Australia Β· costs in AUD

Reverse cycle split system air conditioner, floor / ceiling
Panasonic U-125PZH3R8/S-1014PT3E Air Conditioner
Panasonic U-125PZH3R8/S-1014PT3E is a 12.1 kW reverse cycle split system air conditioner registered under Australiaβs Energy Rating (GEMS) scheme (registration AAC9785).
- Energy rating (cooling)
- 3
- Heating: 2.5
- Annual electricity use
- 2,765 kWh
- 1,007 cooling + 1,758 heating
- Estimated running cost
- $885 / year
- $74 / month Β· $8,848 over 10 years
- Capacity
- 12.1 kW cooling
- 14 kW heating
7% less electricity than the median of 76 comparable 12.5 kW reverse cycle split system registrations (2,979 kWh a year) in the mixed zone. Uses less than 70% of them.
Across all 3,680 air conditioner registrations sold in Australia, it uses less than 39% (this compares very different sizes, so the cohort figure above is the useful one).
Annual kWh is the government label figure for a residential user in the mixed zone (Richmond NSW climate: Sydney, Melbourne, Adelaide, Perth). Mixed climate zone shown by default (Sydney, Melbourne, Adelaide, Perth); switch to cold or hot. Cost = kWh Γ 32c/kWh in AUD; change the price above to your tariff.
Panasonic U-125PZH3R8 running cost by climate zone
| Climate zone | kWh / year | Per year | 10 years |
|---|---|---|---|
| Cold zone | 5,424 | $1,736 | $17,357 |
| Mixed zone | 2,765 | $885 | $8,848 |
| Hot zone | 3,141 | $1,005 | $10,051 |
At 32c/kWh. Formula: cost = annual kWh Γ price. The kWh figure is the labelβs residential estimate for that zone; commercial-profile figures are in the specifications.
Air conditioners that use less electricity
Same configuration and type, cooling capacity within 12% of 12.1 kW, at least 3% lower annual kWh in the mixed zone.
| Model | Stars | Est. cost / yr | Compare |
|---|---|---|---|
| Daikin RZAC125C2Y1 / FCA125CVMA14 kW heating12.5 kW cooling1,965 kWh/yr | 2.5 | $629 | |
| Fujitsu AOTH54KBTA/ABTH54KRTA15.5 kW heating13 kW cooling2,393 kWh/yr | 2.5 | $766 | |
| Panasonic U-125PZ4R5 / S-1014PU3E12.5 kW heating12.5 kW cooling2,509 kWh/yr | 3 | $803 | |
| Panasonic U-125PZ4R8 / S-1014PU3E12.5 kW heating12.5 kW cooling2,509 kWh/yr | 3 | $803 | |
| Kaden KDI42 / KCI4213 kW heating12.5 kW cooling2,607 kWh/yr | 4 | $834 |
Air conditioners similar to the Panasonic U-125PZH3R8
Technically comparable registrations: same configuration and type, capacity within 12%.
| Model | Stars | Est. cost / yr | Compare |
|---|---|---|---|
| Mitsubishi Heavy Industries FDC(A)125VNP-W / FDT125VH12.1 kW heating12.1 kW cooling3,181 kWh/yr | 2.5 | $1,018 | |
| Samsung Electronics AC120HCADKG/SA / AC120HE4DKG/SA13 kW heating12.1 kW cooling3,007 kWh/yr | 2.5 | $962 | |
| LG UU125WR2 U30/UTN125MA NA013.5 kW heating12.1 kW cooling3,973 kWh/yr | 2 | $1,271 | |
| Mitsubishi Heavy Industries FDCA125VNP-W / FDT125VH12.1 kW heating12.1 kW cooling3,181 kWh/yr | 2.5 | $1,018 | |
| Mitsubishi Electric PUZ-M125VKA2-A/PLA-M125EA2-A14 kW heating12 kW cooling2,896 kWh/yr | 3 | $927 | |
| Mitsubishi Electric PUZ-M125VKA2-A/PLA-M125EA-A14 kW heating12 kW cooling2,896 kWh/yr | 3 | $927 | |
| Samsung Electronics AC120HCADKG/SA / AC120HE6DKG/SA13 kW heating12 kW cooling2,990 kWh/yr | 2.5 | $957 |
Other Panasonic models of similar capacity
| Model | Stars | Est. cost / yr | Compare |
|---|---|---|---|
| Panasonic U-125PZH3R5/S-1014PT3E14 kW heating12.1 kW cooling2,765 kWh/yr | 3 | $885 |
Compare U-125PZH3R8/S-1014PT3E with another model
Panasonic U-125PZH3R8 specifications
- Type
- Reverse cycle
- Configuration
- Split system
- Air distribution
- Non-ducted
- Indoor unit
- Floor / ceiling
- Rated cooling capacity (35 Β°C)
- 12.10 kW
- Cooling power input
- 3.45 kW
- Rated heating capacity (7 Β°C)
- 14.00 kW
- Heating power input
- 3.70 kW
- EER, full load (tested)
- 3.80
- COP, full load (tested)
- 4.06
- Rated AEER
- 3.45
- Rated ACOP
- 3.73
- Standby power (PIA)
- 17.0 W
- Compressor
- Variable speed, Inverter
- Refrigerant
- R32
- Power supply
- Three phase
- Indoor sound power
- β
- Outdoor sound power
- β
- Demand response (AS/NZS 4755)
- Yes (mode 1 on off, mode 2 50 percent, mode 3 75 percent)
- Dimensions (WΓHΓD)
- 1590 Γ 235 Γ 690 mm
- Country of manufacture
- China
Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.
Panasonic U-125PZH3R8 zoned energy rating figures
As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.
| Zone | Profile | Cooling stars | Heating stars | Cooling kWh | Heating kWh |
|---|---|---|---|---|---|
| Coldcommercial | commercial | β | β | 1,223 | 1,452 |
| Coldresidential | residential | 3.5 | 2.0 | 637 | 4,787 |
| Mixedcommercial | commercial | β | β | 1,591 | 740 |
| Mixedresidential | residential | 3.0 | 2.5 | 1,007 | 1,758 |
| Hotcommercial | commercial | β | β | 3,707 | 168 |
| Hotresidential | residential | 3.5 | 3.5 | 2,880 | 261 |
Part-load test points (22 values)
- h__h1_min_cap_power_rated
- 555 W
- h__h2_ext_cap_power_rated
- 5550 W
- c__t1_half_cap_power_rated
- 1140 W
- c__t1_have_min_cap_results
- No
- h__h1_half_cap_power_rated
- 1350 W
- h__h1_have_min_cap_results
- Yes
- h__h3_have_ext_cap_results
- No
- h__h2_have_full_cap_results
- No
- h__h2_have_half_cap_results
- No
- h__h3_have_full_cap_results
- No
- h__h3_have_half_cap_results
- No
- h__h1_min_cap_heat_cap_rated
- 3200 W
- h__h2_ext_cap_heat_cap_rated
- 14000 W
- h__h1_half_cap_heat_cap_rated
- 7000 W
- h__h2_is_capable_extended_load
- Yes
- c__low_temp_min_cap_power_rated
- 450 W
- c__low_temp_half_cap_power_rated
- 930 W
- c__low_temp_have_min_cap_results
- Yes
- c__t1_half_cap_cooling_cap_rated
- 6050 W
- c__low_temp_have_half_cap_results
- Yes
- c__low_temp_min_cap_cooling_cap_rated
- 3600 W
- c__low_temp_half_cap_cooling_cap_rated
- 6350 W
Australian GEMS registration details
- Registration number
- AAC9785
- GEMS registration id
- 175929
- Status
- approved, available (self-reported)
- Registration expires
- 11 February 2031
- Registered for sale in
- Australia, New Zealand
- Family
- β
- Regulatory standard
- [SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
- Test standard
- AS/NZS 3823.1.1:2012
- MEPS
- 2019
- Product class
- Class 11