c/kWh
Energy rating (cooling)
4
Heating: 2.5
Annual electricity use
550 kWh
177 cooling + 373 heating
Estimated running cost
$176 / year
$15 / month Β· $1,760 over 10 years
Capacity
2.5 kW cooling
3 kW heating

1% more electricity than the median of 191 comparable 2.5 kW reverse cycle split system registrations (543 kWh a year) in the mixed zone. Uses less than 41% of them.

Across all 3,680 air conditioner registrations sold in Australia, it uses less than 92% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the mixed zone (Richmond NSW climate: Sydney, Melbourne, Adelaide, Perth). Mixed climate zone shown by default (Sydney, Melbourne, Adelaide, Perth); switch to cold or hot. Cost = kWh Γ— 32c/kWh in AUD; change the price above to your tariff.

Daikin RXF25WVMA running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 1,171$375$3,747
Mixed zone 550$176$1,760
Hot zone 570$182$1,824

At 32c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Air conditioners that use less electricity

Same configuration and type, cooling capacity within 12% of 2.5 kW, at least 3% lower annual kWh in the mixed zone.

ModelStarsEst. cost / yrCompare
Daikin RXM20AVMA / FTXM20AVMA2.7 kW heating2.2 kW cooling380 kWh/yr5.5$122
Actron Air WRC-026DS / WRE-026DS2.7 kW heating2.6 kW cooling404 kWh/yr6.5$129
Midea MFEP26VB-W/MFEP26VB-N2.7 kW heating2.6 kW cooling404 kWh/yr6.5$129
Midea MFEP26VA-W/MFEP26VA-N2.7 kW heating2.6 kW cooling405 kWh/yr6.5$130
Actron Air WRC-026CS / WRE-026CS2.8 kW heating2.6 kW cooling410 kWh/yr6.5$131

Air conditioners similar to the Daikin RXF25WVMA

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
Carrier 38QAF026N8/42QAF026N82.8 kW heating2.5 kW cooling463 kWh/yr5$148
Midea MFAG26VB-W/MFAG26VB-N2.8 kW heating2.5 kW cooling463 kWh/yr5$148
Pioneer International HPR-09A22.6 kW heating2.5 kW cooling418 kWh/yr4$134
Carrier 42QHG026N8PB/38QUH026N8PB2.8 kW heating2.5 kW cooling463 kWh/yr5$148
Mitsubishi Heavy Industries SRC25ZSXA-W / SRK25ZSXA-W3.2 kW heating2.5 kW cooling483 kWh/yr4.5$155
Rinnai HONRTX25/HINRTX252.8 kW heating2.5 kW cooling463 kWh/yr5$148
Comfee CASG-XG26B/CASN-XG26B2.8 kW heating2.5 kW cooling463 kWh/yr5$148
Kaden KSI-2.52.8 kW heating2.5 kW cooling463 kWh/yr5$148

Compare RXF25WVMA / FTXF25WVMA with another model

Daikin RXF25WVMA specifications

Type
Reverse cycle
Configuration
Split system
Air distribution
Non-ducted
Indoor unit
Wall hung
Rated cooling capacity (35 Β°C)
2.50 kW
Cooling power input
0.53 kW
Rated heating capacity (7 Β°C)
3.00 kW
Heating power input
0.63 kW
EER, full load (tested)
4.78
COP, full load (tested)
4.83
Rated AEER
4.68
Rated ACOP
4.73
Standby power (PIA)
1.3 W
Compressor
Variable speed, Inverter
Refrigerant
R32
Power supply
Single phase
Indoor sound power
56 dB(A)
Outdoor sound power
59 dB(A)
Demand response (AS/NZS 4755)
Yes (requires additional part)
Country of manufacture
Thailand

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

Daikin RXF25WVMA zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––227339
Coldresidential4.52.01141,057
Mixedcommercial––297166
Mixedresidential4.02.5177373
Hotcommercial––67235
Hotresidential4.53.051654
Part-load test points (18 values)
h__h2_ext_cap_power_rated
720 W
c__t1_half_cap_power_rated
230 W
c__t1_have_min_cap_results
No
h__h1_half_cap_power_rated
280 W
h__h1_have_min_cap_results
No
h__h3_have_ext_cap_results
No
h__h2_have_full_cap_results
No
h__h2_have_half_cap_results
No
h__h3_have_full_cap_results
No
h__h3_have_half_cap_results
No
h__h2_ext_cap_heat_cap_rated
2300 W
h__h1_half_cap_heat_cap_rated
1500 W
h__h2_is_capable_extended_load
Yes
c__low_temp_half_cap_power_rated
190 W
c__low_temp_have_min_cap_results
No
c__t1_half_cap_cooling_cap_rated
1250 W
c__low_temp_have_half_cap_results
Yes
c__low_temp_half_cap_cooling_cap_rated
1350 W

Australian GEMS registration details

Registration number
AAC9553
GEMS registration id
173928
Status
approved, available (self-reported)
Registration expires
6 November 2030
Registered for sale in
Australia, New Zealand
Family
–
Regulatory standard
[SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
Test standard
AS/NZS 3823.1.1:2012
MEPS
2019
Product class
Class 8

Source: Australian Government Energy Rating (GEMS) registration data, DCCEEW via data.gov.au (CC BY 3.0 AU). Dataset published 25 September 2026; last checked 26 September 2026. Manufacturer: daikin.com.au. How the derived figures are calculated.