c/kWh
Energy rating (cooling)
3
Heating: 2.5
Annual electricity use
2,765 kWh
1,007 cooling + 1,758 heating
Estimated running cost
$885 / year
$74 / month Β· $8,848 over 10 years
Capacity
12.1 kW cooling
14 kW heating

7% less electricity than the median of 76 comparable 12.5 kW reverse cycle split system registrations (2,979 kWh a year) in the mixed zone. Uses less than 70% of them.

Across all 3,680 air conditioner registrations sold in Australia, it uses less than 39% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the mixed zone (Richmond NSW climate: Sydney, Melbourne, Adelaide, Perth). Mixed climate zone shown by default (Sydney, Melbourne, Adelaide, Perth); switch to cold or hot. Cost = kWh Γ— 32c/kWh in AUD; change the price above to your tariff.

Panasonic U-125PZH3R5 running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 5,424$1,736$17,357
Mixed zone 2,765$885$8,848
Hot zone 3,141$1,005$10,051

At 32c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Air conditioners that use less electricity

Same configuration and type, cooling capacity within 12% of 12.1 kW, at least 3% lower annual kWh in the mixed zone.

ModelStarsEst. cost / yrCompare
Daikin RZAC125C2Y1 / FCA125CVMA14 kW heating12.5 kW cooling1,965 kWh/yr2.5$629
Fujitsu AOTH54KBTA/ABTH54KRTA15.5 kW heating13 kW cooling2,393 kWh/yr2.5$766
Panasonic U-125PZ4R8 / S-1014PU3E12.5 kW heating12.5 kW cooling2,509 kWh/yr3$803
Panasonic U-125PZ4R5 / S-1014PU3E12.5 kW heating12.5 kW cooling2,509 kWh/yr3$803
Kaden KDI42 / KCI4213 kW heating12.5 kW cooling2,607 kWh/yr4$834

Air conditioners similar to the Panasonic U-125PZH3R5

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
Mitsubishi Heavy Industries FDC(A)125VNP-W / FDT125VH12.1 kW heating12.1 kW cooling3,181 kWh/yr2.5$1,018
Mitsubishi Heavy Industries FDCA125VNP-W / FDT125VH12.1 kW heating12.1 kW cooling3,181 kWh/yr2.5$1,018
Samsung Electronics AC120HCADKG/SA / AC120HE4DKG/SA13 kW heating12.1 kW cooling3,007 kWh/yr2.5$962
LG UU125WR2 U30/UTN125MA NA013.5 kW heating12.1 kW cooling3,973 kWh/yr2$1,271
Mitsubishi Electric PUZ-M125VKA2-A/PLA-M125EA2-A14 kW heating12 kW cooling2,896 kWh/yr3$927
Mitsubishi Electric PUZ-M125VKA2-A/PLA-M125EA-A14 kW heating12 kW cooling2,896 kWh/yr3$927
Samsung Electronics AC120HCADKG/SA / AC120HE6DKG/SA13 kW heating12 kW cooling2,990 kWh/yr2.5$957

Other Panasonic models of similar capacity

ModelStarsEst. cost / yrCompare
Panasonic U-125PZH3R8/S-1014PT3E14 kW heating12.1 kW cooling2,765 kWh/yr3$885

Compare U-125PZH3R5/S-1014PT3E with another model

Panasonic U-125PZH3R5 specifications

Type
Reverse cycle
Configuration
Split system
Air distribution
Non-ducted
Indoor unit
Floor / ceiling
Rated cooling capacity (35 Β°C)
12.10 kW
Cooling power input
3.45 kW
Rated heating capacity (7 Β°C)
14.00 kW
Heating power input
3.70 kW
EER, full load (tested)
3.80
COP, full load (tested)
4.06
Rated AEER
3.45
Rated ACOP
3.73
Standby power (PIA)
17.0 W
Compressor
Variable speed, Inverter
Refrigerant
R32
Power supply
Single phase
Indoor sound power
–
Outdoor sound power
–
Demand response (AS/NZS 4755)
Yes (mode 1 on off, mode 2 50 percent, mode 3 75 percent)
Dimensions (WΓ—HΓ—D)
1590 Γ— 235 Γ— 690 mm
Country of manufacture
China

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

Panasonic U-125PZH3R5 zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––1,2231,452
Coldresidential3.52.06374,787
Mixedcommercial––1,591740
Mixedresidential3.02.51,0071,758
Hotcommercial––3,707168
Hotresidential3.53.52,880261
Part-load test points (22 values)
h__h1_min_cap_power_rated
555 W
h__h2_ext_cap_power_rated
5550 W
c__t1_half_cap_power_rated
1140 W
c__t1_have_min_cap_results
No
h__h1_half_cap_power_rated
1350 W
h__h1_have_min_cap_results
Yes
h__h3_have_ext_cap_results
No
h__h2_have_full_cap_results
No
h__h2_have_half_cap_results
No
h__h3_have_full_cap_results
No
h__h3_have_half_cap_results
No
h__h1_min_cap_heat_cap_rated
3200 W
h__h2_ext_cap_heat_cap_rated
14000 W
h__h1_half_cap_heat_cap_rated
7000 W
h__h2_is_capable_extended_load
Yes
c__low_temp_min_cap_power_rated
450 W
c__low_temp_half_cap_power_rated
930 W
c__low_temp_have_min_cap_results
Yes
c__t1_half_cap_cooling_cap_rated
6050 W
c__low_temp_have_half_cap_results
Yes
c__low_temp_min_cap_cooling_cap_rated
3600 W
c__low_temp_half_cap_cooling_cap_rated
6350 W

Australian GEMS registration details

Registration number
AAC9784
GEMS registration id
175928
Status
approved, available (self-reported)
Registration expires
7 February 2031
Registered for sale in
Australia, New Zealand
Family
–
Regulatory standard
[SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
Test standard
AS/NZS 3823.1.1:2012
MEPS
2019
Product class
Class 11

Source: Australian Government Energy Rating (GEMS) registration data, DCCEEW via data.gov.au (CC BY 3.0 AU). Dataset published 19 September 2026; last checked 20 September 2026. How the derived figures are calculated.