c/kWh
Energy rating (cooling)
3.5
Heating: 3
Annual electricity use
2,067 kWh
797 cooling + 1,270 heating
Estimated running cost
$661 / year
$55 / month Β· $6,614 over 10 years
Capacity
10 kW cooling
11.2 kW heating

7% less electricity than the median of 122 comparable 10 kW reverse cycle split system registrations (2,236 kWh a year) in the mixed zone. Uses less than 71% of them.

Across all 3,680 air conditioner registrations sold in Australia, it uses less than 49% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the mixed zone (Richmond NSW climate: Sydney, Melbourne, Adelaide, Perth). Mixed climate zone shown by default (Sydney, Melbourne, Adelaide, Perth); switch to cold or hot. Cost = kWh Γ— 32c/kWh in AUD; change the price above to your tariff.

Daikin RZAV100CY1 running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 3,906$1,250$12,499
Mixed zone 2,067$661$6,614
Hot zone 2,478$793$7,930

At 32c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Air conditioners that use less electricity

Same configuration and type, cooling capacity within 12% of 10 kW, at least 3% lower annual kWh in the mixed zone.

ModelStarsEst. cost / yrCompare
Daikin RZAC100C2Y1 / FCA100CVMA11.2 kW heating10 kW cooling1,492 kWh/yr2.5$477
Panasonic U-100PZ4R5 / S-1014PU3E10 kW heating10 kW cooling1,846 kWh/yr3.5$591
Carrier 38QRF090N8/42QRF090N89.5 kW heating9 kW cooling1,882 kWh/yr4$602
Midea MFAB-90WD/MFAB-90ND9.5 kW heating9 kW cooling1,882 kWh/yr4$602
Carrier 38QAF090N8/42QAF090N89.5 kW heating9 kW cooling1,882 kWh/yr4$602

Air conditioners similar to the Daikin RZAV100CY1

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
Actron Air URC-100DS / CRE-100DS10.5 kW heating10 kW cooling2,139 kWh/yr3.5$684
Fujitsu AOTG36KBTA/AUTG36KRLA11.2 kW heating10 kW cooling2,229 kWh/yr3$713
Toshiba RAV-GP1101AT8P-A/RAV-GM1101UTP-A11.2 kW heating10 kW cooling2,188 kWh/yr3.5$700
Panasonic U-100PZ3R8 / S-1014PU3E10 kW heating10 kW cooling1,918 kWh/yr3.5$614
Panasonic U-100PZ4R5 / S-1014PU3E10 kW heating10 kW cooling1,846 kWh/yr3.5$591
Toshiba RAV-GP1101ATP-A/RAV-GM1101UTP-A11.2 kW heating10 kW cooling2,202 kWh/yr3.5$705
Midea UCMI105OC/CASMI105IC10.5 kW heating10 kW cooling2,139 kWh/yr3.5$684
Mitsubishi Electric PUZ-M100VKA2-A/PLA-M100EA2-A11.2 kW heating10 kW cooling2,296 kWh/yr3$735

Compare RZAV100CY1 / FCA100CVMA with another model

Daikin RZAV100CY1 specifications

Type
Reverse cycle
Configuration
Split system
Air distribution
Non-ducted
Indoor unit
Cassette
Rated cooling capacity (35 Β°C)
10.00 kW
Cooling power input
2.38 kW
Rated heating capacity (7 Β°C)
11.20 kW
Heating power input
2.40 kW
EER, full load (tested)
4.34
COP, full load (tested)
4.86
Rated AEER
4.12
Rated ACOP
4.58
Standby power (PIA)
14.2 W
Compressor
Variable speed, Inverter
Refrigerant
R32
Power supply
Three phase
Indoor sound power
–
Outdoor sound power
–
Demand response (AS/NZS 4755)
Yes (requires additional part)
Country of manufacture
Thailand

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

Daikin RZAV100CY1 zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––1,0851,098
Coldresidential3.52.55133,393
Mixedcommercial––1,364577
Mixedresidential3.53.07971,270
Hotcommercial––3,020137
Hotresidential4.03.52,269209
Part-load test points (16 values)
h__h2_ext_cap_power_rated
2450 W
c__t1_half_cap_power_rated
840 W
c__t1_have_min_cap_results
No
h__h1_half_cap_power_rated
950 W
h__h1_have_min_cap_results
No
h__h3_have_ext_cap_results
No
h__h2_have_full_cap_results
No
h__h2_have_half_cap_results
No
h__h3_have_full_cap_results
No
h__h3_have_half_cap_results
No
h__h2_ext_cap_heat_cap_rated
9690 W
h__h1_half_cap_heat_cap_rated
5600 W
h__h2_is_capable_extended_load
Yes
c__low_temp_have_min_cap_results
No
c__t1_half_cap_cooling_cap_rated
5000 W
c__low_temp_have_half_cap_results
No

Australian GEMS registration details

Registration number
AAC9991
GEMS registration id
177704
Status
approved, available (self-reported)
Registration expires
29 March 2031
Registered for sale in
Australia, New Zealand
Family
–
Regulatory standard
[SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
Test standard
AS/NZS 3823.1.1:2012
MEPS
2019
Product class
Class 11

Source: Australian Government Energy Rating (GEMS) registration data, DCCEEW via data.gov.au (CC BY 3.0 AU). Dataset published 25 September 2026; last checked 26 September 2026. Manufacturer: daikin.com.au. How the derived figures are calculated.