Australia Β· costs in AUD

Reverse cycle split system air conditioner, wall hung
Westinghouse WSD27HWA-E/WSD27HWA-I Air Conditioner
Westinghouse WSD27HWA-E/WSD27HWA-I is a 2.6 kW reverse cycle split system air conditioner registered under Australiaβs Energy Rating (GEMS) scheme (registration AAC7557).
- Energy rating (cooling)
- 6
- Heating: 3
- Annual electricity use
- 528 kWh
- 142 cooling + 386 heating
- Estimated running cost
- $169 / year
- $14 / month Β· $1,690 over 10 years
- Capacity
- 2.6 kW cooling
- 3.5 kW heating
3% less electricity than the median of 191 comparable 2.5 kW reverse cycle split system registrations (543 kWh a year) in the mixed zone. Uses less than 56% of them.
Across all 3,680 air conditioner registrations sold in Australia, it uses less than 93% (this compares very different sizes, so the cohort figure above is the useful one).
Annual kWh is the government label figure for a residential user in the mixed zone (Richmond NSW climate: Sydney, Melbourne, Adelaide, Perth). Mixed climate zone shown by default (Sydney, Melbourne, Adelaide, Perth); switch to cold or hot. Cost = kWh Γ 32c/kWh in AUD; change the price above to your tariff.
Westinghouse WSD27HWA-E running cost by climate zone
| Climate zone | kWh / year | Per year | 10 years |
|---|---|---|---|
| Cold zone | 1,093 | $350 | $3,498 |
| Mixed zone | 528 | $169 | $1,690 |
| Hot zone | 463 | $148 | $1,482 |
At 32c/kWh. Formula: cost = annual kWh Γ price. The kWh figure is the labelβs residential estimate for that zone; commercial-profile figures are in the specifications.
Air conditioners that use less electricity
Same configuration and type, cooling capacity within 12% of 2.6 kW, at least 3% lower annual kWh in the mixed zone.
| Model | Stars | Est. cost / yr | Compare |
|---|---|---|---|
| Midea MFEP26VB-W/MFEP26VB-N2.7 kW heating2.6 kW cooling404 kWh/yr | 6.5 | $129 | |
| Actron Air WRC-026DS / WRE-026DS2.7 kW heating2.6 kW cooling404 kWh/yr | 6.5 | $129 | |
| Midea MFEP26VA-W/MFEP26VA-N2.7 kW heating2.6 kW cooling405 kWh/yr | 6.5 | $130 | |
| Actron Air WRC-026CS / WRE-026CS2.8 kW heating2.6 kW cooling410 kWh/yr | 6.5 | $131 | |
| Rinnai HONRJX25/HINRJX252.7 kW heating2.6 kW cooling416 kWh/yr | 7 | $133 |
Air conditioners similar to the Westinghouse WSD27HWA-E
Technically comparable registrations: same configuration and type, capacity within 12%.
| Model | Stars | Est. cost / yr | Compare |
|---|---|---|---|
| Actron Air WRC-026CS / WRE-026CS2.8 kW heating2.6 kW cooling410 kWh/yr | 6.5 | $131 | |
| Rinnai HONRJX25/HINRJX252.7 kW heating2.6 kW cooling416 kWh/yr | 7 | $133 | |
| Aux ASW-H27A4/CAR3DI2.7 kW heating2.6 kW cooling424 kWh/yr | 7 | $136 | |
| Carrier 38QHG026N8/42QHG026N8-12.8 kW heating2.6 kW cooling427 kWh/yr | 6 | $137 | |
| Rinnai HSNRP26B2.7 kW heating2.6 kW cooling424 kWh/yr | 5.5 | $136 | |
| Midea MFXP26W/MFXP26N2.7 kW heating2.6 kW cooling424 kWh/yr | 5.5 | $136 | |
| Midea MFAB-26WC/MFAB-26NC2.7 kW heating2.6 kW cooling424 kWh/yr | 5.5 | $136 | |
| Smart Lifestyle Australia SLA-26-CHSD2.7 kW heating2.6 kW cooling419 kWh/yr | 6 | $134 |
Compare WSD27HWA-E/WSD27HWA-I with another model
Westinghouse WSD27HWA-E specifications
- Type
- Reverse cycle
- Configuration
- Split system
- Air distribution
- Non-ducted
- Indoor unit
- Wall hung
- Rated cooling capacity (35 Β°C)
- 2.65 kW
- Cooling power input
- 0.49 kW
- Rated heating capacity (7 Β°C)
- 3.45 kW
- Heating power input
- 0.74 kW
- EER, full load (tested)
- 5.31
- COP, full load (tested)
- 4.93
- Rated AEER
- 5.37
- Rated ACOP
- 4.66
- Standby power (PIA)
- 1.2 W
- Compressor
- Variable speed, Inverter
- Refrigerant
- R32
- Power supply
- Single phase
- Indoor sound power
- 54.4 dB(A)
- Outdoor sound power
- 56.2 dB(A)
- Demand response (AS/NZS 4755)
- Yes
- Country of manufacture
- China
Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.
Westinghouse WSD27HWA-E zoned energy rating figures
As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.
| Zone | Profile | Cooling stars | Heating stars | Cooling kWh | Heating kWh |
|---|---|---|---|---|---|
| Coldcommercial | commercial | β | β | 102 | 325 |
| Coldresidential | residential | 6.5 | 3.0 | 90 | 1,003 |
| Mixedcommercial | commercial | β | β | 180 | 174 |
| Mixedresidential | residential | 6.0 | 3.0 | 142 | 386 |
| Hotcommercial | commercial | β | β | 456 | 36 |
| Hotresidential | residential | 7.0 | 3.5 | 406 | 57 |
Part-load test points (23 values)
- c__t1_min_cap_power_rated
- 174 W
- h__h1_min_cap_power_rated
- 215 W
- h__h2_ext_cap_power_rated
- 1231 W
- c__t1_half_cap_power_rated
- 226 W
- c__t1_have_min_cap_results
- Yes
- h__h1_half_cap_power_rated
- 296 W
- h__h1_have_min_cap_results
- Yes
- h__h3_have_ext_cap_results
- No
- h__h2_have_full_cap_results
- No
- h__h2_have_half_cap_results
- No
- h__h3_have_full_cap_results
- No
- h__h3_have_half_cap_results
- No
- h__h1_min_cap_heat_cap_rated
- 1179 W
- h__h2_ext_cap_heat_cap_rated
- 3890 W
- h__h1_half_cap_heat_cap_rated
- 1684 W
- h__h2_is_capable_extended_load
- Yes
- c__low_temp_min_cap_power_rated
- 108 W
- c__t1_min_cap_cooling_cap_rated
- 1050 W
- c__low_temp_half_cap_power_rated
- 145 W
- c__t1_half_cap_cooling_cap_rated
- 1277 W
- c__low_temp_have_half_cap_results
- Yes
- c__low_temp_min_cap_cooling_cap_rated
- 1003 W
- c__low_temp_half_cap_cooling_cap_rated
- 1322 W
Other model numbers on registration AAC7557
Registered together and sharing the same test results. Usually variants of the same unit.
Australian GEMS registration details
- Registration number
- AAC7557
- GEMS registration id
- 154712
- Status
- approved, available (self-reported)
- Registration expires
- 7 June 2028
- Registered for sale in
- Australia, New Zealand
- Family
- WSD27HWA-E/WSD27HWA-I
- Regulatory standard
- [SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
- Test standard
- AS/NZS 3823.1.1:2012
- MEPS
- 2019
- Product class
- Class 8