c/kWh
Energy rating (cooling)
3
Heating: 3
Annual electricity use
1,644 kWh
623 cooling + 1,021 heating
Estimated running cost
$526 / year
$44 / month Β· $5,261 over 10 years
Capacity
7.3 kW cooling
8.3 kW heating

1% less electricity than the median of 10 comparable 7 kW reverse cycle fixed registrations (1,661 kWh a year) in the mixed zone. Uses less than 50% of them.

Across all 3,680 air conditioner registrations sold in Australia, it uses less than 59% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the mixed zone (Richmond NSW climate: Sydney, Melbourne, Adelaide, Perth). Mixed climate zone shown by default (Sydney, Melbourne, Adelaide, Perth); switch to cold or hot. Cost = kWh Γ— 32c/kWh in AUD; change the price above to your tariff.

Braemar NCHV07D13B running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 3,237$1,036$10,358
Mixed zone 1,644$526$5,261
Hot zone 1,953$625$6,250

At 32c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Air conditioners that use less electricity

Same configuration and type, cooling capacity within 12% of 7.3 kW, at least 3% lower annual kWh in the mixed zone.

ModelStarsEst. cost / yrCompare
Haier 4U71S2PR1FA7.1 kW heating7.1 kW cooling1,445 kWh/yr3$462
Rinnai MON3H07B1LA7.3 kW heating7.2 kW cooling1,455 kWh/yr3.5$466
Hitachi RAM-G70N4HCE8.5 kW heating7 kW cooling1,536 kWh/yr4$492

Air conditioners similar to the Braemar NCHV07D13B

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
Rinnai MON3H07B1LA7.3 kW heating7.2 kW cooling1,455 kWh/yr3.5$466
Actron Air MRC-071AS-37.8 kW heating7.1 kW cooling1,605 kWh/yr3$514
Haier 4U71S2PR1FA7.1 kW heating7.1 kW cooling1,445 kWh/yr3$462
Haier 4U71S2PR1FA8 kW heating7.1 kW cooling1,833 kWh/yr2$587
Hitachi RAM-G70N4HCE8.5 kW heating7 kW cooling1,536 kWh/yr4$492
Daikin 4MXM68R2VMA8.6 kW heating6.8 kW cooling1,678 kWh/yr3.5$537

Other Braemar models of similar capacity

ModelStarsEst. cost / yrCompare
Braemar NCHV72D138.5 kW heating7.3 kW cooling1,810 kWh/yr2$579
Braemar NCHV72D138.6 kW heating7.2 kW cooling1,797 kWh/yr2$575

Compare NCHV07D13B with another model

Braemar NCHV07D13B specifications

Type
Reverse cycle
Configuration
Fixed
Air distribution
Ducted or non-ducted
Indoor unit
–
Rated cooling capacity (35 Β°C)
7.30 kW
Cooling power input
1.96 kW
Rated heating capacity (7 Β°C)
8.30 kW
Heating power input
2.00 kW
EER, full load (tested)
3.75
COP, full load (tested)
4.27
Rated AEER
3.67
Rated ACOP
4.09
Standby power (PIA)
8.1 W
Compressor
Variable speed, Inverter
Refrigerant
R32
Power supply
Single phase
Indoor sound power
–
Outdoor sound power
66.4 dB(A)
Demand response (AS/NZS 4755)
Yes
Country of manufacture
China

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

Braemar NCHV07D13B zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––844890
Coldresidential3.02.03962,841
Mixedcommercial––1,068453
Mixedresidential3.03.06231,021
Hotcommercial––2,389101
Hotresidential3.53.51,797156
Part-load test points (20 values)
h__h2_ext_cap_power_rated
2200 W
c__t1_half_cap_power_rated
655 W
c__t1_have_min_cap_results
No
h__h1_half_cap_power_rated
740 W
h__h1_have_min_cap_results
No
h__h3_have_ext_cap_results
No
h__h2_have_full_cap_results
No
h__h2_have_half_cap_results
No
h__h3_have_full_cap_results
No
h__h3_have_half_cap_results
No
h__h2_ext_cap_heat_cap_rated
6800 W
h__h1_half_cap_heat_cap_rated
4150 W
h__h2_is_capable_extended_load
Yes
c__low_temp_full_cap_power_rated
1791.44 W
c__low_temp_half_cap_power_rated
598.6700000000001 W
c__low_temp_have_min_cap_results
No
c__t1_half_cap_cooling_cap_rated
3650 W
c__low_temp_have_half_cap_results
No
c__low_temp_full_cap_cooling_cap_rated
7862.099999999999 W
c__low_temp_half_cap_cooling_cap_rated
3931.0499999999997 W

Australian GEMS registration details

Registration number
AAC7934
GEMS registration id
157017
Status
approved, available (self-reported)
Registration expires
4 December 2028
Registered for sale in
Australia, Fiji, New Zealand
Family
–
Regulatory standard
[SEER Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
Test standard
AS/NZS 3823.1.4:2012
MEPS
2019
Product class
Class 19

Source: Australian Government Energy Rating (GEMS) registration data, DCCEEW via data.gov.au (CC BY 3.0 AU). Dataset published 25 September 2026; last checked 26 September 2026. Manufacturer: gree.com. How the derived figures are calculated.