Temperzone OPA186RKTY is a 18.2 kW reverse cycle ducted packaged heat pump registered for sale in New Zealand under the trans-Tasman E3 energy rating scheme (registration AAC6908).
- Energy rating (cooling)
- 1.5
- Heating: 1
- Annual electricity use
- 9,328 kWh
- 1,509 cooling + 7,819 heating
- Estimated running cost
- $3,078 / year
- $257 / month Β· $30,782 over 10 years
- Capacity
- 18.2 kW cooling
- 16.7 kW heating
4% less electricity than the median of 10 comparable 18 kW reverse cycle ducted packaged registrations (9,688 kWh a year) in the cold zone. Uses less than 60% of them.
Across all 3,611 air conditioner registrations sold in Australia, it uses less than 15% (this compares very different sizes, so the cohort figure above is the useful one).
Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ 33c/kWh in NZD; change the price above to your tariff.
Temperzone OPA186RKTY running cost by climate zone
| Climate zone | kWh / year | Per year | 10 years |
|---|---|---|---|
| Cold zone | 9,328 | $3,078 | $30,782 |
| Mixed zone | 5,378 | $1,775 | $17,747 |
| Hot zone | 7,295 | $2,407 | $24,074 |
At 33c/kWh. Formula: cost = annual kWh Γ price. The kWh figure is the labelβs residential estimate for that zone; commercial-profile figures are in the specifications.
Heat pumps that use less electricity
Same configuration and type, cooling capacity within 12% of 18.2 kW, at least 3% lower annual kWh in the cold zone.
| Model | Stars | Est. cost / yr | Compare |
|---|---|---|---|
| Temperzone OPA 171RLTFY17.3 kW heating16.4 kW cooling7,720 kWh/yr | 2.5 | $2,548 | |
| APAC P015AHR3SA-LTT14.2 kW heating16 kW cooling7,837 kWh/yr | 1.5 | $2,586 | |
| APAC P015AHR3SA-LTR14.2 kW heating16 kW cooling7,837 kWh/yr | 1.5 | $2,586 | |
| Temperzone OPA 171RLTFY17.3 kW heating16.4 kW cooling8,061 kWh/yr | 2.5 | $2,660 | |
| Actron Air PRV19BT-T19 kW heating19 kW cooling8,350 kWh/yr | 2.5 | $2,756 |
Heat pumps similar to the Temperzone OPA186RKTY
Technically comparable registrations: same configuration and type, capacity within 12%.
| Model | Stars | Est. cost / yr | Compare |
|---|---|---|---|
| AIRSTAGE RAQ/K/EC/WP/1718.7 kW heating18.1 kW cooling10,040 kWh/yr | 1.5 | $3,313 | |
| AIRSTAGE RAQ/K/EC/WP/*1718.7 kW heating18.1 kW cooling10,040 kWh/yr | 1.5 | $3,313 | |
| APAC P018AHR3TA-LI2061A17.8 kW heating17.8 kW cooling8,965 kWh/yr | 2 | $2,958 | |
| APAC P018AHR3TA-CI2061A17.8 kW heating17.8 kW cooling8,965 kWh/yr | 2 | $2,958 | |
| Daikin UAYN180AFY1A17.2 kW heating17.4 kW cooling10,894 kWh/yr | 1 | $3,595 | |
| Actron Air PRV19BT-T19 kW heating19 kW cooling8,350 kWh/yr | 2.5 | $2,756 | |
| Actron Air PKV210T-T20.1 kW heating19.1 kW cooling9,453 kWh/yr | 2 | $3,119 |
Other Temperzone models of similar capacity
| Model | Stars | Est. cost / yr | Compare |
|---|---|---|---|
| Temperzone OPA 186RKTYG17.5 kW heating17.8 kW cooling9,913 kWh/yr | 1.5 | $3,271 |
Compare OPA186RKTY with another model
Temperzone OPA186RKTY specifications
- Type
- Reverse cycle
- Configuration
- Packaged
- Air distribution
- Ducted
- Indoor unit
- β
- Rated cooling capacity (35 Β°C)
- 18.16 kW
- Cooling power input
- 5.50 kW
- Rated heating capacity (7 Β°C)
- 16.74 kW
- Heating power input
- 4.75 kW
- EER, full load (tested)
- 3.30
- COP, full load (tested)
- 3.52
- Rated AEER
- 3.29
- Rated ACOP
- 3.51
- Standby power (PIA)
- 4.5 W
- Compressor
- Fixed speed
- Refrigerant
- R410A
- Power supply
- Three phase
- Indoor sound power
- β
- Outdoor sound power
- β
- Demand response (AS/NZS 4755)
- Yes (requires additional part)
- Country of manufacture
- Australia, New Zealand
Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.
Temperzone OPA186RKTY zoned energy rating figures
As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.
| Zone | Profile | Cooling stars | Heating stars | Cooling kWh | Heating kWh |
|---|---|---|---|---|---|
| Coldcommercial | commercial | β | β | 3,512 | 2,619 |
| Coldresidential | residential | 1.5 | 1.0 | 1,509 | 7,819 |
| Mixedcommercial | commercial | β | β | 4,335 | 1,412 |
| Mixedresidential | residential | 1.5 | 1.0 | 2,289 | 3,089 |
| Hotcommercial | commercial | β | β | 9,390 | 301 |
| Hotresidential | residential | 1.5 | 1.0 | 6,813 | 482 |
Part-load test points (4 values)
- h__h2_full_cap_power_rated
- 4507 W
- h__h3_have_full_cap_results
- No
- h__h2_full_cap_heat_cap_rated
- 14061 W
- c__low_temp_have_full_cap_results
- No
Related Temperzone model numbers starting with OPA186RKTY
1 model numbers on 1 other registration. Variants registered separately can carry different star ratings and energy figures; check the registration number on the label.
| Model | Registration | Stars | kWh / yr | Registration expires |
|---|---|---|---|---|
| OPA 186RKTYG | AAC8136 | 1.5 | 9,913 | 24 March 2029 |
New Zealand E3 registration details
- Registration number
- AAC6908
- GEMS registration id
- 149369
- Status
- approved, available (self-reported)
- Registration expires
- 29 August 2027
- Registered for sale in
- Australia, Fiji, New Zealand
- Family
- β
- Regulatory standard
- [SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
- Test standard
- AS/NZS 3823.1.2:2012
- MEPS
- 2019
- Product class
- Class 6
Source: E3 programme registration data (EECA, New Zealand) (trans-Tasman E3 registration data published by DCCEEW on data.gov.au, CC BY 3.0 AU). Dataset published 19 September 2026; last checked 20 September 2026. How the derived figures are calculated.