c/kWh
Energy rating (cooling)
5
Heating: 3.5
Annual electricity use
391 kWh
129 cooling + 262 heating
Estimated running cost
$125 / year
$10 / month Β· $1,251 over 10 years
Capacity
2.1 kW cooling
2.5 kW heating

7% less electricity than the median of 62 comparable 2 kW reverse cycle split system registrations (422 kWh a year) in the mixed zone. Uses less than 73% of them.

Across all 3,680 air conditioner registrations sold in Australia, it uses less than 97% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the mixed zone (Richmond NSW climate: Sydney, Melbourne, Adelaide, Perth). Mixed climate zone shown by default (Sydney, Melbourne, Adelaide, Perth); switch to cold or hot. Cost = kWh Γ— 32c/kWh in AUD; change the price above to your tariff.

Carrier Carrier Ambi running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 750$240$2,400
Mixed zone 391$125$1,251
Hot zone 415$133$1,328

At 32c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Air conditioners that use less electricity

Same configuration and type, cooling capacity within 12% of 2.1 kW, at least 3% lower annual kWh in the mixed zone.

ModelStarsEst. cost / yrCompare
Comfee CASG-XG20/CASN-XG202.2 kW heating2 kW cooling367 kWh/yr5$117
Midea MFXP20W/MFXP20N2.3 kW heating2 kW cooling370 kWh/yr5$118
Kaden KSI062.3 kW heating2 kW cooling370 kWh/yr5$118
Midea MFAB-20WC/MFAB-20NC2.3 kW heating2 kW cooling370 kWh/yr5$118
Carrier 38QHG020N8/42QHG020N8-12.2 kW heating2 kW cooling378 kWh/yr5$121

Air conditioners similar to the Carrier Carrier Ambi

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
TCL TAC-08CHSD/TPH11ITU2.1 kW heating2.1 kW cooling428 kWh/yr3.5$137
Hyundai HYSSSAC21TB2.1 kW heating2.1 kW cooling428 kWh/yr3.5$137
Midea MFEZ20VA-W/MFEZ20VA-N2.5 kW heating2.1 kW cooling391 kWh/yr5$125
Maxa LZL21 ODU / LZL21 IDU2.1 kW heating2.1 kW cooling597 kWh/yr3.5$191
Midea MFEF20VA-W/MFEF20VA-N2.5 kW heating2.1 kW cooling391 kWh/yr5$125
Hyundai HYSSSAC21TD2.1 kW heating2.1 kW cooling428 kWh/yr3.5$137
TCL TAC-08CHSD/TPH21ITU2.1 kW heating2.1 kW cooling428 kWh/yr3.5$137
Daikin RXM20AVMA / FTXM20AVMA2.7 kW heating2.2 kW cooling380 kWh/yr5.5$122

Compare Carrier Ambi with another model

Carrier Carrier Ambi specifications

Type
Reverse cycle
Configuration
Split system
Air distribution
Non-ducted
Indoor unit
Wall hung
Rated cooling capacity (35 Β°C)
2.15 kW
Cooling power input
0.44 kW
Rated heating capacity (7 Β°C)
2.45 kW
Heating power input
0.46 kW
EER, full load (tested)
4.91
COP, full load (tested)
5.30
Rated AEER
4.83
Rated ACOP
5.37
Standby power (PIA)
0.4 W
Compressor
Variable speed, Inverter
Refrigerant
R32
Power supply
Single phase
Indoor sound power
55.1 dB(A)
Outdoor sound power
58.5 dB(A)
Demand response (AS/NZS 4755)
Yes
Country of manufacture
China

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

Carrier Carrier Ambi zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––132223
Coldresidential5.53.081669
Mixedcommercial––190121
Mixedresidential5.03.5129262
Hotcommercial––45625
Hotresidential6.03.537540
Part-load test points (23 values)
c__t1_min_cap_power_rated
144.8 W
h__h1_min_cap_power_rated
164 W
h__h2_ext_cap_power_rated
780 W
c__t1_half_cap_power_rated
200 W
c__t1_have_min_cap_results
Yes
h__h1_half_cap_power_rated
218 W
h__h1_have_min_cap_results
Yes
h__h3_have_ext_cap_results
No
h__h2_have_full_cap_results
No
h__h2_have_half_cap_results
No
h__h3_have_full_cap_results
No
h__h3_have_half_cap_results
No
h__h1_min_cap_heat_cap_rated
895 W
h__h2_ext_cap_heat_cap_rated
2780 W
h__h1_half_cap_heat_cap_rated
1230 W
h__h2_is_capable_extended_load
Yes
c__low_temp_min_cap_power_rated
107 W
c__t1_min_cap_cooling_cap_rated
710 W
c__low_temp_half_cap_power_rated
142 W
c__t1_half_cap_cooling_cap_rated
1050 W
c__low_temp_have_half_cap_results
Yes
c__low_temp_min_cap_cooling_cap_rated
878 W
c__low_temp_half_cap_cooling_cap_rated
1186 W

4 model numbers on 4 other registrations. Variants registered separately can carry different star ratings and energy figures; check the registration number on the label.

ModelRegistrationStarskWh / yr
Carrier AmbiZAC08343.51,340
Carrier AmbiZAC08363.51,538
Carrier AmbiZAC08373.51,794
Carrier AmbiZAC083941,067

Other model numbers on registration ZAC0838

Registered together and sharing the same test results. Usually variants of the same unit.

Australian GEMS registration details

Registration number
ZAC0838
GEMS registration id
175630
Status
approved, available (self-reported)
Registration expires
n/a (NZ registration)
Registered for sale in
Australia, Fiji, New Zealand
Family
Carrier Ambi
Regulatory standard
[SEER Non Multi-Split <=65kW] (Air Conditioners up to 65kW) EE Regulations 2020 Schedule 2A
Test standard
AS/NZS 3823.1.1:2012
MEPS
2019
Product class
Class 8

Source: Australian Government Energy Rating (GEMS) registration data, DCCEEW via data.gov.au (CC BY 3.0 AU). Dataset published 25 September 2026; last checked 26 September 2026. Manufacturer: ahi-carrier.co.nz. How the derived figures are calculated.