c/kWh
Energy rating (cooling)
3
Heating: 1.5
Annual electricity use
6,888 kWh
810 cooling + 6,078 heating
Estimated running cost
$2,273 / year
$189 / month Β· $22,730 over 10 years
Capacity
14 kW cooling
16 kW heating

4% more electricity than the median of 66 comparable 14 kW reverse cycle split system registrations (6,658 kWh a year) in the cold zone. Uses less than 35% of them.

Across all 3,611 air conditioner registrations sold in Australia, it uses less than 25% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ— 33c/kWh in NZD; change the price above to your tariff.

Toshiba running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 6,888$2,273$22,730
Mixed zone 3,429$1,132$11,316
Hot zone 4,125$1,361$13,613

At 33c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Heat pumps that use less electricity

Same configuration and type, cooling capacity within 12% of 14 kW, at least 3% lower annual kWh in the cold zone.

ModelStarsEst. cost / yrCompare
Panasonic U-125PZ4R5 / S-1014PU3E12.5 kW heating12.5 kW cooling4,631 kWh/yr3$1,528
Panasonic U-125PZ4R8 / S-1014PU3E12.5 kW heating12.5 kW cooling4,631 kWh/yr3$1,528
Kaden KDI42 / KCI4213 kW heating12.5 kW cooling5,013 kWh/yr4$1,654
Mdv C-UV-125N8-QC3W / CSV-125N8-QC3W13 kW heating12.5 kW cooling5,013 kWh/yr4$1,654
Daikin RZAV125FV1 / FCTA125AVMA15 kW heating12.5 kW cooling5,020 kWh/yr4$1,657

Heat pumps similar to the Toshiba

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
Mitsubishi Heavy Industries FDC140VSX-W / FDE140VH16 kW heating14 kW cooling6,552 kWh/yr2.5$2,162
Mitsubishi Heavy Industries FDCA140VSX-W / FDE140VH16 kW heating14 kW cooling6,552 kWh/yr2.5$2,162
Mitsubishi Electric PUZ-ZM140VKA2-A/PCA-M140KA316 kW heating13.5 kW cooling6,597 kWh/yr2$2,177
Mitsubishi Electric PUZ-ZM140VKA2-A/PCA-M140KA216 kW heating13.5 kW cooling6,597 kWh/yr2$2,177
Mdv C-UV-140N8-QC3W / CSV-140N8-QC3W14.5 kW heating14 kW cooling5,771 kWh/yr4$1,904
Kaden KDI48 / KCI4814.5 kW heating14 kW cooling5,771 kWh/yr4$1,904
Panasonic U-140PZ4R5 / S-1014PU3E14 kW heating14 kW cooling5,410 kWh/yr3$1,785
Panasonic U-140PZ4R8 / S-1014PU3E14 kW heating14 kW cooling5,410 kWh/yr3$1,785

Compare RAV-GM1601ATP-A/RAV-GM1601CTP-A with another model

Toshiba specifications

Type
Reverse cycle
Configuration
Split system
Air distribution
Non-ducted
Indoor unit
Under ceiling
Rated cooling capacity (35 Β°C)
14.00 kW
Cooling power input
4.51 kW
Rated heating capacity (7 Β°C)
16.00 kW
Heating power input
4.38 kW
EER, full load (tested)
3.14
COP, full load (tested)
3.67
Rated AEER
3.09
Rated ACOP
3.63
Standby power (PIA)
7.3 W
Compressor
Variable speed, Inverter
Refrigerant
R32
Power supply
Single phase
Indoor sound power
–
Outdoor sound power
–
Demand response (AS/NZS 4755)
Yes
Country of manufacture
Thailand

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

Toshiba zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––1,7411,904
Coldresidential3.01.58106,078
Mixedcommercial––2,231910
Mixedresidential2.52.51,3042,125
Hotcommercial––5,083184
Hotresidential3.03.03,835290
Part-load test points (16 values)
h__h2_ext_cap_power_rated
3820 W
c__t1_half_cap_power_rated
1350 W
c__t1_have_min_cap_results
No
h__h1_half_cap_power_rated
1480 W
h__h1_have_min_cap_results
No
h__h3_have_ext_cap_results
No
h__h2_have_full_cap_results
No
h__h2_have_half_cap_results
No
h__h3_have_full_cap_results
No
h__h3_have_half_cap_results
No
h__h2_ext_cap_heat_cap_rated
11590 W
h__h1_half_cap_heat_cap_rated
8000 W
h__h2_is_capable_extended_load
Yes
c__low_temp_have_min_cap_results
No
c__t1_half_cap_cooling_cap_rated
7000 W
c__low_temp_have_half_cap_results
No

New Zealand E3 registration details

Registration number
AAC10002
GEMS registration id
177923
Status
approved, available (self-reported)
Registration expires
31 May 2031
Registered for sale in
Australia, Fiji, New Zealand
Family
–
Regulatory standard
[SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
Test standard
AS/NZS 3823.1.1:2012
MEPS
2019
Product class
Class 11

Source: E3 programme registration data (EECA, New Zealand) (trans-Tasman E3 registration data published by DCCEEW on data.gov.au, CC BY 3.0 AU). Dataset published 25 September 2026; last checked 26 September 2026. Manufacturer: toshiba-aircon.in.th. How the derived figures are calculated.