Australia Β· costs in AUD

Reverse cycle air conditioner
Haier 4U71S2PR1FA Air Conditioner
Haier 4U71S2PR1FA is a 7.1 kW reverse cycle air conditioner registered under Australiaβs Energy Rating (GEMS) scheme (registration AAC9389).
- Energy rating (cooling)
- 3
- Heating: 3
- Annual electricity use
- 1,445 kWh
- 550 cooling + 895 heating
- Estimated running cost
- $462 / year
- $39 / month Β· $4,624 over 10 years
- Capacity
- 7.1 kW cooling
- 7.1 kW heating
12% less electricity than the median of 9 comparable 7 kW reverse cycle registrations (1,644 kWh a year) in the mixed zone. Uses less than 89% of them.
Across all 3,638 air conditioner registrations sold in Australia, it uses less than 66% (this compares very different sizes, so the cohort figure above is the useful one).
Annual kWh is the government label figure for a residential user in the mixed zone (Richmond NSW climate: Sydney, Melbourne, Adelaide, Perth). Mixed climate zone shown by default (Sydney, Melbourne, Adelaide, Perth); switch to cold or hot. Cost = kWh Γ 32c/kWh in AUD; change the price above to your tariff.
Haier 4U71S2PR1FA running cost by climate zone
| Climate zone | kWh / year | Per year | 10 years |
|---|---|---|---|
| Cold zone | 2,634 | $843 | $8,429 |
| Mixed zone | 1,445 | $462 | $4,624 |
| Hot zone | 1,638 | $524 | $5,242 |
At 32c/kWh. Formula: cost = annual kWh Γ price. The kWh figure is the labelβs residential estimate for that zone; commercial-profile figures are in the specifications.
Air conditioners similar to the Haier 4U71S2PR1FA
Technically comparable registrations: same configuration and type, capacity within 12%.
| Model | Stars | Est. cost / yr | Compare |
|---|---|---|---|
| Actron Air MRC-071AS-37.8 kW heating7.1 kW cooling1,605 kWh/yr | 3 | $514 | |
| Braemar NCHV72D138.6 kW heating7.2 kW cooling1,797 kWh/yr | 2 | $575 | |
| Rinnai MON3H07B1LA7.3 kW heating7.2 kW cooling1,455 kWh/yr | 3.5 | $466 | |
| Hitachi RAM-G70N4HCE8.5 kW heating7 kW cooling1,536 kWh/yr | 4 | $492 | |
| Braemar NCHV07D13B8.3 kW heating7.3 kW cooling1,644 kWh/yr | 3 | $526 | |
| Daikin 4MXM68R2VMA8.6 kW heating6.8 kW cooling1,678 kWh/yr | 3.5 | $537 | |
| Daikin 4MXM68RVMA8.6 kW heating6.8 kW cooling1,678 kWh/yr | 3.5 | $537 | |
| Rinnai MON3H07B7.4 kW heating7.5 kW cooling1,449 kWh/yr | 3.5 | $464 |
Compare 4U71S2PR1FA with another model
Haier 4U71S2PR1FA specifications
- Type
- Reverse cycle
- Configuration
- β
- Air distribution
- Ducted or non-ducted
- Indoor unit
- β
- Rated cooling capacity (35 Β°C)
- 7.10 kW
- Cooling power input
- β
- Rated heating capacity (7 Β°C)
- 7.10 kW
- Heating power input
- β
- EER, full load (tested)
- 4.26
- COP, full load (tested)
- 4.65
- Rated AEER
- 4.09
- Rated ACOP
- 4.45
- Standby power (PIA)
- 19.0 W
- Compressor
- Variable speed, Inverter
- Refrigerant
- R32
- Power supply
- Single phase
- Indoor sound power
- β
- Outdoor sound power
- 67 dB(A)
- Demand response (AS/NZS 4755)
- Yes
- Country of manufacture
- China
Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.
Haier 4U71S2PR1FA zoned energy rating figures
As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.
| Zone | Profile | Cooling stars | Heating stars | Cooling kWh | Heating kWh |
|---|---|---|---|---|---|
| Coldcommercial | commercial | β | β | 563 | 767 |
| Coldresidential | residential | 3.0 | 2.5 | 359 | 2,275 |
| Mixedcommercial | commercial | β | β | 782 | 422 |
| Mixedresidential | residential | 3.0 | 3.0 | 550 | 895 |
| Hotcommercial | commercial | β | β | 1,785 | 116 |
| Hotresidential | residential | 4.5 | 3.0 | 1,468 | 170 |
Part-load test points (18 values)
- h__h2_ext_cap_power_rated
- 2270 W
- c__t1_half_cap_power_rated
- 680 W
- c__t1_have_min_cap_results
- No
- h__h1_half_cap_power_rated
- 685 W
- h__h1_have_min_cap_results
- No
- h__h3_have_ext_cap_results
- No
- h__h2_have_full_cap_results
- No
- h__h2_have_half_cap_results
- No
- h__h3_have_full_cap_results
- No
- h__h3_have_half_cap_results
- No
- h__h2_ext_cap_heat_cap_rated
- 7100 W
- h__h1_half_cap_heat_cap_rated
- 3600 W
- h__h2_is_capable_extended_load
- Yes
- c__low_temp_half_cap_power_rated
- 500 W
- c__low_temp_have_min_cap_results
- No
- c__t1_half_cap_cooling_cap_rated
- 3600 W
- c__low_temp_have_half_cap_results
- Yes
- c__low_temp_half_cap_cooling_cap_rated
- 3850 W
Australian GEMS registration details
- Registration number
- AAC9389
- GEMS registration id
- β
- Status
- approved
- Registration expires
- 7 September 2030
- Registered for sale in
- Australia, New Zealand
- Family
- β
- Regulatory standard
- Greenhouse and Energy Minimum Standards (Air Conditioners up to 65kW) Determination 2019
- Test standard
- AS/NZS 3823.1.4:2012
- MEPS
- 2019
- Product class
- 19
Source: Australian Government Energy Rating (GEMS) registration data, DCCEEW via data.gov.au (CC BY 3.0 AU). Dataset published 28 October 2026; last checked 29 October 2026. Manufacturer: haier.com.au/air-conditioning. How the derived figures are calculated.