c/kWh
Energy rating (cooling)
1
Heating: 3
Annual electricity use
450 kWh
186 cooling + 264 heating
Estimated running cost
$144 / year
$12 / month Β· $1,440 over 10 years
Capacity
2.5 kW cooling
3.5 kW heating

17% less electricity than the median of 191 comparable 2.5 kW reverse cycle split system registrations (543 kWh a year) in the mixed zone. Uses less than 91% of them.

Across all 3,680 air conditioner registrations sold in Australia, it uses less than 95% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the mixed zone (Richmond NSW climate: Sydney, Melbourne, Adelaide, Perth). Mixed climate zone shown by default (Sydney, Melbourne, Adelaide, Perth); switch to cold or hot. Cost = kWh Γ— 32c/kWh in AUD; change the price above to your tariff.

Hitachi RAC-VJ25NHAE running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 653$209$2,090
Mixed zone 450$144$1,440
Hot zone 426$136$1,363

At 32c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Air conditioners that use less electricity

Same configuration and type, cooling capacity within 12% of 2.5 kW, at least 3% lower annual kWh in the mixed zone.

ModelStarsEst. cost / yrCompare
Daikin RXM20AVMA / FTXM20AVMA2.7 kW heating2.2 kW cooling380 kWh/yr5.5$122
Midea MFEP26VB-W/MFEP26VB-N2.7 kW heating2.6 kW cooling404 kWh/yr6.5$129
Actron Air WRC-026DS / WRE-026DS2.7 kW heating2.6 kW cooling404 kWh/yr6.5$129
Midea MFEP26VA-W/MFEP26VA-N2.7 kW heating2.6 kW cooling405 kWh/yr6.5$130
Actron Air WRC-026CS / WRE-026CS2.8 kW heating2.6 kW cooling410 kWh/yr6.5$131

Air conditioners similar to the Hitachi RAC-VJ25NHAE

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
Carrier 38QAF026N8/42QAF026N82.8 kW heating2.5 kW cooling463 kWh/yr5$148
Midea MFAG26VB-W/MFAG26VB-N2.8 kW heating2.5 kW cooling463 kWh/yr5$148
Pioneer International HPR-09A22.6 kW heating2.5 kW cooling418 kWh/yr4$134
Carrier 42QHG026N8PB/38QUH026N8PB2.8 kW heating2.5 kW cooling463 kWh/yr5$148
Rinnai HONRTX25/HINRTX252.8 kW heating2.5 kW cooling463 kWh/yr5$148
Comfee CASG-XG26B/CASN-XG26B2.8 kW heating2.5 kW cooling463 kWh/yr5$148
Daikin RXM25AVMA / FTXM25AVMA3.2 kW heating2.5 kW cooling446 kWh/yr5.5$143
Kaden KSI-2.52.8 kW heating2.5 kW cooling463 kWh/yr5$148

Compare RAC-VJ25NHAE/RAI-VJ25RHAE with another model

Hitachi RAC-VJ25NHAE specifications

Type
Reverse cycle
Configuration
Split system
Air distribution
Non-ducted
Indoor unit
Cassette
Rated cooling capacity (35 Β°C)
2.50 kW
Cooling power input
0.59 kW
Rated heating capacity (7 Β°C)
3.50 kW
Heating power input
0.88 kW
EER, full load (tested)
4.53
COP, full load (tested)
4.52
Rated AEER
4.15
Rated ACOP
3.97
Standby power (PIA)
2.0 W
Compressor
Variable speed, Inverter
Refrigerant
R32
Power supply
Single phase
Indoor sound power
–
Outdoor sound power
–
Demand response (AS/NZS 4755)
Yes
Dimensions (WΓ—HΓ—D)
760 Γ— 600 Γ— 235 mm
Country of manufacture
China

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

Hitachi RAC-VJ25NHAE zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––327355
Coldresidential4.02.5120533
Mixedcommercial––29320
Mixedresidential1.03.0186264
Hotcommercial––26940
Hotresidential4.50.037155
Part-load test points (21 values)
c__t1_min_cap_power_rated
210 W
h__h2_ext_cap_power_rated
1055 W
c__t1_half_cap_power_rated
265 W
c__t1_have_min_cap_results
Yes
h__h1_half_cap_power_rated
300 W
h__h1_have_min_cap_results
No
h__h3_have_ext_cap_results
No
h__h2_have_full_cap_results
No
h__h2_have_half_cap_results
No
h__h3_have_full_cap_results
No
h__h3_have_half_cap_results
No
h__h2_ext_cap_heat_cap_rated
3200 W
h__h1_half_cap_heat_cap_rated
1750 W
h__h2_is_capable_extended_load
Yes
c__low_temp_min_cap_power_rated
170 W
c__t1_min_cap_cooling_cap_rated
970 W
c__low_temp_half_cap_power_rated
205 W
c__t1_half_cap_cooling_cap_rated
1250 W
c__low_temp_have_half_cap_results
Yes
c__low_temp_min_cap_cooling_cap_rated
1250 W
c__low_temp_half_cap_cooling_cap_rated
1350 W

Australian GEMS registration details

Registration number
AAC10270
GEMS registration id
180414
Status
approved, available (self-reported)
Registration expires
1 July 2031
Registered for sale in
Australia, Fiji, New Zealand
Family
–
Regulatory standard
[SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
Test standard
AS/NZS 3823.1.1:2012
MEPS
2019
Product class
Class 8