c/kWh
Energy rating (cooling)
3
Heating: 2.5
Annual electricity use
1,595 kWh
632 cooling + 963 heating
Estimated running cost
$510 / year
$43 / month Β· $5,104 over 10 years
Capacity
7 kW cooling
7 kW heating

About the same electricity as the median of 211 comparable 7 kW reverse cycle split system registrations (1,600 kWh a year) in the mixed zone. Uses less than 51% of them.

Across all 3,680 air conditioner registrations sold in Australia, it uses less than 61% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the mixed zone (Richmond NSW climate: Sydney, Melbourne, Adelaide, Perth). Mixed climate zone shown by default (Sydney, Melbourne, Adelaide, Perth); switch to cold or hot. Cost = kWh Γ— 32c/kWh in AUD; change the price above to your tariff.

TECO TWS-TSO72H3DVJT running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 3,069$982$9,821
Mixed zone 1,595$510$5,104
Hot zone 1,982$634$6,342

At 32c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Air conditioners that use less electricity

Same configuration and type, cooling capacity within 12% of 7 kW, at least 3% lower annual kWh in the mixed zone.

ModelStarsEst. cost / yrCompare
Solar Acdc DGWA5-ACDCBLW-24KR27 kW heating6.5 kW cooling1,281 kWh/yr4.5$410
Mitsubishi Heavy Industries SRC63ZRA-W / SRK63ZRA-WF17.1 kW heating6.3 kW cooling1,308 kWh/yr3.5$419
Mitsubishi Heavy Industries SRK63/DXK21ZRA-WF17.1 kW heating6.3 kW cooling1,308 kWh/yr3.5$419
Pioneer International HPR-24A27 kW heating6.7 kW cooling1,373 kWh/yr4.5$439
Panasonic U-71PZ4R5 / S-6071PT3E6.8 kW heating6.8 kW cooling1,399 kWh/yr3$448

Air conditioners similar to the TECO TWS-TSO72H3DVJT

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
Carrier 38QRF070N8/42QRF070N87.5 kW heating7 kW cooling1,510 kWh/yr3.5$483
Rinnai HONRTX70/HINRTX707.5 kW heating7 kW cooling1,510 kWh/yr3.5$483
Samsung Electronics AR40H24C1AMX / AR40H24C1AMN7.4 kW heating7 kW cooling1,509 kWh/yr3.5$483
Comfee CASG-XG70B/CASN-XG70B7.5 kW heating7 kW cooling1,510 kWh/yr3.5$483
Midea MFAG70VB-W/MFAG70VB-N7.5 kW heating7 kW cooling1,510 kWh/yr3.5$483
Carrier 38QAF070N8/42QAF070N87.5 kW heating7 kW cooling1,510 kWh/yr3.5$483
Hitachi RAC-VJ70PHAT/RAK-VJ70PHAT8 kW heating7 kW cooling1,453 kWh/yr4$465
Kaden KSI-7.07.5 kW heating7 kW cooling1,510 kWh/yr3.5$483

Compare TWS-TSO72H3DVJT with another model

TECO TWS-TSO72H3DVJT specifications

Type
Reverse cycle
Configuration
Split system
Air distribution
Non-ducted
Indoor unit
Wall hung
Rated cooling capacity (35 Β°C)
7.00 kW
Cooling power input
2.01 kW
Rated heating capacity (7 Β°C)
7.00 kW
Heating power input
2.09 kW
EER, full load (tested)
3.41
COP, full load (tested)
3.30
Rated AEER
3.45
Rated ACOP
3.32
Standby power (PIA)
4.8 W
Compressor
Variable speed, Inverter
Refrigerant
R32
Power supply
Single phase
Indoor sound power
52.7 dB(A)
Outdoor sound power
63.9 dB(A)
Demand response (AS/NZS 4755)
Yes
Country of manufacture
China

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

TECO TWS-TSO72H3DVJT zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––787822
Coldresidential3.01.54022,667
Mixedcommercial––1,041418
Mixedresidential3.02.5632963
Hotcommercial––2,39288
Hotresidential3.03.01,845137
Part-load test points (18 values)
c__t1_half_cap_power_rated
740 W
c__t1_have_min_cap_results
No
h__h1_half_cap_power_rated
680 W
h__h1_have_min_cap_results
No
h__h2_full_cap_power_rated
2300 W
h__h2_have_half_cap_results
No
h__h3_have_full_cap_results
No
h__h3_have_half_cap_results
No
h__h1_half_cap_heat_cap_rated
3500 W
h__h2_full_cap_heat_cap_rated
6000 W
h__h2_is_capable_extended_load
No
c__low_temp_full_cap_power_rated
1837.14 W
c__low_temp_half_cap_power_rated
600 W
c__low_temp_have_min_cap_results
No
c__t1_half_cap_cooling_cap_rated
3400 W
c__low_temp_have_half_cap_results
Yes
c__low_temp_full_cap_cooling_cap_rated
7539 W
c__low_temp_half_cap_cooling_cap_rated
3500 W

Australian GEMS registration details

Registration number
AAC7278
GEMS registration id
152610
Status
approved, available (self-reported)
Registration expires
26 February 2028
Registered for sale in
Australia, Fiji, New Zealand
Family
–
Regulatory standard
[SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
Test standard
AS/NZS 3823.1.1:2012
MEPS
2019
Product class
Class 9

Source: Australian Government Energy Rating (GEMS) registration data, DCCEEW via data.gov.au (CC BY 3.0 AU). Dataset published 25 September 2026; last checked 26 September 2026. Manufacturer: teco.com.au. How the derived figures are calculated.