c/kWh
Energy rating (cooling)
3
Heating: 3
Annual electricity use
2,213 kWh
869 cooling + 1,344 heating
Estimated running cost
$708 / year
$59 / month Β· $7,082 over 10 years
Capacity
10 kW cooling
11.2 kW heating

1% less electricity than the median of 122 comparable 10 kW reverse cycle split system registrations (2,236 kWh a year) in the mixed zone. Uses less than 52% of them.

Across all 3,680 air conditioner registrations sold in Australia, it uses less than 47% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the mixed zone (Richmond NSW climate: Sydney, Melbourne, Adelaide, Perth). Mixed climate zone shown by default (Sydney, Melbourne, Adelaide, Perth); switch to cold or hot. Cost = kWh Γ— 32c/kWh in AUD; change the price above to your tariff.

Mitsubishi Heavy Industries FDT100VH running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 4,192$1,341$13,414
Mixed zone 2,213$708$7,082
Hot zone 2,722$871$8,710

At 32c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Air conditioners that use less electricity

Same configuration and type, cooling capacity within 12% of 10 kW, at least 3% lower annual kWh in the mixed zone.

ModelStarsEst. cost / yrCompare
Daikin RZAC100C2Y1 / FCA100CVMA11.2 kW heating10 kW cooling1,492 kWh/yr2.5$477
Panasonic U-100PZ4R5 / S-1014PU3E10 kW heating10 kW cooling1,846 kWh/yr3.5$591
Carrier 38QRF090N8/42QRF090N89.5 kW heating9 kW cooling1,882 kWh/yr4$602
Carrier 38QAF090N8/42QAF090N89.5 kW heating9 kW cooling1,882 kWh/yr4$602
Midea MFAB-90WD/MFAB-90ND9.5 kW heating9 kW cooling1,882 kWh/yr4$602

Air conditioners similar to the Mitsubishi Heavy Industries FDT100VH

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
Hitachi PAS-4.0UFASNQ1 / PPFC-4.0UFA1NQ11.5 kW heating10 kW cooling2,386 kWh/yr3$764
Panasonic U-100PZ4R5 / S-1014PU3E10 kW heating10 kW cooling1,846 kWh/yr3.5$591
Midea UCMI105OC/CASMI105IC10.5 kW heating10 kW cooling2,139 kWh/yr3.5$684
Actron Air URC-100DS / CRE-100DS10.5 kW heating10 kW cooling2,139 kWh/yr3.5$684
Daikin RZAC100C2Y1 / FCA100CVMA11.2 kW heating10 kW cooling1,492 kWh/yr2.5$477
Panasonic U-100PZ4R8 / S-1014PU3E10 kW heating10 kW cooling1,918 kWh/yr3.5$614
Gree GWH36AWFXH-K6DNA1A/O / GWH36AWFXH-K6DNA1A/I11 kW heating10 kW cooling2,148 kWh/yr3.5$687
Daikin RZAV100F2Y1 / FCA100CVMA12 kW heating10 kW cooling1,975 kWh/yr4$632

Compare FDT100VH / FDC(A)100VSA-W with another model

Mitsubishi Heavy Industries FDT100VH specifications

Type
Reverse cycle
Configuration
Split system
Air distribution
Non-ducted
Indoor unit
Under ceiling
Rated cooling capacity (35 Β°C)
10.00 kW
Cooling power input
2.73 kW
Rated heating capacity (7 Β°C)
11.20 kW
Heating power input
2.54 kW
EER, full load (tested)
3.81
COP, full load (tested)
4.57
Rated AEER
3.62
Rated ACOP
4.35
Standby power (PIA)
10.4 W
Compressor
Variable speed, Inverter
Refrigerant
R32
Power supply
Three phase
Indoor sound power
62 dB(A)
Outdoor sound power
69 dB(A)
Demand response (AS/NZS 4755)
Yes
Country of manufacture
Thailand

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

Mitsubishi Heavy Industries FDT100VH zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––1,1811,166
Coldresidential3.02.55523,640
Mixedcommercial––1,494605
Mixedresidential3.03.08691,344
Hotcommercial––3,343137
Hotresidential3.53.52,512210
Part-load test points (16 values)
h__h2_ext_cap_power_rated
3150 W
c__t1_half_cap_power_rated
920 W
c__t1_have_min_cap_results
No
h__h1_half_cap_power_rated
1010 W
h__h1_have_min_cap_results
No
h__h3_have_ext_cap_results
No
h__h2_have_full_cap_results
No
h__h2_have_half_cap_results
No
h__h3_have_full_cap_results
No
h__h3_have_half_cap_results
No
h__h2_ext_cap_heat_cap_rated
10000 W
h__h1_half_cap_heat_cap_rated
5600 W
h__h2_is_capable_extended_load
Yes
c__low_temp_have_min_cap_results
No
c__t1_half_cap_cooling_cap_rated
5000 W
c__low_temp_have_half_cap_results
No

Other model numbers on registration AAC9789

Registered together and sharing the same test results. Usually variants of the same unit.

Australian GEMS registration details

Registration number
AAC9789
GEMS registration id
176603
Status
approved, available (self-reported)
Registration expires
29 January 2031
Registered for sale in
Australia, Fiji, New Zealand
Family
FDT100VH / FDC(A)100VSA-W
Regulatory standard
[SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
Test standard
AS/NZS 3823.1.1:2012
MEPS
2019
Product class
Class 11

Source: Australian Government Energy Rating (GEMS) registration data, DCCEEW via data.gov.au (CC BY 3.0 AU). Dataset published 25 September 2026; last checked 26 September 2026. Manufacturer: mhiaa.com.au. How the derived figures are calculated.