Australia Β· costs in AUD

Reverse cycle split system air conditioner
Rinnai DONSR11B1/DINLR11B1 Air Conditioner
Rinnai DONSR11B1/DINLR11B1 is a 10.5 kW reverse cycle ducted split system air conditioner registered under Australiaβs Energy Rating (GEMS) scheme (registration AAC6725).
A newer registration of this model exists: AAC8198.
- Energy rating (cooling)
- 4
- Heating: 2.5
- Annual electricity use
- 2,164 kWh
- 724 cooling + 1,440 heating
- Estimated running cost
- $692 / year
- $58 / month Β· $6,925 over 10 years
- Capacity
- 10.5 kW cooling
- 11.5 kW heating
11% less electricity than the median of 129 comparable 10 kW reverse cycle ducted split system registrations (2,429 kWh a year) in the mixed zone. Uses less than 85% of them.
Across all 3,680 air conditioner registrations sold in Australia, it uses less than 48% (this compares very different sizes, so the cohort figure above is the useful one).
Annual kWh is the government label figure for a residential user in the mixed zone (Richmond NSW climate: Sydney, Melbourne, Adelaide, Perth). Mixed climate zone shown by default (Sydney, Melbourne, Adelaide, Perth); switch to cold or hot. Cost = kWh Γ 32c/kWh in AUD; change the price above to your tariff.
Rinnai DONSR11B1 running cost by climate zone
| Climate zone | kWh / year | Per year | 10 years |
|---|---|---|---|
| Cold zone | 4,403 | $1,409 | $14,090 |
| Mixed zone | 2,164 | $692 | $6,925 |
| Hot zone | 2,031 | $650 | $6,499 |
At 32c/kWh. Formula: cost = annual kWh Γ price. The kWh figure is the labelβs residential estimate for that zone; commercial-profile figures are in the specifications.
Air conditioners that use less electricity
Same configuration and type, cooling capacity within 12% of 10.5 kW, at least 3% lower annual kWh in the mixed zone.
| Model | Stars | Est. cost / yr | Compare |
|---|---|---|---|
| Panasonic U-100PZ4R8 / S-100PE4RN10 kW heating10 kW cooling1,449 kWh/yr | 2.5 | $464 | |
| Panasonic U-100PZ4R8 / S-100PE4R10 kW heating10 kW cooling1,449 kWh/yr | 2.5 | $464 | |
| Brivis AONSR13B1/AINHU11B111.3 kW heating10.3 kW cooling1,881 kWh/yr | 4.5 | $602 |
Air conditioners similar to the Rinnai DONSR11B1
Technically comparable registrations: same configuration and type, capacity within 12%.
| Model | Stars | Est. cost / yr | Compare |
|---|---|---|---|
| Midea UCMI90OB/DUCMI90IB11 kW heating10.5 kW cooling2,122 kWh/yr | 4 | $679 | |
| Kaden KDI36 / KDI3611.5 kW heating10.5 kW cooling2,174 kWh/yr | 4 | $696 | |
| Aurora AU-BS36HR-2A-O / AU-LCF36-2A-I11.5 kW heating10.5 kW cooling2,151 kWh/yr | 4 | $688 | |
| Actron Air LRC-100CS / LRE-100CS11.5 kW heating10.5 kW cooling2,126 kWh/yr | 4 | $680 | |
| Mdv C-UV-105N8-QC3W / CDV-105HN8-QC3W11 kW heating10.5 kW cooling2,126 kWh/yr | 4 | $680 | |
| Carrier 38QSV105N8/42QSV105N8H12.5 kW heating10.5 kW cooling2,355 kWh/yr | 3.5 | $754 | |
| Mdv C-UV-105N8-QC3W / CDV-105A6N8-QC3W11 kW heating10.5 kW cooling2,135 kWh/yr | 4 | $683 | |
| Kaden KDI3611.5 kW heating10.5 kW cooling2,325 kWh/yr | 3 | $744 |
Compare DONSR11B1/DINLR11B1 with another model
Rinnai DONSR11B1 specifications
- Type
- Reverse cycle
- Configuration
- Split system
- Air distribution
- Ducted
- Indoor unit
- β
- Rated cooling capacity (35 Β°C)
- 10.50 kW
- Cooling power input
- 3.10 kW
- Rated heating capacity (7 Β°C)
- 11.50 kW
- Heating power input
- 2.70 kW
- EER, full load (tested)
- 3.33
- COP, full load (tested)
- 4.09
- Rated AEER
- 3.35
- Rated ACOP
- 4.21
- Standby power (PIA)
- 10.0 W
- Compressor
- Variable speed, Inverter
- Refrigerant
- R32
- Power supply
- Single phase
- Indoor sound power
- β
- Outdoor sound power
- β
- Demand response (AS/NZS 4755)
- Yes
- Country of manufacture
- China
Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.
Rinnai DONSR11B1 zoned energy rating figures
As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.
| Zone | Profile | Cooling stars | Heating stars | Cooling kWh | Heating kWh |
|---|---|---|---|---|---|
| Coldcommercial | commercial | β | β | -211 | 1,255 |
| Coldresidential | residential | 4.5 | 2.0 | 437 | 3,966 |
| Mixedcommercial | commercial | β | β | 516 | 647 |
| Mixedresidential | residential | 4.0 | 2.5 | 724 | 1,440 |
| Hotcommercial | commercial | β | β | 632 | 143 |
| Hotresidential | residential | 5.5 | 3.0 | 1,811 | 220 |
Part-load test points (25 values)
- c__t1_min_cap_power_rated
- 615 W
- h__h1_min_cap_power_rated
- 490 W
- h__h2_ext_cap_power_rated
- 3590 W
- c__t1_half_cap_power_rated
- 1650 W
- c__t1_have_min_cap_results
- Yes
- h__h1_half_cap_power_rated
- 1080 W
- h__h1_have_min_cap_results
- Yes
- h__h3_have_ext_cap_results
- No
- h__h2_have_full_cap_results
- No
- h__h2_have_half_cap_results
- No
- h__h3_have_full_cap_results
- No
- h__h3_have_half_cap_results
- No
- h__h1_min_cap_heat_cap_rated
- 2320 W
- h__h2_ext_cap_heat_cap_rated
- 10080 W
- h__h1_half_cap_heat_cap_rated
- 5690 W
- h__h2_is_capable_extended_load
- Yes
- c__low_temp_min_cap_power_rated
- 350 W
- c__t1_min_cap_cooling_cap_rated
- 2590 W
- c__low_temp_full_cap_power_rated
- 2833.4 W
- c__low_temp_half_cap_power_rated
- 710 W
- c__t1_half_cap_cooling_cap_rated
- 5145 W
- c__low_temp_have_half_cap_results
- Yes
- c__low_temp_min_cap_cooling_cap_rated
- 2630 W
- c__low_temp_full_cap_cooling_cap_rated
- 11308.5 W
- c__low_temp_half_cap_cooling_cap_rated
- 5070 W
Related Rinnai model numbers starting with DONSR11B1DINLR11B1
2 model numbers on 2 other registrations. Variants registered separately can carry different star ratings and energy figures; check the registration number on the label.
| Model | Registration | Stars | kWh / yr | Registration expires |
|---|---|---|---|---|
| DONSR11B1/DINLR11B1 | AAC8130 | 4 | 2,165 | 21 March 2029 |
| DONSR11B1/DINLR11B1 | AAC8198 | 3 | 2,305 | 1 May 2029 |
Australian GEMS registration details
- Registration number
- AAC6725
- GEMS registration id
- 147221
- Status
- approved, available (self-reported)
- Registration expires
- 24 May 2027
- Registered for sale in
- Australia, Fiji, New Zealand
- Family
- β
- Regulatory standard
- [SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
- Test standard
- AS/NZS 3823.1.2:2012
- MEPS
- 2019
- Product class
- Class 11
Source: Australian Government Energy Rating (GEMS) registration data, DCCEEW via data.gov.au (CC BY 3.0 AU). Dataset published 25 September 2026; last checked 26 September 2026. Manufacturer: rinnai.com.au. How the derived figures are calculated.