c/kWh
Energy rating (cooling)
2
Heating: 1.5
Annual electricity use
4,560 kWh
1,611 cooling + 2,949 heating
Estimated running cost
$1,459 / year
$122 / month Β· $14,592 over 10 years
Capacity
15 kW cooling
18 kW heating

12% more electricity than the median of 71 comparable 16 kW reverse cycle ducted split system registrations (4,079 kWh a year) in the mixed zone. Uses less than 14% of them.

Across all 3,680 air conditioner registrations sold in Australia, it uses less than 19% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the mixed zone (Richmond NSW climate: Sydney, Melbourne, Adelaide, Perth). Mixed climate zone shown by default (Sydney, Melbourne, Adelaide, Perth); switch to cold or hot. Cost = kWh Γ— 32c/kWh in AUD; change the price above to your tariff.

Fujitsu AOTG60LATT running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 9,269$2,966$29,661
Mixed zone 4,560$1,459$14,592
Hot zone 5,081$1,626$16,259

At 32c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Air conditioners that use less electricity

Same configuration and type, cooling capacity within 12% of 15 kW, at least 3% lower annual kWh in the mixed zone.

ModelStarsEst. cost / yrCompare
Brivis AONSR15B1/AINHU15B115.7 kW heating13.6 kW cooling2,497 kWh/yr5$799
Kaden KDI48 / KDI4814 kW heating14 kW cooling2,861 kWh/yr3.5$916
Actron Air URC-140CS / LRE-140CS14.3 kW heating14 kW cooling2,885 kWh/yr3.5$923
Carrier 38QSH140D8S-1/42QSH140D8S-114.3 kW heating13.6 kW cooling2,888 kWh/yr3.5$924
Rinnai DONSR15B1/DINLR15B114.5 kW heating14 kW cooling2,930 kWh/yr3.5$938

Air conditioners similar to the Fujitsu AOTG60LATT

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
Bonaire CRC6960016/CRC696011617.5 kW heating15 kW cooling4,645 kWh/yr2$1,486
LG UU150WR2 U30/UHN150B7 N7017 kW heating15 kW cooling5,258 kWh/yr1.5$1,683
LG UU150WR3 U30/UHN150B7 N7017 kW heating15 kW cooling4,299 kWh/yr2.5$1,376
Temperzone OSA 171RLSFH / ISD 171LYX14.9 kW heating14.9 kW cooling4,880 kWh/yr1.5$1,562
Actron Air CRV15BT / EAA15BS & EFV15BS15 kW heating14.8 kW cooling3,506 kWh/yr2.5$1,122
Actron Air CRV15BT / EVV15BS15 kW heating14.8 kW cooling3,506 kWh/yr2.5$1,122
Temperzone OSAT 145RLSFH / ISDT 145LY17 kW heating14.5 kW cooling3,763 kWh/yr2.5$1,204
Hisense AUW-140U4RH1/AUD-140UX4RSH117 kW heating14.5 kW cooling3,533 kWh/yr3$1,131

Compare AOTG60LATT/ARTG60LHTA with another model

Fujitsu AOTG60LATT specifications

Type
Reverse cycle
Configuration
Split system
Air distribution
Ducted
Indoor unit
–
Rated cooling capacity (35 Β°C)
15.00 kW
Cooling power input
4.70 kW
Rated heating capacity (7 Β°C)
18.00 kW
Heating power input
5.15 kW
EER, full load (tested)
3.21
COP, full load (tested)
3.52
Rated AEER
3.15
Rated ACOP
3.46
Standby power (PIA)
16.2 W
Compressor
Variable speed, Inverter
Refrigerant
R410A
Power supply
Three phase
Indoor sound power
–
Outdoor sound power
–
Demand response (AS/NZS 4755)
No
Dimensions (WΓ—HΓ—D)
1250 Γ— 425 Γ— 490 mm
Country of manufacture
Thailand

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

Fujitsu AOTG60LATT zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––2,2712,558
Coldresidential2.01.01,0368,233
Mixedcommercial––2,8491,230
Mixedresidential2.01.51,6112,949
Hotcommercial––6,298254
Hotresidential2.52.54,687394
Part-load test points (16 values)
h__h2_ext_cap_power_rated
4250 W
c__t1_half_cap_power_rated
1820 W
c__t1_have_min_cap_results
No
h__h1_half_cap_power_rated
1930 W
h__h1_have_min_cap_results
No
h__h3_have_ext_cap_results
No
h__h2_have_full_cap_results
No
h__h2_have_half_cap_results
No
h__h3_have_full_cap_results
No
h__h3_have_half_cap_results
No
h__h2_ext_cap_heat_cap_rated
12200 W
h__h1_half_cap_heat_cap_rated
9000 W
h__h2_is_capable_extended_load
Yes
c__low_temp_have_min_cap_results
No
c__t1_half_cap_cooling_cap_rated
7500 W
c__low_temp_have_half_cap_results
No

Australian GEMS registration details

Registration number
AAC8689
GEMS registration id
167886
Status
approved, available (self-reported)
Registration expires
30 March 2030
Registered for sale in
Australia, New Zealand
Family
–
Regulatory standard
[SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
Test standard
AS/NZS 3823.1.2:2012
MEPS
2019
Product class
Class 11

Source: Australian Government Energy Rating (GEMS) registration data, DCCEEW via data.gov.au (CC BY 3.0 AU). Dataset published 25 September 2026; last checked 26 September 2026. Manufacturer: fujitsugeneral.com.au. How the derived figures are calculated.