c/kWh
Energy rating (cooling)
4
Heating: 2.5
Annual electricity use
3,063 kWh
352 cooling + 2,711 heating
Estimated running cost
$1,011 / year
$84 / month Β· $10,108 over 10 years
Capacity
7.3 kW cooling
8.3 kW heating

2% less electricity than the median of 203 comparable 7 kW reverse cycle split system registrations (3,143 kWh a year) in the cold zone. Uses less than 65% of them.

Across all 3,611 air conditioner registrations sold in Australia, it uses less than 61% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ— 33c/kWh in NZD; change the price above to your tariff.

Westinghouse WSD73HWB-I running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 3,063$1,011$10,108
Mixed zone 1,563$516$5,158
Hot zone 1,808$597$5,966

At 33c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Heat pumps that use less electricity

Same configuration and type, cooling capacity within 12% of 7.3 kW, at least 3% lower annual kWh in the cold zone.

ModelStarsEst. cost / yrCompare
Panasonic U-71PZ3R5/S-6071PT3E6.8 kW heating6.8 kW cooling2,584 kWh/yr3$853
Panasonic U-71PZ4R5 / S-6071PT3E6.8 kW heating6.8 kW cooling2,606 kWh/yr3$860
Solar Acdc DGWA5-ACDCBLW-24KR27 kW heating6.5 kW cooling2,612 kWh/yr5$862
Daikin RZAV71CV1 / FCTA71AVMA8 kW heating7.1 kW cooling2,676 kWh/yr0.5$883
Midea UCMI70OB/CASMI70IB7.7 kW heating7 kW cooling2,745 kWh/yr3$906

Heat pumps similar to the Westinghouse WSD73HWB-I

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
Spt AW073C-1 / AW073E8.1 kW heating7.3 kW cooling3,037 kWh/yr4$1,002
Braemar TCHV07T1S/TSHV07T1S7.3 kW heating7.2 kW cooling2,833 kWh/yr3.5$935
Bonaire STH072S1AE/STH072S1AI7.3 kW heating7.2 kW cooling2,833 kWh/yr3.5$935
Hyundai HYSSSAC72TD7.3 kW heating7.2 kW cooling2,833 kWh/yr3.5$935
TCL TAC-24CHSD/TPH21IH7.3 kW heating7.2 kW cooling2,833 kWh/yr3.5$935
Hyundai HYSSSAC72TB7.3 kW heating7.2 kW cooling2,833 kWh/yr3.5$935
TCL TAC-24CHSD/VEIH7.3 kW heating7.2 kW cooling2,833 kWh/yr3.5$935
Braemar TCHV70T1S/TSHV70T1S7.2 kW heating7.2 kW cooling2,905 kWh/yr3.5$959

Compare WSD73HWB-I/WSD73HWA-E with another model

Westinghouse WSD73HWB-I specifications

Type
Reverse cycle
Configuration
Split system
Air distribution
Non-ducted
Indoor unit
Wall hung
Rated cooling capacity (35 Β°C)
7.30 kW
Cooling power input
1.97 kW
Rated heating capacity (7 Β°C)
8.30 kW
Heating power input
2.06 kW
EER, full load (tested)
3.77
COP, full load (tested)
3.94
Rated AEER
3.70
Rated ACOP
4.03
Standby power (PIA)
1.2 W
Compressor
Variable speed, Inverter
Refrigerant
R32
Power supply
Single phase
Indoor sound power
58.1 dB(A)
Outdoor sound power
66.1 dB(A)
Demand response (AS/NZS 4755)
Yes
Country of manufacture
China

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

Westinghouse WSD73HWB-I zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––696837
Coldresidential4.02.53522,711
Mixedcommercial––923429
Mixedresidential3.53.0565998
Hotcommercial––2,16585
Hotresidential4.03.51,672136
Part-load test points (23 values)
c__t1_min_cap_power_rated
630 W
h__h1_min_cap_power_rated
423 W
h__h2_ext_cap_power_rated
3070 W
c__t1_half_cap_power_rated
675 W
c__t1_have_min_cap_results
Yes
h__h1_half_cap_power_rated
716 W
h__h1_have_min_cap_results
Yes
h__h3_have_ext_cap_results
No
h__h2_have_full_cap_results
No
h__h2_have_half_cap_results
No
h__h3_have_full_cap_results
No
h__h3_have_half_cap_results
No
h__h1_min_cap_heat_cap_rated
2300 W
h__h2_ext_cap_heat_cap_rated
8400 W
h__h1_half_cap_heat_cap_rated
3850 W
h__h2_is_capable_extended_load
Yes
c__low_temp_min_cap_power_rated
536 W
c__t1_min_cap_cooling_cap_rated
3312 W
c__low_temp_half_cap_power_rated
620 W
c__t1_half_cap_cooling_cap_rated
3500 W
c__low_temp_have_half_cap_results
Yes
c__low_temp_min_cap_cooling_cap_rated
3800 W
c__low_temp_half_cap_cooling_cap_rated
4190 W

Other model numbers on registration AAC7554

Registered together and sharing the same test results. Usually variants of the same unit.

New Zealand E3 registration details

Registration number
AAC7554
GEMS registration id
154749
Status
approved, available (self-reported)
Registration expires
5 June 2028
Registered for sale in
Australia, New Zealand
Family
WSD73HWA-E/WSD73HWA-I
Regulatory standard
[SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
Test standard
AS/NZS 3823.1.1:2012
MEPS
2019
Product class
Class 9

Source: E3 programme registration data (EECA, New Zealand) (trans-Tasman E3 registration data published by DCCEEW on data.gov.au, CC BY 3.0 AU). Dataset published 25 September 2026; last checked 26 September 2026. How the derived figures are calculated.