c/kWh
Energy rating (cooling)
2
Heating: 3
Annual electricity use
1,797 kWh
747 cooling + 1,050 heating
Estimated running cost
$575 / year
$48 / month Β· $5,750 over 10 years
Capacity
7.2 kW cooling
8.6 kW heating

8% more electricity than the median of 10 comparable 7 kW reverse cycle fixed registrations (1,661 kWh a year) in the mixed zone. Uses less than 20% of them.

Across all 3,680 air conditioner registrations sold in Australia, it uses less than 55% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the mixed zone (Richmond NSW climate: Sydney, Melbourne, Adelaide, Perth). Mixed climate zone shown by default (Sydney, Melbourne, Adelaide, Perth); switch to cold or hot. Cost = kWh Γ— 32c/kWh in AUD; change the price above to your tariff.

Braemar NCHV72D13 running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 3,278$1,049$10,490
Mixed zone 1,797$575$5,750
Hot zone 2,299$736$7,357

At 32c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Air conditioners that use less electricity

Same configuration and type, cooling capacity within 12% of 7.2 kW, at least 3% lower annual kWh in the mixed zone.

ModelStarsEst. cost / yrCompare
Haier 4U71S2PR1FA7.1 kW heating7.1 kW cooling1,445 kWh/yr3$462
Rinnai MON3H07B1LA7.3 kW heating7.2 kW cooling1,455 kWh/yr3.5$466
Hitachi RAM-G70N4HCE8.5 kW heating7 kW cooling1,536 kWh/yr4$492
Actron Air MRC-071AS-37.8 kW heating7.1 kW cooling1,605 kWh/yr3$514
Braemar NCHV07D13B8.3 kW heating7.3 kW cooling1,644 kWh/yr3$526

Air conditioners similar to the Braemar NCHV72D13

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
Haier 4U71S2PR1FA8 kW heating7.1 kW cooling1,833 kWh/yr2$587
Actron Air MRC-071AS-37.8 kW heating7.1 kW cooling1,605 kWh/yr3$514
Rinnai MON3H07B1LA7.3 kW heating7.2 kW cooling1,455 kWh/yr3.5$466
Haier 4U71S2PR1FA7.1 kW heating7.1 kW cooling1,445 kWh/yr3$462
Hitachi RAM-G70N4HCE8.5 kW heating7 kW cooling1,536 kWh/yr4$492
Daikin 4MXM68R2VMA8.6 kW heating6.8 kW cooling1,678 kWh/yr3.5$537

Other Braemar models of similar capacity

ModelStarsEst. cost / yrCompare
Braemar NCHV07D13B8.3 kW heating7.3 kW cooling1,644 kWh/yr3$526
Braemar NCHV72D138.5 kW heating7.3 kW cooling1,810 kWh/yr2$579

Compare NCHV72D13 with another model

Braemar NCHV72D13 specifications

Type
Reverse cycle
Configuration
Fixed
Air distribution
Ducted or non-ducted
Indoor unit
–
Rated cooling capacity (35 Β°C)
7.15 kW
Cooling power input
1.90 kW
Rated heating capacity (7 Β°C)
8.60 kW
Heating power input
1.90 kW
EER, full load (tested)
3.72
COP, full load (tested)
4.50
Rated AEER
3.67
Rated ACOP
4.42
Standby power (PIA)
13.7 W
Compressor
Variable speed, Inverter
Refrigerant
R32
Power supply
Single phase
Indoor sound power
–
Outdoor sound power
57.6 dB(A)
Demand response (AS/NZS 4755)
Yes
Country of manufacture
Australia

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

Braemar NCHV72D13 zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––1,074905
Coldresidential2.02.54932,785
Mixedcommercial––1,329480
Mixedresidential2.03.07471,050
Hotcommercial––2,866117
Hotresidential2.53.52,122177
Part-load test points (20 values)
h__h2_ext_cap_power_rated
2500 W
c__t1_half_cap_power_rated
830 W
c__t1_have_min_cap_results
No
h__h1_half_cap_power_rated
720 W
h__h1_have_min_cap_results
No
h__h3_have_ext_cap_results
No
h__h2_have_full_cap_results
No
h__h2_have_half_cap_results
No
h__h3_have_full_cap_results
No
h__h3_have_half_cap_results
No
h__h2_ext_cap_heat_cap_rated
7900 W
h__h1_half_cap_heat_cap_rated
3900 W
h__h2_is_capable_extended_load
Yes
c__low_temp_full_cap_power_rated
1736.6000000000001 W
c__low_temp_half_cap_power_rated
758.62 W
c__low_temp_have_min_cap_results
No
c__t1_half_cap_cooling_cap_rated
3400 W
c__low_temp_have_half_cap_results
No
c__low_temp_full_cap_cooling_cap_rated
7700.549999999999 W
c__low_temp_half_cap_cooling_cap_rated
3661.7999999999997 W

1 model numbers on 1 other registration. Variants registered separately can carry different star ratings and energy figures; check the registration number on the label.

ModelRegistrationStarskWh / yr
NCHV72D13AAC756821,810

Australian GEMS registration details

Registration number
AAC6657
GEMS registration id
144953
Status
approved, available (self-reported)
Registration expires
4 May 2027
Registered for sale in
Australia, Fiji, New Zealand
Family
–
Regulatory standard
[SEER Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
Test standard
AS/NZS 3823.1.4:2012
MEPS
2019
Product class
Class 19

Source: Australian Government Energy Rating (GEMS) registration data, DCCEEW via data.gov.au (CC BY 3.0 AU). Dataset published 25 September 2026; last checked 26 September 2026. Manufacturer: gree.com. How the derived figures are calculated.