Australia Β· costs in AUD

Reverse cycle split system air conditioner, cassette
Panasonic U-100PZH3R8/S-1014PU3E Air Conditioner
Panasonic U-100PZH3R8/S-1014PU3E is a 10 kW reverse cycle split system air conditioner registered under Australiaβs Energy Rating (GEMS) scheme (registration AAC9618).
- Energy rating (cooling)
- 4
- Heating: 3.5
- Annual electricity use
- 1,943 kWh
- 728 cooling + 1,215 heating
- Estimated running cost
- $622 / year
- $52 / month Β· $6,218 over 10 years
- Capacity
- 10 kW cooling
- 11.2 kW heating
13% less electricity than the median of 122 comparable 10 kW reverse cycle split system registrations (2,236 kWh a year) in the mixed zone. Uses less than 87% of them.
Across all 3,680 air conditioner registrations sold in Australia, it uses less than 52% (this compares very different sizes, so the cohort figure above is the useful one).
Annual kWh is the government label figure for a residential user in the mixed zone (Richmond NSW climate: Sydney, Melbourne, Adelaide, Perth). Mixed climate zone shown by default (Sydney, Melbourne, Adelaide, Perth); switch to cold or hot. Cost = kWh Γ 32c/kWh in AUD; change the price above to your tariff.
Panasonic U-100PZH3R8 running cost by climate zone
| Climate zone | kWh / year | Per year | 10 years |
|---|---|---|---|
| Cold zone | 3,651 | $1,168 | $11,683 |
| Mixed zone | 1,943 | $622 | $6,218 |
| Hot zone | 2,265 | $725 | $7,248 |
At 32c/kWh. Formula: cost = annual kWh Γ price. The kWh figure is the labelβs residential estimate for that zone; commercial-profile figures are in the specifications.
Air conditioners that use less electricity
Same configuration and type, cooling capacity within 12% of 10 kW, at least 3% lower annual kWh in the mixed zone.
| Model | Stars | Est. cost / yr | Compare |
|---|---|---|---|
| Daikin RZAC100C2Y1 / FCA100CVMA11.2 kW heating10 kW cooling1,492 kWh/yr | 2.5 | $477 | |
| Panasonic U-100PZ4R5 / S-1014PU3E10 kW heating10 kW cooling1,846 kWh/yr | 3.5 | $591 | |
| Carrier 38QAF090N8/42QAF090N89.5 kW heating9 kW cooling1,882 kWh/yr | 4 | $602 | |
| Midea MFAG90VB-W/MFAG90VB-N9.5 kW heating9 kW cooling1,882 kWh/yr | 4 | $602 | |
| Carrier 38QRF090N8/42QRF090N89.5 kW heating9 kW cooling1,882 kWh/yr | 4 | $602 |
Air conditioners similar to the Panasonic U-100PZH3R8
Technically comparable registrations: same configuration and type, capacity within 12%.
| Model | Stars | Est. cost / yr | Compare |
|---|---|---|---|
| Toshiba RAV-GP1101AT8P-A/RAV-GM1101UTP-A11.2 kW heating10 kW cooling2,188 kWh/yr | 3.5 | $700 | |
| Toshiba RAV-GP1101ATP-A/RAV-GM1101UTP-A11.2 kW heating10 kW cooling2,202 kWh/yr | 3.5 | $705 | |
| Midea UCMI105OC/CASMI105IC10.5 kW heating10 kW cooling2,139 kWh/yr | 3.5 | $684 | |
| Daikin RZAC100C2Y1 / FCA100CVMA11.2 kW heating10 kW cooling1,492 kWh/yr | 2.5 | $477 | |
| Daikin RZAV100F2Y1 / FCA100CVMA12 kW heating10 kW cooling1,975 kWh/yr | 4 | $632 | |
| Fujitsu AOTG36KBTA/AUTG36KRLA11.2 kW heating10 kW cooling2,229 kWh/yr | 3 | $713 | |
| Mitsubishi Electric PUZ-M100VKA2-A/PLA-M100EA2-A11.2 kW heating10 kW cooling2,296 kWh/yr | 3 | $735 | |
| Actron Air URC-100DS / CRE-100DS10.5 kW heating10 kW cooling2,139 kWh/yr | 3.5 | $684 |
Compare U-100PZH3R8/S-1014PU3E with another model
Panasonic U-100PZH3R8 specifications
- Type
- Reverse cycle
- Configuration
- Split system
- Air distribution
- Non-ducted
- Indoor unit
- Cassette
- Rated cooling capacity (35 Β°C)
- 10.00 kW
- Cooling power input
- 2.27 kW
- Rated heating capacity (7 Β°C)
- 11.20 kW
- Heating power input
- 2.24 kW
- EER, full load (tested)
- 4.24
- COP, full load (tested)
- 4.80
- Rated AEER
- 4.32
- Rated ACOP
- 4.90
- Standby power (PIA)
- 13.0 W
- Compressor
- Variable speed, Inverter
- Refrigerant
- R32
- Power supply
- Three phase
- Indoor sound power
- β
- Outdoor sound power
- β
- Demand response (AS/NZS 4755)
- Yes (mode 1 on off, mode 2 50 percent, mode 3 75 percent)
- Dimensions (WΓHΓD)
- 840 Γ 319 Γ 840 mm
- Country of manufacture
- China
Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.
Panasonic U-100PZH3R8 zoned energy rating figures
As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.
| Zone | Profile | Cooling stars | Heating stars | Cooling kWh | Heating kWh |
|---|---|---|---|---|---|
| Coldcommercial | commercial | β | β | 924 | 1,030 |
| Coldresidential | residential | 4.0 | 3.0 | 469 | 3,182 |
| Mixedcommercial | commercial | β | β | 1,187 | 550 |
| Mixedresidential | residential | 4.0 | 3.5 | 728 | 1,215 |
| Hotcommercial | commercial | β | β | 2,671 | 130 |
| Hotresidential | residential | 4.5 | 4.0 | 2,067 | 198 |
Part-load test points (22 values)
- h__h1_min_cap_power_rated
- 553 W
- h__h2_ext_cap_power_rated
- 4310 W
- c__t1_half_cap_power_rated
- 904 W
- c__t1_have_min_cap_results
- No
- h__h1_half_cap_power_rated
- 957 W
- h__h1_have_min_cap_results
- Yes
- h__h3_have_ext_cap_results
- No
- h__h2_have_full_cap_results
- No
- h__h2_have_half_cap_results
- No
- h__h3_have_full_cap_results
- No
- h__h3_have_half_cap_results
- No
- h__h1_min_cap_heat_cap_rated
- 3200 W
- h__h2_ext_cap_heat_cap_rated
- 12500 W
- h__h1_half_cap_heat_cap_rated
- 5600 W
- h__h2_is_capable_extended_load
- Yes
- c__low_temp_min_cap_power_rated
- 449 W
- c__low_temp_half_cap_power_rated
- 717 W
- c__low_temp_have_min_cap_results
- Yes
- c__t1_half_cap_cooling_cap_rated
- 5000 W
- c__low_temp_have_half_cap_results
- Yes
- c__low_temp_min_cap_cooling_cap_rated
- 3700 W
- c__low_temp_half_cap_cooling_cap_rated
- 5300 W
Australian GEMS registration details
- Registration number
- AAC9618
- GEMS registration id
- 174363
- Status
- approved, available (self-reported)
- Registration expires
- 8 December 2030
- Registered for sale in
- Australia, New Zealand
- Family
- β
- Regulatory standard
- [SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
- Test standard
- AS/NZS 3823.1.1:2012
- MEPS
- 2019
- Product class
- Class 11
Source: Australian Government Energy Rating (GEMS) registration data, DCCEEW via data.gov.au (CC BY 3.0 AU). Dataset published 19 September 2026; last checked 20 September 2026. How the derived figures are calculated.