c/kWh
Energy rating (cooling)
3.5
Heating: 2.5
Annual electricity use
1,340 kWh
485 cooling + 855 heating
Estimated running cost
$429 / year
$36 / month Β· $4,288 over 10 years
Capacity
6.1 kW cooling
6.5 kW heating

About the same electricity as the median of 104 comparable 6 kW reverse cycle split system registrations (1,340 kWh a year) in the mixed zone. Uses less than 46% of them.

Across all 3,680 air conditioner registrations sold in Australia, it uses less than 67% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the mixed zone (Richmond NSW climate: Sydney, Melbourne, Adelaide, Perth). Mixed climate zone shown by default (Sydney, Melbourne, Adelaide, Perth); switch to cold or hot. Cost = kWh Γ— 32c/kWh in AUD; change the price above to your tariff.

Carrier Carrier Ambi running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 2,794$894$8,941
Mixed zone 1,340$429$4,288
Hot zone 1,546$495$4,947

At 32c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Air conditioners that use less electricity

Same configuration and type, cooling capacity within 12% of 6.1 kW, at least 3% lower annual kWh in the mixed zone.

ModelStarsEst. cost / yrCompare
Panasonic U-60PZ4R5 / S-6071PU3E6 kW heating6 kW cooling1,092 kWh/yr3.5$349
Panasonic U-60PZ3R5 / S-6071PU3E6 kW heating6 kW cooling1,101 kWh/yr3.5$352
Midea MFEZ60VA-W/MFEZ60VA-N6.5 kW heating6 kW cooling1,177 kWh/yr4.5$377
Rinnai HONRPX60/HINRPX60M6.5 kW heating6 kW cooling1,177 kWh/yr4.5$377
Actron Air WRC-060DS / WRE-060DS6.6 kW heating6 kW cooling1,203 kWh/yr4.5$385

Air conditioners similar to the Carrier Carrier Ambi

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
Midea MFEF60VA-W/MFEF60VA-N6.5 kW heating6.1 kW cooling1,340 kWh/yr3.5$429
Comfee CASG-XG60/CASN-XG606.4 kW heating6.1 kW cooling1,264 kWh/yr4$404
Mitsubishi Electric MUZ-LN60VGHZ/MSZ-LN60VGDV6.8 kW heating6.1 kW cooling1,418 kWh/yr3$454
LG WH21SLU-23 / WH21SLN-237 kW heating6.1 kW cooling1,316 kWh/yr4.5$421
Midea MFXP60W/MFXP60N6.6 kW heating6.1 kW cooling1,282 kWh/yr4$410
Mitsubishi Heavy Industries SRC60ZSXA-W/SRK60ZSXA-WF6.8 kW heating6.1 kW cooling1,337 kWh/yr3$428
Mitsubishi Electric MUZ-LN60VG2/MSZ-LN60VGDV6.8 kW heating6.1 kW cooling1,418 kWh/yr3$454
Mitsubishi Heavy Industries SRC60ZSXA-W / SRK60ZSXA-W6.8 kW heating6.1 kW cooling1,334 kWh/yr3$427

Compare Carrier Ambi with another model

Carrier Carrier Ambi specifications

Type
Reverse cycle
Configuration
Split system
Air distribution
Non-ducted
Indoor unit
Wall hung
Rated cooling capacity (35 Β°C)
6.10 kW
Cooling power input
1.78 kW
Rated heating capacity (7 Β°C)
6.55 kW
Heating power input
1.69 kW
EER, full load (tested)
3.40
COP, full load (tested)
3.85
Rated AEER
3.42
Rated ACOP
3.87
Standby power (PIA)
0.6 W
Compressor
Variable speed, Inverter
Refrigerant
R32
Power supply
Single phase
Indoor sound power
62.7 dB(A)
Outdoor sound power
67.4 dB(A)
Demand response (AS/NZS 4755)
Yes
Country of manufacture
China

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

Carrier Carrier Ambi zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––483765
Coldresidential4.01.53032,491
Mixedcommercial––702375
Mixedresidential3.52.5485855
Hotcommercial––1,75168
Hotresidential4.03.51,437109
Part-load test points (23 values)
c__t1_min_cap_power_rated
480 W
h__h1_min_cap_power_rated
445 W
h__h2_ext_cap_power_rated
1630 W
c__t1_half_cap_power_rated
710 W
c__t1_have_min_cap_results
Yes
h__h1_half_cap_power_rated
618 W
h__h1_have_min_cap_results
Yes
h__h3_have_ext_cap_results
No
h__h2_have_full_cap_results
No
h__h2_have_half_cap_results
No
h__h3_have_full_cap_results
No
h__h3_have_half_cap_results
No
h__h1_min_cap_heat_cap_rated
2400 W
h__h2_ext_cap_heat_cap_rated
4700 W
h__h1_half_cap_heat_cap_rated
3280 W
h__h2_is_capable_extended_load
Yes
c__low_temp_min_cap_power_rated
355 W
c__t1_min_cap_cooling_cap_rated
1900 W
c__low_temp_half_cap_power_rated
510 W
c__t1_half_cap_cooling_cap_rated
3050 W
c__low_temp_have_half_cap_results
Yes
c__low_temp_min_cap_cooling_cap_rated
2430 W
c__low_temp_half_cap_cooling_cap_rated
3200 W

4 model numbers on 4 other registrations. Variants registered separately can carry different star ratings and energy figures; check the registration number on the label.

ModelRegistrationStarskWh / yr
Carrier AmbiZAC08363.51,538
Carrier AmbiZAC08373.51,794
Carrier AmbiZAC08385391
Carrier AmbiZAC083941,067

Australian GEMS registration details

Registration number
ZAC0834
GEMS registration id
175737
Status
approved, unavailable (self-reported)
Registration expires
n/a (NZ registration)
Registered for sale in
Australia, Fiji, New Zealand
Family
Carrier Ambi
Regulatory standard
[SEER Non Multi-Split <=65kW] (Air Conditioners up to 65kW) EE Regulations 2020 Schedule 2A
Test standard
AS/NZS 3823.1.1:2012
MEPS
2019
Product class
Class 9

Source: Australian Government Energy Rating (GEMS) registration data, DCCEEW via data.gov.au (CC BY 3.0 AU). Dataset published 25 September 2026; last checked 26 September 2026. Manufacturer: ahi-carrier.co.nz. How the derived figures are calculated.