c/kWh
Energy rating (cooling)
4.5
Heating: 2.5
Annual electricity use
2,062 kWh
230 cooling + 1,832 heating
Estimated running cost
$680 / year
$57 / month Β· $6,805 over 10 years
Capacity
5.1 kW cooling
6.1 kW heating

4% less electricity than the median of 236 comparable 5 kW reverse cycle split system registrations (2,154 kWh a year) in the cold zone. Uses less than 72% of them.

Across all 3,612 air conditioner registrations sold in Australia, it uses less than 76% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ— 33c/kWh in NZD; change the price above to your tariff.

Westinghouse HSV187HWAE running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 2,062$680$6,805
Mixed zone 1,035$342$3,416
Hot zone 1,154$381$3,808

At 33c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Heat pumps that use less electricity

Same configuration and type, cooling capacity within 12% of 5.1 kW, at least 3% lower annual kWh in the cold zone.

ModelStarsEst. cost / yrCompare
Daikin RXM46AVMA / FTXM46AVMA4.7 kW heating4.6 kW cooling1,543 kWh/yr4.5$509
Daikin RXM46WVMA / FTXM46WVMA4.7 kW heating4.6 kW cooling1,571 kWh/yr4.5$518
Gree GWH15AGDXD-K6DNA1A/O / GWH15AGDXD-K6DNA1A/I4.7 kW heating4.6 kW cooling1,835 kWh/yr4$606
Gree GWH15QDXE-K6DNA1A/O / GWH15QDXE-K6DNC8B/I4.7 kW heating4.6 kW cooling1,839 kWh/yr3$607
Midea MFCA50VA-W/MFCA50VA-N5.2 kW heating5.2 kW cooling1,841 kWh/yr4.5$608

Heat pumps similar to the Westinghouse HSV187HWAE

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
Hisense HAW*18KR5.8 kW heating5.1 kW cooling2,162 kWh/yr5$713
Hisense HAWH18KR5.8 kW heating5.1 kW cooling2,162 kWh/yr5$713
Midea MFEP50VB-W/MFEP50VB-N6 kW heating5 kW cooling2,147 kWh/yr5.5$709
Actron Air WRC-050DS / WRE-050DS6 kW heating5 kW cooling2,147 kWh/yr5.5$709
Solar Acdc DGWA1-ACDC-18KR25 kW heating5 kW cooling1,905 kWh/yr3.5$629
Daikin RXM50AVMA / FTXM50AVMA6 kW heating5 kW cooling1,881 kWh/yr5.5$621
Daikin RXM50WVMA / FTXM50WVMA6 kW heating5 kW cooling1,903 kWh/yr5$628
Midea MFCA50VA-W/MFCA50VA-N5.2 kW heating5.2 kW cooling1,841 kWh/yr4.5$608

Compare HSV187HWAE/HSV187HWAI with another model

Westinghouse HSV187HWAE specifications

Type
Reverse cycle
Configuration
Split system
Air distribution
Non-ducted
Indoor unit
Wall hung
Rated cooling capacity (35 Β°C)
5.10 kW
Cooling power input
1.18 kW
Rated heating capacity (7 Β°C)
6.10 kW
Heating power input
1.30 kW
EER, full load (tested)
4.42
COP, full load (tested)
4.68
Rated AEER
4.31
Rated ACOP
4.68
Standby power (PIA)
1.2 W
Compressor
Variable speed, Inverter
Refrigerant
R32
Power supply
Single phase
Indoor sound power
63.7 dB(A)
Outdoor sound power
67.3 dB(A)
Demand response (AS/NZS 4755)
Yes
Country of manufacture
China

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

Westinghouse HSV187HWAE zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––393580
Coldresidential4.52.52301,832
Mixedcommercial––552299
Mixedresidential4.03.0362673
Hotcommercial––1,31461
Hotresidential4.54.01,05896
Part-load test points (23 values)
c__t1_min_cap_power_rated
431 W
h__h1_min_cap_power_rated
360 W
h__h2_ext_cap_power_rated
1800 W
c__t1_half_cap_power_rated
540 W
c__t1_have_min_cap_results
Yes
h__h1_half_cap_power_rated
535 W
h__h1_have_min_cap_results
Yes
h__h3_have_ext_cap_results
No
h__h2_have_full_cap_results
No
h__h2_have_half_cap_results
No
h__h3_have_full_cap_results
No
h__h3_have_half_cap_results
No
h__h1_min_cap_heat_cap_rated
2041 W
h__h2_ext_cap_heat_cap_rated
5800 W
h__h1_half_cap_heat_cap_rated
3085 W
h__h2_is_capable_extended_load
Yes
c__low_temp_min_cap_power_rated
325 W
c__t1_min_cap_cooling_cap_rated
1800 W
c__low_temp_half_cap_power_rated
405 W
c__t1_half_cap_cooling_cap_rated
2460 W
c__low_temp_have_half_cap_results
Yes
c__low_temp_min_cap_cooling_cap_rated
2200 W
c__low_temp_half_cap_cooling_cap_rated
2780 W

Other model numbers on registration AAC7553

Registered together and sharing the same test results. Usually variants of the same unit.

New Zealand E3 registration details

Registration number
AAC7553
GEMS registration id
154739
Status
approved, available (self-reported)
Registration expires
5 June 2028
Registered for sale in
Australia, New Zealand
Family
WSD51HWA-E/WSD51HWA-I
Regulatory standard
[SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
Test standard
AS/NZS 3823.1.1:2012
MEPS
2019
Product class
Class 9