c/kWh
Energy rating (cooling)
3.5
Heating: 3
Annual electricity use
1,449 kWh
561 cooling + 888 heating
Estimated running cost
$464 / year
$39 / month Β· $4,637 over 10 years
Capacity
7.5 kW cooling
7.4 kW heating

Only 3 comparable registrations in this cohort, so no percentile is shown.

Across all 3,680 air conditioner registrations sold in Australia, it uses less than 65% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the mixed zone (Richmond NSW climate: Sydney, Melbourne, Adelaide, Perth). Mixed climate zone shown by default (Sydney, Melbourne, Adelaide, Perth); switch to cold or hot. Cost = kWh Γ— 32c/kWh in AUD; change the price above to your tariff.

Rinnai MON3H07B running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 2,647$847$8,470
Mixed zone 1,449$464$4,637
Hot zone 1,722$551$5,510

At 32c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Air conditioners similar to the Rinnai MON3H07B

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
Braemar MCMX080D104B9 kW heating8 kW cooling2,716 kWh/yr1$869

Other Rinnai models of similar capacity

ModelStarsEst. cost / yrCompare
Rinnai MON3H07B7.4 kW heating7.5 kW cooling1,460 kWh/yr3.5$467

Compare MON3H07B with another model

Rinnai MON3H07B specifications

Type
Reverse cycle
Configuration
Multi-split / VRF
Air distribution
Ducted or non-ducted
Indoor unit
–
Rated cooling capacity (35 Β°C)
7.50 kW
Cooling power input
1.98 kW
Rated heating capacity (7 Β°C)
7.40 kW
Heating power input
1.59 kW
EER, full load (tested)
3.80
COP, full load (tested)
4.66
Rated AEER
3.71
Rated ACOP
4.54
Standby power (PIA)
12.0 W
Compressor
Variable speed, Inverter
Refrigerant
R32
Power supply
Single phase
Indoor sound power
–
Outdoor sound power
66 dB(A)
Demand response (AS/NZS 4755)
Yes
Country of manufacture
China

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

Rinnai MON3H07B zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––338743
Coldresidential3.52.53582,289
Mixedcommercial––649401
Mixedresidential3.53.0561888
Hotcommercial––1,76099
Hotresidential4.53.51,572150
Part-load test points (25 values)
c__t1_min_cap_power_rated
660 W
h__h1_min_cap_power_rated
380 W
h__h2_ext_cap_power_rated
2550 W
c__t1_half_cap_power_rated
760 W
c__t1_have_min_cap_results
Yes
h__h1_half_cap_power_rated
650 W
h__h1_have_min_cap_results
Yes
h__h3_have_ext_cap_results
No
h__h2_have_full_cap_results
No
h__h2_have_half_cap_results
No
h__h3_have_full_cap_results
No
h__h3_have_half_cap_results
No
h__h1_min_cap_heat_cap_rated
2035 W
h__h2_ext_cap_heat_cap_rated
7800 W
h__h1_half_cap_heat_cap_rated
3380 W
h__h2_is_capable_extended_load
Yes
c__low_temp_min_cap_power_rated
380 W
c__t1_min_cap_cooling_cap_rated
3255 W
c__low_temp_full_cap_power_rated
1809.72 W
c__low_temp_half_cap_power_rated
510 W
c__t1_half_cap_cooling_cap_rated
3700 W
c__low_temp_have_half_cap_results
Yes
c__low_temp_min_cap_cooling_cap_rated
2990 W
c__low_temp_full_cap_cooling_cap_rated
8077.5 W
c__low_temp_half_cap_cooling_cap_rated
3650 W

2 model numbers on 2 other registrations. Variants registered separately can carry different star ratings and energy figures; check the registration number on the label.

ModelRegistrationStarskWh / yr
MON3H07BAAC81773.51,460
MON3H07B1LAAAC90793.51,455

Australian GEMS registration details

Registration number
AAC6874
GEMS registration id
148797
Status
approved, available (self-reported)
Registration expires
16 August 2027
Registered for sale in
Australia, Fiji, New Zealand
Family
–
Regulatory standard
[SEER Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
Test standard
AS/NZS 3823.1.4:2012
MEPS
2019
Product class
Class 19

Source: Australian Government Energy Rating (GEMS) registration data, DCCEEW via data.gov.au (CC BY 3.0 AU). Dataset published 25 September 2026; last checked 26 September 2026. Manufacturer: rinnai.com.au. How the derived figures are calculated.