running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 1,118$369$3,689
Mixed zone 567$187$1,871
Hot zone 548$181$1,808

At 33c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Heat pumps that use less electricity

Same configuration and type, cooling capacity within 12% of 2.6 kW, at least 3% lower annual kWh in the cold zone.

ModelStarsEst. cost / yrCompare
Hitachi RAC-VJ25NHAE/RAI-VJ25RHAE3.5 kW heating2.5 kW cooling653 kWh/yr4$215
Midea MFEP26VA-W/MFEP26VA-N2.7 kW heating2.6 kW cooling776 kWh/yr6.5$256
Midea MFEP26VB-W/MFEP26VB-N2.7 kW heating2.6 kW cooling790 kWh/yr7$261
Actron Air WRC-026DS / WRE-026DS2.7 kW heating2.6 kW cooling790 kWh/yr7$261
Actron Air WRC-026CS / WRE-026CS2.8 kW heating2.6 kW cooling804 kWh/yr7$265

Heat pumps similar to the TCL TAC-10CHSD

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
TECO TWS-TSO26H3DVHA2.9 kW heating2.6 kW cooling1,011 kWh/yr5.5$334
Akai AK-TP26M2.9 kW heating2.6 kW cooling1,011 kWh/yr5.5$334
Hyundai HYSSSAC26TD3.3 kW heating2.6 kW cooling1,108 kWh/yr5$366
Hyundai HYSSSAC26T*3.3 kW heating2.6 kW cooling1,108 kWh/yr5$366
Aux ASW-H27A4/FAR3DI2.9 kW heating2.6 kW cooling1,011 kWh/yr5.5$334
Kogan KASHSAC26UC2.9 kW heating2.6 kW cooling1,011 kWh/yr5.5$334
Kogan KASHSAC26UB2.9 kW heating2.6 kW cooling1,011 kWh/yr5.5$334
Braemar TCHV02T1S/TSHV02T1S3.3 kW heating2.6 kW cooling1,118 kWh/yr4.5$369

Compare TAC-10CHSD/VFIH with another model

TCL TAC-10CHSD specifications

Type
Reverse cycle
Configuration
Split system
Air distribution
Non-ducted
Indoor unit
Wall hung
Rated cooling capacity (35 Β°C)
2.64 kW
Cooling power input
0.55 kW
Rated heating capacity (7 Β°C)
3.30 kW
Heating power input
0.74 kW
EER, full load (tested)
4.80
COP, full load (tested)
4.72
Rated AEER
4.68
Rated ACOP
4.35
Standby power (PIA)
4.0 W
Compressor
Variable speed, Inverter
Refrigerant
R32
Power supply
Single phase
Indoor sound power
53.9 dB(A)
Outdoor sound power
62.8 dB(A)
Demand response (AS/NZS 4755)
Yes
Country of manufacture
China

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

TCL TAC-10CHSD zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––176330
Coldresidential4.52.51131,005
Mixedcommercial––252178
Mixedresidential4.53.0175392
Hotcommercial––58742
Hotresidential5.53.548464
Part-load test points (18 values)
h__h2_ext_cap_power_rated
1159 W
c__t1_half_cap_power_rated
225 W
c__t1_have_min_cap_results
No
h__h1_half_cap_power_rated
316 W
h__h1_have_min_cap_results
No
h__h3_have_ext_cap_results
No
h__h2_have_full_cap_results
No
h__h2_have_half_cap_results
No
h__h3_have_full_cap_results
No
h__h3_have_half_cap_results
No
h__h2_ext_cap_heat_cap_rated
3650 W
h__h1_half_cap_heat_cap_rated
1767 W
h__h2_is_capable_extended_load
Yes
c__low_temp_half_cap_power_rated
161 W
c__low_temp_have_min_cap_results
No
c__t1_half_cap_cooling_cap_rated
1300 W
c__low_temp_have_half_cap_results
Yes
c__low_temp_half_cap_cooling_cap_rated
1340 W

Other model numbers on registration AAC8789

Registered together and sharing the same test results. Usually variants of the same unit.

New Zealand E3 registration details

Registration number
AAC8789
GEMS registration id
168703
Status
approved, available (self-reported)
Registration expires
14 April 2030
Registered for sale in
Australia, Fiji, New Zealand
Family
TAC-10CHSD/V*IH
Regulatory standard
[SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
Test standard
AS/NZS 3823.1.1:2012
MEPS
2019
Product class
Class 8