c/kWh
Energy rating (cooling)
3
Heating: 2
Annual electricity use
11,248 kWh
1,517 cooling + 9,731 heating
Estimated running cost
$3,712 / year
$309 / month Β· $37,118 over 10 years
Capacity
25 kW cooling
26 kW heating

14% less electricity than the median of 15 comparable 25 kW reverse cycle ducted split system registrations (13,045 kWh a year) in the cold zone. Uses less than 87% of them.

Across all 3,612 air conditioner registrations sold in Australia, it uses less than 12% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ— 33c/kWh in NZD; change the price above to your tariff.

Actron Air CRV25BT running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 11,248$3,712$37,118
Mixed zone 5,912$1,951$19,510
Hot zone 7,453$2,459$24,595

At 33c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Heat pumps that use less electricity

Same configuration and type, cooling capacity within 12% of 25 kW, at least 3% lower annual kWh in the cold zone.

ModelStarsEst. cost / yrCompare
Actron Air CRV22BT / EAA22BS & EFV22BS23 kW heating22 kW cooling9,879 kWh/yr3$3,260
Actron Air CRV22BT / EVV22BS23 kW heating22 kW cooling9,879 kWh/yr3$3,260

Heat pumps similar to the Actron Air CRV25BT

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
Fujitsu AOTA90LALT/ARTC90LATU28 kW heating25 kW cooling14,958 kWh/yr1.5$4,936
Mitsubishi Electric PUZ-ZM250YKA-A / PEA-M250LAA28 kW heating24.5 kW cooling12,437 kWh/yr2.5$4,104
Daikin RZYQ10TY1 / FDYQ250LCV126.8 kW heating24 kW cooling13,045 kWh/yr2$4,305
Braemar SCHV24D3S/SDHV24D1S26 kW heating24 kW cooling13,685 kWh/yr1.5$4,516
Toshiba RAV-GM2801AT8-A/RAV-RM2801DTP-E227 kW heating24 kW cooling12,847 kWh/yr1.5$4,240
Mitsubishi Heavy Industries FDCA250VSA-W/FDUA250VH28 kW heating23.5 kW cooling13,265 kWh/yr2.5$4,377
APAC S024OVR3SA / S024IVR3SA-TR20.4 kW heating23.4 kW cooling11,785 kWh/yr1$3,889

Other Actron Air models of similar capacity

ModelStarsEst. cost / yrCompare
Actron Air SCA260C/SCG260E25.3 kW heating24.7 kW cooling14,019 kWh/yr1.5$4,626

Compare CRV25BT / EVV25BS with another model

Actron Air CRV25BT specifications

Type
Reverse cycle
Configuration
Split system
Air distribution
Ducted
Indoor unit
–
Rated cooling capacity (35 Β°C)
25.00 kW
Cooling power input
7.27 kW
Rated heating capacity (7 Β°C)
26.00 kW
Heating power input
6.84 kW
EER, full load (tested)
3.43
COP, full load (tested)
3.78
Rated AEER
3.42
Rated ACOP
3.78
Standby power (PIA)
14.0 W
Compressor
Variable speed, Inverter
Refrigerant
R32
Power supply
Three phase
Indoor sound power
–
Outdoor sound power
–
Demand response (AS/NZS 4755)
Yes
Country of manufacture
Australia

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

Actron Air CRV25BT zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––2,8853,059
Coldresidential3.02.01,5179,731
Mixedcommercial––3,8781,568
Mixedresidential2.52.52,3693,543
Hotcommercial––8,919329
Hotresidential3.03.06,937516
Part-load test points (18 values)
h__h2_ext_cap_power_rated
6938 W
c__t1_half_cap_power_rated
3054 W
c__t1_have_min_cap_results
No
h__h1_half_cap_power_rated
2527 W
h__h1_have_min_cap_results
No
h__h3_have_ext_cap_results
No
h__h2_have_full_cap_results
No
h__h2_have_half_cap_results
No
h__h3_have_full_cap_results
No
h__h3_have_half_cap_results
No
h__h2_ext_cap_heat_cap_rated
20850 W
h__h1_half_cap_heat_cap_rated
12415 W
h__h2_is_capable_extended_load
Yes
c__low_temp_half_cap_power_rated
2377 W
c__low_temp_have_min_cap_results
No
c__t1_half_cap_cooling_cap_rated
12365 W
c__low_temp_have_half_cap_results
Yes
c__low_temp_half_cap_cooling_cap_rated
12517 W

Other model numbers on registration AAC8793

Registered together and sharing the same test results. Usually variants of the same unit.

New Zealand E3 registration details

Registration number
AAC8793
GEMS registration id
167620
Status
approved, available (self-reported)
Registration expires
15 April 2030
Registered for sale in
Australia, New Zealand
Family
CRV25BT / EVV25BS
Regulatory standard
[SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
Test standard
AS/NZS 3823.1.2:2012
MEPS
2019
Product class
Class 11