c/kWh
Energy rating (cooling)
4.5
Heating: 3
Annual electricity use
567 kWh
175 cooling + 392 heating
Estimated running cost
$181 / year
$15 / month Β· $1,814 over 10 years
Capacity
2.6 kW cooling
3.3 kW heating

4% more electricity than the median of 190 comparable 2.5 kW reverse cycle split system registrations (543 kWh a year) in the mixed zone. Uses less than 27% of them.

Across all 3,638 air conditioner registrations sold in Australia, it uses less than 91% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the mixed zone (Richmond NSW climate: Sydney, Melbourne, Adelaide, Perth). Mixed climate zone shown by default (Sydney, Melbourne, Adelaide, Perth); switch to cold or hot. Cost = kWh Γ— 32c/kWh in AUD; change the price above to your tariff.

Braemar TCHV02T1S running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 1,118$358$3,578
Mixed zone 567$181$1,814
Hot zone 548$175$1,754

At 32c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Air conditioners that use less electricity

Same configuration and type, cooling capacity within 12% of 2.6 kW, at least 3% lower annual kWh in the mixed zone.

ModelStarsEst. cost / yrCompare
Fujitsu AOTH09KNCA / ASTH09KNCA3.2 kW heating2.5 kW cooling0 kWh/yr–$0
Actron Air WRC-026DS / WRE-026DS2.7 kW heating2.6 kW cooling404 kWh/yr6.5$129
Midea MFEP26VB-W/MFEP26VB-N2.7 kW heating2.6 kW cooling404 kWh/yr6.5$129
Midea MFEP26VA-W/MFEP26VA-N2.7 kW heating2.6 kW cooling405 kWh/yr6.5$130
Actron Air WRC-026CS / WRE-026CS2.8 kW heating2.6 kW cooling410 kWh/yr6.5$131

Air conditioners similar to the Braemar TCHV02T1S

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
Akai AK-TP26M2.9 kW heating2.6 kW cooling497 kWh/yr5$159
Rinnai HONRT25B / HINRT25B2.9 kW heating2.6 kW cooling465 kWh/yr7$149
TECO TWS-TSO26H3DVHA2.9 kW heating2.6 kW cooling497 kWh/yr5$159
Rinnai HONRJ25B / HINRJ25B2.9 kW heating2.6 kW cooling465 kWh/yr7$149
Hyundai HYSSSAC26TC3.3 kW heating2.6 kW cooling552 kWh/yr5$177
Kogan KASHSAC26UA2.9 kW heating2.6 kW cooling497 kWh/yr5$159
Aux ASW-H27A4/FAR3DI2.9 kW heating2.6 kW cooling497 kWh/yr5$159
Kogan KASHSAC26UB2.9 kW heating2.6 kW cooling497 kWh/yr5$159

Compare TCHV02T1S/TSHV02T1S with another model

Braemar TCHV02T1S specifications

Type
Reverse cycle
Configuration
Split system
Air distribution
Non-ducted
Indoor unit
–
Rated cooling capacity (35 Β°C)
2.64 kW
Cooling power input
–
Rated heating capacity (7 Β°C)
3.30 kW
Heating power input
–
EER, full load (tested)
4.80
COP, full load (tested)
4.72
Rated AEER
4.69
Rated ACOP
4.35
Standby power (PIA)
4.0 W
Compressor
Variable speed, Inverter
Refrigerant
R32
Power supply
Single phase
Indoor sound power
53.9 dB(A)
Outdoor sound power
62.8 dB(A)
Demand response (AS/NZS 4755)
Yes
Country of manufacture
China

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

Braemar TCHV02T1S zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––176330
Coldresidential4.52.51131,005
Mixedcommercial––252178
Mixedresidential4.53.0175392
Hotcommercial––58742
Hotresidential5.53.548464
Part-load test points (18 values)
h__h2_ext_cap_power_rated
1159 W
c__t1_half_cap_power_rated
225 W
c__t1_have_min_cap_results
No
h__h1_half_cap_power_rated
316 W
h__h1_have_min_cap_results
No
h__h3_have_ext_cap_results
No
h__h2_have_full_cap_results
No
h__h2_have_half_cap_results
No
h__h3_have_full_cap_results
No
h__h3_have_half_cap_results
No
h__h2_ext_cap_heat_cap_rated
3650 W
h__h1_half_cap_heat_cap_rated
1767 W
h__h2_is_capable_extended_load
Yes
c__low_temp_half_cap_power_rated
161 W
c__low_temp_have_min_cap_results
No
c__t1_half_cap_cooling_cap_rated
1300 W
c__low_temp_have_half_cap_results
Yes
c__low_temp_half_cap_cooling_cap_rated
1340 W

Australian GEMS registration details

Registration number
AAC8849
GEMS registration id
–
Status
approved
Registration expires
14 May 2030
Registered for sale in
Australia, New Zealand
Family
–
Regulatory standard
Greenhouse and Energy Minimum Standards (Air Conditioners up to 65kW) Determination 2019
Test standard
AS/NZS 3823.1.1:2012
MEPS
2019
Product class
8

Source: Australian Government Energy Rating (GEMS) registration data, DCCEEW via data.gov.au (CC BY 3.0 AU). Dataset published 28 October 2026; last checked 29 October 2026. How the derived figures are calculated.