c/kWh
Energy rating (cooling)
4
Heating: 3
Annual electricity use
2,126 kWh
717 cooling + 1,409 heating
Estimated running cost
$680 / year
$57 / month Β· $6,803 over 10 years
Capacity
10.5 kW cooling
11.5 kW heating

12% less electricity than the median of 129 comparable 10 kW reverse cycle ducted split system registrations (2,429 kWh a year) in the mixed zone. Uses less than 88% of them.

Across all 3,680 air conditioner registrations sold in Australia, it uses less than 49% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the mixed zone (Richmond NSW climate: Sydney, Melbourne, Adelaide, Perth). Mixed climate zone shown by default (Sydney, Melbourne, Adelaide, Perth); switch to cold or hot. Cost = kWh Γ— 32c/kWh in AUD; change the price above to your tariff.

Actron Air LRC-100CS running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 4,311$1,380$13,795
Mixed zone 2,126$680$6,803
Hot zone 2,072$663$6,630

At 32c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Air conditioners that use less electricity

Same configuration and type, cooling capacity within 12% of 10.5 kW, at least 3% lower annual kWh in the mixed zone.

ModelStarsEst. cost / yrCompare
Panasonic U-100PZ4R8 / S-100PE4RN10 kW heating10 kW cooling1,449 kWh/yr2.5$464
Panasonic U-100PZ4R8 / S-100PE4R10 kW heating10 kW cooling1,449 kWh/yr2.5$464
Brivis AONSR13B1/AINHU11B111.3 kW heating10.3 kW cooling1,881 kWh/yr4.5$602

Air conditioners similar to the Actron Air LRC-100CS

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
Kaden KDI3611.5 kW heating10.5 kW cooling2,325 kWh/yr3$744
Midea UCMI90OB/DUCMI90IB11 kW heating10.5 kW cooling2,122 kWh/yr4$679
Kaden KDI36 / KDI3611.5 kW heating10.5 kW cooling2,174 kWh/yr4$696
Aurora AU-BS36HR-2A-O / AU-LCF36-2A-I11.5 kW heating10.5 kW cooling2,151 kWh/yr4$688
Mdv C-UV-105N8-QC3W / CDV-105HN8-QC3W11 kW heating10.5 kW cooling2,126 kWh/yr4$680
Rinnai DONSR11B1/DINLR11B111.5 kW heating10.5 kW cooling2,165 kWh/yr4$693
Mdv C-UV-105N8-QC3W / CDV-105A6N8-QC3W11 kW heating10.5 kW cooling2,135 kWh/yr4$683
Rinnai DONSR11B1/DINLR11B111.5 kW heating10.5 kW cooling2,164 kWh/yr4$692

Compare LRC-100CS / LRE-100CS with another model

Actron Air LRC-100CS specifications

Type
Reverse cycle
Configuration
Split system
Air distribution
Ducted
Indoor unit
–
Rated cooling capacity (35 Β°C)
10.50 kW
Cooling power input
3.09 kW
Rated heating capacity (7 Β°C)
11.50 kW
Heating power input
2.70 kW
EER, full load (tested)
3.31
COP, full load (tested)
4.18
Rated AEER
3.36
Rated ACOP
4.21
Standby power (PIA)
10.0 W
Compressor
Variable speed, Inverter
Refrigerant
R32
Power supply
Single phase
Indoor sound power
–
Outdoor sound power
–
Demand response (AS/NZS 4755)
Yes
Country of manufacture
China

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

Actron Air LRC-100CS zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––3561,199
Coldresidential4.52.04463,865
Mixedcommercial––933612
Mixedresidential4.03.07171,409
Hotcommercial––-134135
Hotresidential5.53.51,861211
Part-load test points (20 values)
c__t1_min_cap_power_rated
731 W
h__h1_min_cap_power_rated
481 W
h__h2_ext_cap_power_rated
3485 W
c__t1_half_cap_power_rated
1838 W
c__t1_have_min_cap_results
Yes
h__h1_half_cap_power_rated
1126 W
h__h1_have_min_cap_results
Yes
h__h1_min_cap_heat_cap_rated
2570 W
h__h2_ext_cap_heat_cap_rated
10230 W
h__h1_half_cap_heat_cap_rated
5830 W
h__h2_is_capable_extended_load
Yes
c__low_temp_min_cap_power_rated
354 W
c__t1_min_cap_cooling_cap_rated
3110 W
c__low_temp_full_cap_power_rated
2824.26 W
c__low_temp_half_cap_power_rated
819 W
c__t1_half_cap_cooling_cap_rated
5570 W
c__low_temp_have_half_cap_results
Yes
c__low_temp_min_cap_cooling_cap_rated
2660 W
c__low_temp_full_cap_cooling_cap_rated
11308.5 W
c__low_temp_half_cap_cooling_cap_rated
5380 W

Australian GEMS registration details

Registration number
AAC6916
GEMS registration id
146387
Status
approved, available (self-reported)
Registration expires
30 August 2027
Registered for sale in
Australia, New Zealand
Family
–
Regulatory standard
[SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
Test standard
AS/NZS 3823.1.2:2012
MEPS
2019
Product class
Class 11

Source: Australian Government Energy Rating (GEMS) registration data, DCCEEW via data.gov.au (CC BY 3.0 AU). Dataset published 25 September 2026; last checked 26 September 2026. Manufacturer: actronair.com.au. How the derived figures are calculated.