c/kWh
Energy rating (cooling)
3
Heating: 2.5
Annual electricity use
3,270 kWh
1,203 cooling + 2,067 heating
Estimated running cost
$1,046 / year
$87 / month Β· $10,464 over 10 years
Capacity
13.4 kW cooling
15.5 kW heating

8% less electricity than the median of 117 comparable 14 kW reverse cycle ducted split system registrations (3,549 kWh a year) in the mixed zone. Uses less than 80% of them.

Across all 3,638 air conditioner registrations sold in Australia, it uses less than 32% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the mixed zone (Richmond NSW climate: Sydney, Melbourne, Adelaide, Perth). Mixed climate zone shown by default (Sydney, Melbourne, Adelaide, Perth); switch to cold or hot. Cost = kWh Γ— 32c/kWh in AUD; change the price above to your tariff.

Panasonic U-140PZH3R8 running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 6,332$2,026$20,262
Mixed zone 3,270$1,046$10,464
Hot zone 3,783$1,211$12,106

At 32c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Air conditioners that use less electricity

Same configuration and type, cooling capacity within 12% of 13.4 kW, at least 3% lower annual kWh in the mixed zone.

ModelStarsEst. cost / yrCompare
Panasonic U-125PZ3R8 / S-1014PF3E12.1 kW heating12.1 kW cooling1,681 kWh/yr1.5$538
Brivis AONSR13B1/AINHU13B113.8 kW heating12 kW cooling2,209 kWh/yr4$707
Brivis AONSR15B1/AINHU15B115.7 kW heating13.6 kW cooling2,497 kWh/yr5$799
Midea DUCMI125IHB/UCMI125OB13 kW heating12.5 kW cooling2,556 kWh/yr3.5$818
Rinnai DONSR13B1/DINLR13B113 kW heating12.5 kW cooling2,559 kWh/yr3.5$819

Air conditioners similar to the Panasonic U-140PZH3R8

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
Bonaire CRC6960014/CRC696011416 kW heating13.5 kW cooling3,952 kWh/yr2.5$1,265
Braemar KCHV160D1B/KGHV200A1S17 kW heating13.2 kW cooling3,628 kWh/yr2.5$1,161
Braemar KCHV160D1B/KGHV200A1T17 kW heating13.2 kW cooling3,628 kWh/yr2.5$1,161
Brivis AONSR15B1/AINHU15B115.7 kW heating13.6 kW cooling2,497 kWh/yr5$799
Carrier 38QSH140D8S-1/42QSH140D8S-114.3 kW heating13.6 kW cooling2,888 kWh/yr3.5$924
Actron Air CRV13AS / EVV13AS13.4 kW heating13.2 kW cooling4,893 kWh/yr2.5$1,566
Actron Air CRV13AS / EAA13AS & EFV13AS13.4 kW heating13.2 kW cooling4,893 kWh/yr2.5$1,566
Carrier 38QSM140D8S/42QSM140D8S14.5 kW heating13.6 kW cooling2,979 kWh/yr3$953

Compare U-140PZH3R8/S-1014PF3E with another model

Panasonic U-140PZH3R8 specifications

Type
Reverse cycle
Configuration
Split system
Air distribution
Ducted
Indoor unit
–
Rated cooling capacity (35 Β°C)
13.40 kW
Cooling power input
–
Rated heating capacity (7 Β°C)
15.50 kW
Heating power input
–
EER, full load (tested)
3.54
COP, full load (tested)
3.62
Rated AEER
3.34
Rated ACOP
3.40
Standby power (PIA)
15.0 W
Compressor
Variable speed, Inverter
Refrigerant
R32
Power supply
Three phase
Indoor sound power
–
Outdoor sound power
–
Demand response (AS/NZS 4755)
Yes
Country of manufacture
China

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

Panasonic U-140PZH3R8 zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––1,5371,702
Coldresidential3.02.07645,568
Mixedcommercial––1,977878
Mixedresidential3.02.51,2032,067
Hotcommercial––4,551191
Hotresidential3.03.03,484299
Part-load test points (22 values)
h__h1_min_cap_power_rated
660 W
h__h2_ext_cap_power_rated
5600 W
c__t1_half_cap_power_rated
1400 W
c__t1_have_min_cap_results
No
h__h1_half_cap_power_rated
1550 W
h__h1_have_min_cap_results
Yes
h__h3_have_ext_cap_results
No
h__h2_have_full_cap_results
No
h__h2_have_half_cap_results
No
h__h3_have_full_cap_results
No
h__h3_have_half_cap_results
No
h__h1_min_cap_heat_cap_rated
3400 W
h__h2_ext_cap_heat_cap_rated
15000 W
h__h1_half_cap_heat_cap_rated
7750 W
h__h2_is_capable_extended_load
Yes
c__low_temp_min_cap_power_rated
550 W
c__low_temp_half_cap_power_rated
1190 W
c__low_temp_have_min_cap_results
Yes
c__t1_half_cap_cooling_cap_rated
6700 W
c__low_temp_have_half_cap_results
Yes
c__low_temp_min_cap_cooling_cap_rated
3600 W
c__low_temp_half_cap_cooling_cap_rated
7200 W

Australian GEMS registration details

Registration number
AAC9635
GEMS registration id
–
Status
approved
Registration expires
8 December 2030
Registered for sale in
Australia, New Zealand
Family
–
Regulatory standard
Greenhouse and Energy Minimum Standards (Air Conditioners up to 65kW) Determination 2019
Test standard
AS/NZS 3823.1.2:2012
MEPS
2019
Product class
11

Source: Australian Government Energy Rating (GEMS) registration data, DCCEEW via data.gov.au (CC BY 3.0 AU). Dataset published 28 October 2026; last checked 29 October 2026. How the derived figures are calculated.