c/kWh
Energy rating (cooling)
2.5
Heating: 0
Annual electricity use
13,753 kWh
1,080 cooling + 12,673 heating
Estimated running cost
$4,538 / year
$378 / month Β· $45,385 over 10 years
Capacity
17 kW cooling
18.2 kW heating

64% more electricity than the median of 51 comparable 18 kW reverse cycle ducted split system registrations (8,396 kWh a year) in the cold zone. Uses less than 0% of them.

Across all 3,612 air conditioner registrations sold in Australia, it uses less than 9% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ— 33c/kWh in NZD; change the price above to your tariff.

Actron Air CRV17AT running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 13,753$4,538$45,385
Mixed zone 6,493$2,143$21,427
Hot zone 5,370$1,772$17,721

At 33c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Heat pumps that use less electricity

Same configuration and type, cooling capacity within 12% of 17 kW, at least 3% lower annual kWh in the cold zone.

ModelStarsEst. cost / yrCompare
Daikin RZA160CV1 / FDYAN160AV118 kW heating15.5 kW cooling4,493 kWh/yr2$1,483
Carrier 38QSH170D8S / 42QSH170D8S17 kW heating17 kW cooling6,907 kWh/yr3.5$2,279
Midea DUCMI170IHB/UCMI170OB17.5 kW heating17 kW cooling7,066 kWh/yr4$2,332
Midea DUCMI170IHB/UCMI170OB17.5 kW heating17 kW cooling7,066 kWh/yr4$2,332
Actron Air LRC-170CS / LRE-170CS17.6 kW heating16.6 kW cooling7,156 kWh/yr4$2,361

Heat pumps similar to the Actron Air CRV17AT

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
Midea DUCMI170IHB/UCMI170OB17.5 kW heating17 kW cooling7,066 kWh/yr4$2,332
Carrier 38QSV170N8/42QSV170N8S18 kW heating17 kW cooling7,212 kWh/yr3.5$2,380
Kaden KDI60 / KDI6018 kW heating17 kW cooling7,317 kWh/yr4$2,415
Carrier 38QSH170D8S / 42QSH170D8S17 kW heating17 kW cooling6,907 kWh/yr3.5$2,279
Kaden KDI-17.018 kW heating17 kW cooling7,212 kWh/yr3.5$2,380
Rinnai DSNSR18B1TA18 kW heating17 kW cooling7,212 kWh/yr3.5$2,380
Midea DUCMI170IHB/UCMI170OB17.5 kW heating17 kW cooling7,066 kWh/yr4$2,332
Rinnai DONSR18B1TA/DINLR18B1SA18 kW heating17 kW cooling7,212 kWh/yr3.5$2,380

Compare CRV17AT / EVV17AS with another model

Actron Air CRV17AT specifications

Type
Reverse cycle
Configuration
Split system
Air distribution
Ducted
Indoor unit
–
Rated cooling capacity (35 Β°C)
17.00 kW
Cooling power input
5.00 kW
Rated heating capacity (7 Β°C)
18.20 kW
Heating power input
5.17 kW
EER, full load (tested)
3.32
COP, full load (tested)
3.40
Rated AEER
3.36
Rated ACOP
3.48
Standby power (PIA)
19.0 W
Compressor
Variable speed, Inverter
Refrigerant
R32
Power supply
Three phase
Indoor sound power
–
Outdoor sound power
–
Demand response (AS/NZS 4755)
Yes
Country of manufacture
Australia

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

Actron Air CRV17AT zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––2,3413,490
Coldresidential2.50.01,08012,673
Mixedcommercial––2,9431,647
Mixedresidential2.50.51,6824,811
Hotcommercial––6,538286
Hotresidential3.01.54,880490
Part-load test points (20 values)
h__h2_ext_cap_power_rated
3295 W
c__t1_half_cap_power_rated
1812 W
c__t1_have_min_cap_results
No
h__h1_half_cap_power_rated
1952 W
h__h1_have_min_cap_results
No
h__h3_have_ext_cap_results
No
h__h2_have_full_cap_results
No
h__h2_have_half_cap_results
No
h__h3_have_full_cap_results
No
h__h3_have_half_cap_results
No
h__h2_ext_cap_heat_cap_rated
8582 W
h__h1_half_cap_heat_cap_rated
8663 W
h__h2_is_capable_extended_load
Yes
c__low_temp_full_cap_power_rated
4570 W
c__low_temp_half_cap_power_rated
1656.1680000000001 W
c__low_temp_have_min_cap_results
No
c__t1_half_cap_cooling_cap_rated
8282 W
c__low_temp_have_half_cap_results
No
c__low_temp_full_cap_cooling_cap_rated
18309 W
c__low_temp_half_cap_cooling_cap_rated
8919.714 W

Other model numbers on registration AAC7978

Registered together and sharing the same test results. Usually variants of the same unit.

New Zealand E3 registration details

Registration number
AAC7978
GEMS registration id
148704
Status
approved, available (self-reported)
Registration expires
19 December 2028
Registered for sale in
Australia, New Zealand
Family
CRV17AT / EVV17AS - EXV SE
Regulatory standard
[SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
Test standard
AS/NZS 3823.1.2:2012
MEPS
2019
Product class
Class 11

Source: E3 programme registration data (EECA, New Zealand) (trans-Tasman E3 registration data published by DCCEEW on data.gov.au, CC BY 3.0 AU). Dataset published 25 September 2026; last checked 26 September 2026. Manufacturer: actronair.com.au. How the derived figures are calculated.