c/kWh
Energy rating (cooling)
1.5
Heating: 0
Annual electricity use
5,690 kWh
Estimated running cost
$1,878 / year
$156 / month Β· $18,777 over 10 years
Capacity
66 kW cooling
66.4 kW heating

84% less electricity than the median of 16 comparable 65 kW reverse cycle ducted packaged registrations (35,446 kWh a year) in the cold zone. Uses less than 81% of them.

Across all 3,611 air conditioner registrations sold in Australia, it uses less than 34% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ— 33c/kWh in NZD; change the price above to your tariff.

Temperzone OPA705RKTB running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 5,690$1,878$18,777
Mixed zone 8,618$2,844$28,439
Hot zone 25,559$8,434$84,345

At 33c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Heat pumps that use less electricity

Same configuration and type, cooling capacity within 12% of 66 kW, at least 3% lower annual kWh in the cold zone.

ModelStarsEst. cost / yrCompare
APAC P065AHR3SA-LTR62.9 kW heating63.5 kW cooling4,970 kWh/yr1.5$1,640
APAC P065AHR3SA-LBB62.9 kW heating63.5 kW cooling4,970 kWh/yr1.5$1,640

Heat pumps similar to the Temperzone OPA705RKTB

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
Daikin UAYN640AFY1A64.9 kW heating66.2 kW cooling39,023 kWh/yr1.5$12,878
Daikin UAYQ210CY1A64 kW heating63.7 kW cooling36,496 kWh/yr1.5$12,044
APAC P065AHR3SA-LRR62.9 kW heating63.5 kW cooling4,970 kWh/yr1.5$1,640
APAC P065AHR3SA-RTT62.9 kW heating63.5 kW cooling4,970 kWh/yr1.5$1,640
AIRSTAGE RAQ/K/WP/* 23071.6 kW heating68.8 kW cooling43,051 kWh/yr1$14,207
AIRSTAGE RAQ/K/WP/ECO/23071.6 kW heating68.8 kW cooling43,051 kWh/yr1$14,207

Other Temperzone models of similar capacity

ModelStarsEst. cost / yrCompare
Temperzone OPA 680RLTB2FPDQ64.5 kW heating65.1 kW cooling29,720 kWh/yr3$9,808
Temperzone OPA 680RLTB1FPQ63.5 kW heating65 kW cooling28,933 kWh/yr2$9,548

Compare OPA705RKTB with another model

Temperzone OPA705RKTB specifications

Type
Reverse cycle
Configuration
Packaged
Air distribution
Ducted
Indoor unit
–
Rated cooling capacity (35 Β°C)
66.00 kW
Cooling power input
20.60 kW
Rated heating capacity (7 Β°C)
66.40 kW
Heating power input
19.00 kW
EER, full load (tested)
3.00
COP, full load (tested)
3.63
Rated AEER
3.19
Rated ACOP
3.48
Standby power (PIA)
28.0 W
Compressor
Fixed speed
Refrigerant
R410A
Power supply
Three phase
Indoor sound power
–
Outdoor sound power
–
Demand response (AS/NZS 4755)
No
Country of manufacture
Australia, New Zealand

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

Temperzone OPA705RKTB zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––13,188–
Coldresidential1.50.05,690–
Mixedcommercial––16,270–
Mixedresidential1.50.08,618–
Hotcommercial––35,203–
Hotresidential1.50.025,559–
Part-load test points (1 values)
c__low_temp_have_full_cap_results
No

1 model numbers on 1 other registration. Variants registered separately can carry different star ratings and energy figures; check the registration number on the label.

ModelRegistrationStarskWh / yr
OPA705RKTBG-PAAC70791.55,690

New Zealand E3 registration details

Registration number
AAC7075
GEMS registration id
150350
Status
approved, available (self-reported)
Registration expires
5 October 2027
Registered for sale in
Australia, Fiji, New Zealand
Family
–
Regulatory standard
[SEER Non Multi-Split >65kW] GEMS (Air Conditioners above 65kW) Determination 2022
Test standard
AS/NZS 3823.1.2:2012
MEPS
2020
Product class
Class 24

Source: E3 programme registration data (EECA, New Zealand) (trans-Tasman E3 registration data published by DCCEEW on data.gov.au, CC BY 3.0 AU). Dataset published 19 September 2026; last checked 20 September 2026. How the derived figures are calculated.