New Zealand Β· costs in NZD

Reverse cycle split system air conditioner, wall hung
Actron Air HRC-026DS / HRE-026DS Heat Pump
Actron Air HRC-026DS / HRE-026DS is a 2.5 kW reverse cycle split system heat pump registered for sale in New Zealand under the trans-Tasman E3 energy rating scheme (registration AAC10307).
- Energy rating (cooling)
- 5.5
- Heating: 3
- Annual electricity use
- 919 kWh
- 99 cooling + 820 heating
- Estimated running cost
- $303 / year
- $25 / month Β· $3,033 over 10 years
- Capacity
- 2.5 kW cooling
- 2.9 kW heating
14% less electricity than the median of 177 comparable 2.5 kW reverse cycle split system registrations (1,073 kWh a year) in the cold zone. Uses less than 82% of them.
Across all 3,611 air conditioner registrations sold in Australia, it uses less than 90% (this compares very different sizes, so the cohort figure above is the useful one).
Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ 33c/kWh in NZD; change the price above to your tariff.
Actron Air HRC-026DS running cost by climate zone
| Climate zone | kWh / year | Per year | 10 years |
|---|---|---|---|
| Cold zone | 919 | $303 | $3,033 |
| Mixed zone | 470 | $155 | $1,551 |
| Hot zone | 505 | $167 | $1,667 |
At 33c/kWh. Formula: cost = annual kWh Γ price. The kWh figure is the labelβs residential estimate for that zone; commercial-profile figures are in the specifications.
Heat pumps that use less electricity
Same configuration and type, cooling capacity within 12% of 2.5 kW, at least 3% lower annual kWh in the cold zone.
| Model | Stars | Est. cost / yr | Compare |
|---|---|---|---|
| Hitachi RAC-VJ25NHAE/RAI-VJ25RHAE3.5 kW heating2.5 kW cooling653 kWh/yr | 4 | $215 | |
| Midea MFEP26VA-W/MFEP26VA-N2.7 kW heating2.6 kW cooling776 kWh/yr | 6.5 | $256 | |
| Midea MFEP26VB-W/MFEP26VB-N2.7 kW heating2.6 kW cooling790 kWh/yr | 7 | $261 | |
| Actron Air WRC-026DS / WRE-026DS2.7 kW heating2.6 kW cooling790 kWh/yr | 7 | $261 | |
| Actron Air WRC-026CS / WRE-026CS2.8 kW heating2.6 kW cooling804 kWh/yr | 7 | $265 |
Heat pumps similar to the Actron Air HRC-026DS
Technically comparable registrations: same configuration and type, capacity within 12%.
| Model | Stars | Est. cost / yr | Compare |
|---|---|---|---|
| Midea MFEF26VA-W/MFEF26VA-N2.9 kW heating2.5 kW cooling919 kWh/yr | 5.5 | $303 | |
| Carrier 38QRF026N8/42QRF026N82.8 kW heating2.5 kW cooling897 kWh/yr | 5 | $296 | |
| Daikin RXM25AVMA / FTXM25AVMA3.2 kW heating2.5 kW cooling888 kWh/yr | 6 | $293 | |
| Rinnai HSNRTX252.8 kW heating2.5 kW cooling897 kWh/yr | 5 | $296 | |
| Carrier 38QAF026N8/42QAF026N82.8 kW heating2.5 kW cooling897 kWh/yr | 5 | $296 | |
| Midea MFAG26VB-W/MFAG26VB-N2.8 kW heating2.5 kW cooling897 kWh/yr | 5 | $296 | |
| Rinnai HONRTX25/HINRTX252.8 kW heating2.5 kW cooling897 kWh/yr | 5 | $296 | |
| Pioneer International HPR-09A22.6 kW heating2.5 kW cooling845 kWh/yr | 4 | $279 |
Compare HRC-026DS / HRE-026DS with another model
Actron Air HRC-026DS specifications
- Type
- Reverse cycle
- Configuration
- Split system
- Air distribution
- Non-ducted
- Indoor unit
- Wall hung
- Rated cooling capacity (35 Β°C)
- 2.53 kW
- Cooling power input
- 0.55 kW
- Rated heating capacity (7 Β°C)
- 2.91 kW
- Heating power input
- 0.58 kW
- EER, full load (tested)
- 4.59
- COP, full load (tested)
- 5.01
- Rated AEER
- 4.62
- Rated ACOP
- 5.01
- Standby power (PIA)
- 0.4 W
- Compressor
- Variable speed, Inverter
- Refrigerant
- R32
- Power supply
- Single phase
- Indoor sound power
- 52.7 dB(A)
- Outdoor sound power
- 59.1 dB(A)
- Demand response (AS/NZS 4755)
- Yes
- Country of manufacture
- China
Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.
Actron Air HRC-026DS zoned energy rating figures
As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.
| Zone | Profile | Cooling stars | Heating stars | Cooling kWh | Heating kWh |
|---|---|---|---|---|---|
| Coldcommercial | commercial | β | β | 158 | 266 |
| Coldresidential | residential | 5.5 | 3.0 | 99 | 820 |
| Mixedcommercial | commercial | β | β | 231 | 140 |
| Mixedresidential | residential | 5.0 | 3.5 | 158 | 312 |
| Hotcommercial | commercial | β | β | 555 | 29 |
| Hotresidential | residential | 5.5 | 4.0 | 460 | 45 |
Part-load test points (23 values)
- c__t1_min_cap_power_rated
- 165 W
- h__h1_min_cap_power_rated
- 187 W
- h__h2_ext_cap_power_rated
- 930 W
- c__t1_half_cap_power_rated
- 245 W
- c__t1_have_min_cap_results
- Yes
- h__h1_half_cap_power_rated
- 250 W
- h__h1_have_min_cap_results
- Yes
- h__h3_have_ext_cap_results
- No
- h__h2_have_full_cap_results
- No
- h__h2_have_half_cap_results
- No
- h__h3_have_full_cap_results
- No
- h__h3_have_half_cap_results
- No
- h__h1_min_cap_heat_cap_rated
- 1070 W
- h__h2_ext_cap_heat_cap_rated
- 3100 W
- h__h1_half_cap_heat_cap_rated
- 1445 W
- h__h2_is_capable_extended_load
- Yes
- c__low_temp_min_cap_power_rated
- 120 W
- c__t1_min_cap_cooling_cap_rated
- 780 W
- c__low_temp_half_cap_power_rated
- 170 W
- c__t1_half_cap_cooling_cap_rated
- 1220 W
- c__low_temp_have_half_cap_results
- Yes
- c__low_temp_min_cap_cooling_cap_rated
- 930 W
- c__low_temp_half_cap_cooling_cap_rated
- 1350 W
New Zealand E3 registration details
- Registration number
- AAC10307
- GEMS registration id
- 180777
- Status
- approved, available (self-reported)
- Registration expires
- 20 July 2031
- Registered for sale in
- Australia, New Zealand
- Family
- β
- Regulatory standard
- [SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
- Test standard
- AS/NZS 3823.1.1:2012
- MEPS
- 2019
- Product class
- Class 8
Source: E3 programme registration data (EECA, New Zealand) (trans-Tasman E3 registration data published by DCCEEW on data.gov.au, CC BY 3.0 AU). Dataset published 25 September 2026; last checked 26 September 2026. Manufacturer: actronair.com.au. How the derived figures are calculated.