c/kWh
Energy rating (cooling)
3.5
Heating: 2
Annual electricity use
2,030 kWh
285 cooling + 1,745 heating
Estimated running cost
$670 / year
$56 / month Β· $6,699 over 10 years
Capacity
5.3 kW cooling
5.2 kW heating

6% less electricity than the median of 236 comparable 5 kW reverse cycle split system registrations (2,154 kWh a year) in the cold zone. Uses less than 79% of them.

Across all 3,611 air conditioner registrations sold in Australia, it uses less than 76% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ— 33c/kWh in NZD; change the price above to your tariff.

TECO TWS-TSO52H3DVKT running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 2,030$670$6,699
Mixed zone 1,106$365$3,650
Hot zone 1,399$462$4,617

At 33c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Heat pumps that use less electricity

Same configuration and type, cooling capacity within 12% of 5.3 kW, at least 3% lower annual kWh in the cold zone.

ModelStarsEst. cost / yrCompare
Midea MFCA50VA-W/MFCA50VA-N5.2 kW heating5.2 kW cooling1,841 kWh/yr4.5$608
Daikin RXM50AVMA / FTXM50AVMA6 kW heating5 kW cooling1,881 kWh/yr5.5$621
Daikin RXM50WVMA / FTXM50WVMA6 kW heating5 kW cooling1,903 kWh/yr5$628
Solar Acdc DGWA1-ACDC-18KR25 kW heating5 kW cooling1,905 kWh/yr3.5$629
Hyundai HYSSSAC53TA5.3 kW heating5.3 kW cooling1,935 kWh/yr4$639

Heat pumps similar to the TECO TWS-TSO52H3DVKT

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
Kogan KASHSAC52TB5.2 kW heating5.3 kW cooling2,030 kWh/yr3.5$670
Kogan KASHSAC52T*5.2 kW heating5.3 kW cooling2,030 kWh/yr3.5$670
Midea MFCA50VA-W/MFCA50VA-N5.2 kW heating5.2 kW cooling1,841 kWh/yr4.5$608
Braemar TCHV05T1S/TSHV05T1S5.3 kW heating5.3 kW cooling1,935 kWh/yr4$639
Hyundai HYSSSAC53TA5.3 kW heating5.3 kW cooling1,935 kWh/yr4$639
Hyundai HYSSSAC53TC5.3 kW heating5.3 kW cooling1,935 kWh/yr4$639
TCL TAC-VX18HSV/UA5.3 kW heating5.3 kW cooling1,935 kWh/yr4$639
TCL TAC-VX18HSV/UB5.3 kW heating5.3 kW cooling1,935 kWh/yr4$639

Compare TWS-TSO52H3DVKT with another model

TECO TWS-TSO52H3DVKT specifications

Type
Reverse cycle
Configuration
Split system
Air distribution
Non-ducted
Indoor unit
Wall hung
Rated cooling capacity (35 Β°C)
5.25 kW
Cooling power input
1.52 kW
Rated heating capacity (7 Β°C)
5.20 kW
Heating power input
1.19 kW
EER, full load (tested)
3.55
COP, full load (tested)
4.33
Rated AEER
3.42
Rated ACOP
4.32
Standby power (PIA)
4.4 W
Compressor
Variable speed, Inverter
Refrigerant
R32
Power supply
Single phase
Indoor sound power
61 dB(A)
Outdoor sound power
64 dB(A)
Demand response (AS/NZS 4755)
Yes
Country of manufacture
China

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

TECO TWS-TSO52H3DVKT zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––465566
Coldresidential3.52.02851,745
Mixedcommercial––670298
Mixedresidential3.02.5451655
Hotcommercial––1,58867
Hotresidential3.53.01,296103
Part-load test points (18 values)
h__h2_ext_cap_power_rated
1390 W
c__t1_half_cap_power_rated
600 W
c__t1_have_min_cap_results
No
h__h1_half_cap_power_rated
506 W
h__h1_have_min_cap_results
No
h__h3_have_ext_cap_results
No
h__h2_have_full_cap_results
No
h__h2_have_half_cap_results
No
h__h3_have_full_cap_results
No
h__h3_have_half_cap_results
No
h__h2_ext_cap_heat_cap_rated
4600 W
h__h1_half_cap_heat_cap_rated
2600 W
h__h2_is_capable_extended_load
Yes
c__low_temp_half_cap_power_rated
432 W
c__low_temp_have_min_cap_results
No
c__t1_half_cap_cooling_cap_rated
2650 W
c__low_temp_have_half_cap_results
Yes
c__low_temp_half_cap_cooling_cap_rated
2680 W

New Zealand E3 registration details

Registration number
AAC8918
GEMS registration id
169325
Status
approved, available (self-reported)
Registration expires
27 May 2030
Registered for sale in
Australia, Fiji, New Zealand
Family
–
Regulatory standard
[SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
Test standard
AS/NZS 3823.1.1:2012
MEPS
2019
Product class
Class 9

Source: E3 programme registration data (EECA, New Zealand) (trans-Tasman E3 registration data published by DCCEEW on data.gov.au, CC BY 3.0 AU). Dataset published 25 September 2026; last checked 26 September 2026. Manufacturer: teco.com.au. How the derived figures are calculated.