New Zealand Β· costs in NZD

Reverse cycle packaged air conditioner
Temperzone OPA560RLTFPQ Heat Pump
Temperzone OPA560RLTFPQ is a 53.5 kW reverse cycle ducted packaged heat pump registered for sale in New Zealand under the trans-Tasman E3 energy rating scheme (registration AAC6437).
- Energy rating (cooling)
- 2
- Heating: 1
- Annual electricity use
- 32,956 kWh
- 3,918 cooling + 29,038 heating
- Estimated running cost
- $10,875 / year
- $906 / month Β· $108,755 over 10 years
- Capacity
- 53.5 kW cooling
- 57 kW heating
138% more electricity than the median of 24 comparable 50 kW reverse cycle ducted packaged registrations (13,853 kWh a year) in the cold zone. Uses less than 13% of them.
Across all 3,611 air conditioner registrations sold in Australia, it uses less than 3% (this compares very different sizes, so the cohort figure above is the useful one).
Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ 33c/kWh in NZD; change the price above to your tariff.
Temperzone OPA560RLTFPQ running cost by climate zone
| Climate zone | kWh / year | Per year | 10 years |
|---|---|---|---|
| Cold zone | 32,956 | $10,875 | $108,755 |
| Mixed zone | 17,223 | $5,684 | $56,836 |
| Hot zone | 19,831 | $6,544 | $65,442 |
At 33c/kWh. Formula: cost = annual kWh Γ price. The kWh figure is the labelβs residential estimate for that zone; commercial-profile figures are in the specifications.
Heat pumps that use less electricity
Same configuration and type, cooling capacity within 12% of 53.5 kW, at least 3% lower annual kWh in the cold zone.
| Model | Stars | Est. cost / yr | Compare |
|---|---|---|---|
| Caa HPA055R3AD53.3 kW heating53.4 kW cooling4,198 kWh/yr | 2 | $1,385 | |
| Actron Air PKY500T51.8 kW heating49.1 kW cooling4,474 kWh/yr | 1 | $1,476 | |
| APAC P055AHR3SA-LRR54 kW heating56.1 kW cooling4,561 kWh/yr | 1.5 | $1,505 | |
| APAC P055AHR3SA-RTT54 kW heating56.1 kW cooling4,561 kWh/yr | 1.5 | $1,505 | |
| Coates RPA-C05052.8 kW heating51.6 kW cooling4,725 kWh/yr | 1.5 | $1,559 |
Heat pumps similar to the Temperzone OPA560RLTFPQ
Technically comparable registrations: same configuration and type, capacity within 12%.
| Model | Stars | Est. cost / yr | Compare |
|---|---|---|---|
| Caa HPA055R3AD53.3 kW heating53.4 kW cooling4,198 kWh/yr | 2 | $1,385 | |
| Daikin UAYN530BFY1A54.3 kW heating53.4 kW cooling43,024 kWh/yr | 1 | $14,198 | |
| Daikin UAYN530AFY1A54.3 kW heating53.4 kW cooling43,024 kWh/yr | 1 | $14,198 | |
| Aggreko RPA-050D-R410A52.8 kW heating51.6 kW cooling4,725 kWh/yr | 1.5 | $1,559 | |
| Coates RPA-C05052.8 kW heating51.6 kW cooling4,725 kWh/yr | 1.5 | $1,559 | |
| AIRSTAGE RAQ/K/EC/WP/ECO/12050.2 kW heating51.2 kW cooling23,748 kWh/yr | 2 | $7,837 |
Other Temperzone models of similar capacity
| Model | Stars | Est. cost / yr | Compare |
|---|---|---|---|
| Temperzone OPA550RKTBG-P53.4 kW heating52.9 kW cooling5,006 kWh/yr | 1 | $1,652 | |
| Temperzone OPA 551RLTBP48.7 kW heating54.7 kW cooling29,555 kWh/yr | 1.5 | $9,753 |
Compare OPA560RLTFPQ with another model
Temperzone OPA560RLTFPQ specifications
- Type
- Reverse cycle
- Configuration
- Packaged
- Air distribution
- Ducted
- Indoor unit
- β
- Rated cooling capacity (35 Β°C)
- 53.55 kW
- Cooling power input
- 17.90 kW
- Rated heating capacity (7 Β°C)
- 56.96 kW
- Heating power input
- 19.10 kW
- EER, full load (tested)
- 2.99
- COP, full load (tested)
- 2.98
- Rated AEER
- 2.99
- Rated ACOP
- 2.98
- Standby power (PIA)
- 11.5 W
- Compressor
- Variable speed, Inverter
- Refrigerant
- R32
- Power supply
- Three phase
- Indoor sound power
- β
- Outdoor sound power
- β
- Demand response (AS/NZS 4755)
- Yes
- Country of manufacture
- New Zealand, Australia
Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.
Temperzone OPA560RLTFPQ zoned energy rating figures
As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.
| Zone | Profile | Cooling stars | Heating stars | Cooling kWh | Heating kWh |
|---|---|---|---|---|---|
| Coldcommercial | commercial | β | β | 7,476 | 9,477 |
| Coldresidential | residential | 2.0 | 1.0 | 3,918 | 29,038 |
| Mixedcommercial | commercial | β | β | 10,005 | 5,057 |
| Mixedresidential | residential | 2.0 | 1.0 | 6,066 | 11,157 |
| Hotcommercial | commercial | β | β | 23,858 | 1,040 |
| Hotresidential | residential | 2.0 | 1.0 | 18,183 | 1,648 |
Part-load test points (21 values)
- c__t1_min_cap_power_rated
- 6080 W
- c__t1_half_cap_power_rated
- 8220 W
- c__t1_have_min_cap_results
- Yes
- h__h1_half_cap_power_rated
- 8690 W
- h__h1_have_min_cap_results
- No
- h__h2_full_cap_power_rated
- 16774 W
- h__h2_have_half_cap_results
- No
- h__h3_have_full_cap_results
- No
- h__h3_have_half_cap_results
- No
- h__h1_half_cap_heat_cap_rated
- 27650 W
- h__h2_full_cap_heat_cap_rated
- 42873 W
- h__h2_is_capable_extended_load
- No
- c__low_temp_min_cap_power_rated
- 4590 W
- c__t1_min_cap_cooling_cap_rated
- 17350 W
- c__low_temp_full_cap_power_rated
- 16360.6 W
- c__low_temp_half_cap_power_rated
- 6880 W
- c__t1_half_cap_cooling_cap_rated
- 27740 W
- c__low_temp_have_half_cap_results
- Yes
- c__low_temp_min_cap_cooling_cap_rated
- 18170 W
- c__low_temp_full_cap_cooling_cap_rated
- 57673.35 W
- c__low_temp_half_cap_cooling_cap_rated
- 28040 W
New Zealand E3 registration details
- Registration number
- AAC6437
- GEMS registration id
- 137392
- Status
- approved, available (self-reported)
- Registration expires
- 13 February 2027
- Registered for sale in
- Australia, Fiji, New Zealand
- Family
- β
- Regulatory standard
- [SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
- Test standard
- AS/NZS 3823.1.2:2012
- MEPS
- 2019
- Product class
- Class 7
Source: E3 programme registration data (EECA, New Zealand) (trans-Tasman E3 registration data published by DCCEEW on data.gov.au, CC BY 3.0 AU). Dataset published 19 September 2026; last checked 20 September 2026. How the derived figures are calculated.