c/kWh
Energy rating (cooling)
2
Heating: 1
Annual electricity use
1,838 kWh
217 cooling + 1,621 heating
Estimated running cost
$607 / year
$51 / month Β· $6,065 over 10 years
Capacity
3.1 kW cooling
3.2 kW heating

21% less electricity than the median of 15 comparable 3.5 kW reverse cycle window / wall registrations (2,316 kWh a year) in the cold zone. Uses less than 87% of them.

Across all 3,611 air conditioner registrations sold in Australia, it uses less than 78% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ— 33c/kWh in NZD; change the price above to your tariff.

TECO TVS32HVUVBH running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 1,838$607$6,065
Mixed zone 905$299$2,987
Hot zone 1,077$355$3,554

At 33c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Heat pumps that use less electricity

Same configuration and type, cooling capacity within 12% of 3.1 kW, at least 3% lower annual kWh in the cold zone.

ModelStarsEst. cost / yrCompare
Midea MWFF28H2.5 kW heating2.8 kW cooling1,546 kWh/yr2$510
Westinghouse WWH28HWC2.5 kW heating2.8 kW cooling1,546 kWh/yr2$510
Midea MWFF26H2.5 kW heating2.8 kW cooling1,546 kWh/yr2$510
Gree GJH09AK-K6NRNB9A2.5 kW heating2.8 kW cooling1,642 kWh/yr1.5$542
TECO TWW27HFWDG2.5 kW heating2.8 kW cooling1,642 kWh/yr1.5$542

Heat pumps similar to the TECO TVS32HVUVBH

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
Kogan KASVWAC30Y*3.2 kW heating3.1 kW cooling1,767 kWh/yr2$583
Kogan KASVWAC30YC3.2 kW heating3.1 kW cooling1,767 kWh/yr2$583
Midea MWFF26H2.5 kW heating2.8 kW cooling1,546 kWh/yr2$510
Westinghouse WWH27CWA2.5 kW heating2.8 kW cooling1,642 kWh/yr1.5$542
Midea MWFF28H2.5 kW heating2.8 kW cooling1,546 kWh/yr2$510
Gree GJH09AK-K6NRNR1A2.5 kW heating2.8 kW cooling1,642 kWh/yr1.5$542
Westinghouse WWH28HWC2.5 kW heating2.8 kW cooling1,546 kWh/yr2$510
Kelvinator KWH27HRF2.5 kW heating2.8 kW cooling1,642 kWh/yr1.5$542

Compare TVS32HVUVBH with another model

TECO TVS32HVUVBH specifications

Type
Reverse cycle
Configuration
Window / wall
Air distribution
Non-ducted
Indoor unit
–
Rated cooling capacity (35 Β°C)
3.08 kW
Cooling power input
1.00 kW
Rated heating capacity (7 Β°C)
3.22 kW
Heating power input
0.95 kW
EER, full load (tested)
3.09
COP, full load (tested)
3.34
Rated AEER
3.07
Rated ACOP
3.38
Standby power (PIA)
1.0 W
Compressor
Variable speed, Inverter
Refrigerant
R32
Power supply
Single phase
Indoor sound power
59 dB(A)
Outdoor sound power
65 dB(A)
Demand response (AS/NZS 4755)
No
Country of manufacture
China

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

TECO TVS32HVUVBH zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––464481
Coldresidential2.01.02171,621
Mixedcommercial––583224
Mixedresidential2.01.5335570
Hotcommercial––1,36242
Hotresidential2.02.51,01067
Part-load test points (24 values)
h__h1_min_cap_power_rated
250 W
h__h2_ext_cap_power_rated
980 W
c__t1_half_cap_power_rated
460 W
c__t1_have_min_cap_results
No
h__h1_half_cap_power_rated
430 W
h__h1_have_min_cap_results
Yes
h__h3_have_ext_cap_results
No
h__h2_have_full_cap_results
No
h__h2_have_half_cap_results
No
h__h3_have_full_cap_results
No
h__h3_have_half_cap_results
No
h__h1_min_cap_heat_cap_rated
1150 W
h__h2_ext_cap_heat_cap_rated
2200 W
h__h1_half_cap_heat_cap_rated
1680 W
h__h2_is_capable_extended_load
Yes
c__low_temp_min_cap_power_rated
210 W
c__low_temp_full_cap_power_rated
914 W
c__low_temp_half_cap_power_rated
420.44 W
c__low_temp_have_min_cap_results
Yes
c__t1_half_cap_cooling_cap_rated
1630 W
c__low_temp_have_half_cap_results
No
c__low_temp_min_cap_cooling_cap_rated
1070 W
c__low_temp_full_cap_cooling_cap_rated
3317.16 W
c__low_temp_half_cap_cooling_cap_rated
1755.51 W

Other model numbers on registration AAC8563

Registered together and sharing the same test results. Usually variants of the same unit.

New Zealand E3 registration details

Registration number
AAC8563
GEMS registration id
165732
Status
approved, available (self-reported)
Registration expires
18 December 2029
Registered for sale in
Australia, Fiji, New Zealand
Family
TVS32HV***WBH
Regulatory standard
[SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
Test standard
AS/NZS 3823.1.1:2012
MEPS
2019
Product class
Class 5

Source: E3 programme registration data (EECA, New Zealand) (trans-Tasman E3 registration data published by DCCEEW on data.gov.au, CC BY 3.0 AU). Dataset published 25 September 2026; last checked 26 September 2026. Manufacturer: teco.com.au. How the derived figures are calculated.