Australia Β· costs in AUD

Reverse cycle split system air conditioner
Panasonic U-140PZH3R8/S-1014PF3E Air Conditioner
Panasonic U-140PZH3R8/S-1014PF3E is a 13.4 kW reverse cycle ducted split system air conditioner registered under Australiaβs Energy Rating (GEMS) scheme (registration AAC9635).
- Energy rating (cooling)
- 3
- Heating: 2.5
- Annual electricity use
- 3,270 kWh
- 1,203 cooling + 2,067 heating
- Estimated running cost
- $1,046 / year
- $87 / month Β· $10,464 over 10 years
- Capacity
- 13.4 kW cooling
- 15.5 kW heating
8% less electricity than the median of 117 comparable 14 kW reverse cycle ducted split system registrations (3,549 kWh a year) in the mixed zone. Uses less than 80% of them.
Across all 3,680 air conditioner registrations sold in Australia, it uses less than 32% (this compares very different sizes, so the cohort figure above is the useful one).
Annual kWh is the government label figure for a residential user in the mixed zone (Richmond NSW climate: Sydney, Melbourne, Adelaide, Perth). Mixed climate zone shown by default (Sydney, Melbourne, Adelaide, Perth); switch to cold or hot. Cost = kWh Γ 32c/kWh in AUD; change the price above to your tariff.
Panasonic U-140PZH3R8 running cost by climate zone
| Climate zone | kWh / year | Per year | 10 years |
|---|---|---|---|
| Cold zone | 6,332 | $2,026 | $20,262 |
| Mixed zone | 3,270 | $1,046 | $10,464 |
| Hot zone | 3,783 | $1,211 | $12,106 |
At 32c/kWh. Formula: cost = annual kWh Γ price. The kWh figure is the labelβs residential estimate for that zone; commercial-profile figures are in the specifications.
Air conditioners that use less electricity
Same configuration and type, cooling capacity within 12% of 13.4 kW, at least 3% lower annual kWh in the mixed zone.
| Model | Stars | Est. cost / yr | Compare |
|---|---|---|---|
| Panasonic U-125PZ3R8 / S-1014PF3E12.1 kW heating12.1 kW cooling1,681 kWh/yr | 1.5 | $538 | |
| Brivis AONSR13B1/AINHU13B113.8 kW heating12 kW cooling2,209 kWh/yr | 4 | $707 | |
| Brivis AONSR15B1/AINHU15B115.7 kW heating13.6 kW cooling2,497 kWh/yr | 5 | $799 | |
| Midea DUCMI125IHB/UCMI125OB13 kW heating12.5 kW cooling2,556 kWh/yr | 3.5 | $818 | |
| Rinnai DONSR13B1/DINLR13B113 kW heating12.5 kW cooling2,559 kWh/yr | 3.5 | $819 |
Air conditioners similar to the Panasonic U-140PZH3R8
Technically comparable registrations: same configuration and type, capacity within 12%.
| Model | Stars | Est. cost / yr | Compare |
|---|---|---|---|
| Bonaire CRC6960014/CRC696011416 kW heating13.5 kW cooling3,952 kWh/yr | 2.5 | $1,265 | |
| Braemar KCHV160D1B/KGHV200A1S17 kW heating13.2 kW cooling3,628 kWh/yr | 2.5 | $1,161 | |
| Braemar KCHV160D1B/KGHV200A1T17 kW heating13.2 kW cooling3,628 kWh/yr | 2.5 | $1,161 | |
| Brivis AONSR15B1/AINHU15B115.7 kW heating13.6 kW cooling2,497 kWh/yr | 5 | $799 | |
| Carrier 38QSH140D8S-1/42QSH140D8S-114.3 kW heating13.6 kW cooling2,888 kWh/yr | 3.5 | $924 | |
| Actron Air CRV13AS / EVV13AS13.4 kW heating13.2 kW cooling4,893 kWh/yr | 2.5 | $1,566 | |
| Actron Air CRV13AS / EAA13AS & EFV13AS13.4 kW heating13.2 kW cooling4,893 kWh/yr | 2.5 | $1,566 | |
| Carrier 38QSM140D8S/42QSM140D8S14.5 kW heating13.6 kW cooling2,979 kWh/yr | 3 | $953 |
Compare U-140PZH3R8/S-1014PF3E with another model
Panasonic U-140PZH3R8 specifications
- Type
- Reverse cycle
- Configuration
- Split system
- Air distribution
- Ducted
- Indoor unit
- β
- Rated cooling capacity (35 Β°C)
- 13.40 kW
- Cooling power input
- 3.96 kW
- Rated heating capacity (7 Β°C)
- 15.50 kW
- Heating power input
- 4.51 kW
- EER, full load (tested)
- 3.54
- COP, full load (tested)
- 3.62
- Rated AEER
- 3.34
- Rated ACOP
- 3.40
- Standby power (PIA)
- 15.0 W
- Compressor
- Variable speed, Inverter
- Refrigerant
- R32
- Power supply
- Three phase
- Indoor sound power
- β
- Outdoor sound power
- β
- Demand response (AS/NZS 4755)
- Yes (mode 1 on off, mode 2 50 percent, mode 3 75 percent)
- Dimensions (WΓHΓD)
- 1400 Γ 290 Γ 700 mm
- Country of manufacture
- China
Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.
Panasonic U-140PZH3R8 zoned energy rating figures
As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.
| Zone | Profile | Cooling stars | Heating stars | Cooling kWh | Heating kWh |
|---|---|---|---|---|---|
| Coldcommercial | commercial | β | β | 1,537 | 1,702 |
| Coldresidential | residential | 3.0 | 2.0 | 764 | 5,568 |
| Mixedcommercial | commercial | β | β | 1,977 | 878 |
| Mixedresidential | residential | 3.0 | 2.5 | 1,203 | 2,067 |
| Hotcommercial | commercial | β | β | 4,551 | 191 |
| Hotresidential | residential | 3.0 | 3.0 | 3,484 | 299 |
Part-load test points (22 values)
- h__h1_min_cap_power_rated
- 660 W
- h__h2_ext_cap_power_rated
- 5600 W
- c__t1_half_cap_power_rated
- 1400 W
- c__t1_have_min_cap_results
- No
- h__h1_half_cap_power_rated
- 1550 W
- h__h1_have_min_cap_results
- Yes
- h__h3_have_ext_cap_results
- No
- h__h2_have_full_cap_results
- No
- h__h2_have_half_cap_results
- No
- h__h3_have_full_cap_results
- No
- h__h3_have_half_cap_results
- No
- h__h1_min_cap_heat_cap_rated
- 3400 W
- h__h2_ext_cap_heat_cap_rated
- 15000 W
- h__h1_half_cap_heat_cap_rated
- 7750 W
- h__h2_is_capable_extended_load
- Yes
- c__low_temp_min_cap_power_rated
- 550 W
- c__low_temp_half_cap_power_rated
- 1190 W
- c__low_temp_have_min_cap_results
- Yes
- c__t1_half_cap_cooling_cap_rated
- 6700 W
- c__low_temp_have_half_cap_results
- Yes
- c__low_temp_min_cap_cooling_cap_rated
- 3600 W
- c__low_temp_half_cap_cooling_cap_rated
- 7200 W
Australian GEMS registration details
- Registration number
- AAC9635
- GEMS registration id
- 174374
- Status
- approved, available (self-reported)
- Registration expires
- 8 December 2030
- Registered for sale in
- Australia, New Zealand
- Family
- β
- Regulatory standard
- [SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
- Test standard
- AS/NZS 3823.1.2:2012
- MEPS
- 2019
- Product class
- Class 11
Source: Australian Government Energy Rating (GEMS) registration data, DCCEEW via data.gov.au (CC BY 3.0 AU). Dataset published 19 September 2026; last checked 20 September 2026. How the derived figures are calculated.