c/kWh
Energy rating (cooling)
4.5
Heating: 2
Annual electricity use
4,311 kWh
446 cooling + 3,865 heating
Estimated running cost
$1,423 / year
$119 / month Β· $14,226 over 10 years
Capacity
10.5 kW cooling
11.5 kW heating

9% less electricity than the median of 136 comparable 10 kW reverse cycle ducted split system registrations (4,758 kWh a year) in the cold zone. Uses less than 82% of them.

Across all 3,611 air conditioner registrations sold in Australia, it uses less than 45% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ— 33c/kWh in NZD; change the price above to your tariff.

Actron Air LRC-100CS running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 4,311$1,423$14,226
Mixed zone 2,126$702$7,016
Hot zone 2,072$684$6,838

At 33c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Heat pumps that use less electricity

Same configuration and type, cooling capacity within 12% of 10.5 kW, at least 3% lower annual kWh in the cold zone.

ModelStarsEst. cost / yrCompare
Panasonic U-100PZ3R8 / S-1014PF3E9.5 kW heating9.5 kW cooling3,634 kWh/yr3$1,199
Panasonic U-100PZ3R5 / S-1014PF3E9.5 kW heating9.5 kW cooling3,634 kWh/yr3$1,199
Brivis AONSR13B1/AINHU11B111.3 kW heating10.3 kW cooling3,713 kWh/yr5$1,225

Heat pumps similar to the Actron Air LRC-100CS

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
Midea UCMI90OB/DUCMI90IB11 kW heating10.5 kW cooling4,207 kWh/yr4.5$1,388
Kaden KDI36 / KDI3611.5 kW heating10.5 kW cooling4,427 kWh/yr4.5$1,461
Mdv C-UV-105N8-QC3W / CDV-105HN8-QC3W11 kW heating10.5 kW cooling4,244 kWh/yr4.5$1,401
Aurora AU-BS36HR-2A-O / AU-LCF36-2A-I11.5 kW heating10.5 kW cooling4,349 kWh/yr4.5$1,435
Midea DUCMI105IHB/UCMI105OB11 kW heating10.5 kW cooling4,207 kWh/yr4.5$1,388
Rinnai DONSR11B1/DINLR11B111.5 kW heating10.5 kW cooling4,403 kWh/yr4.5$1,453
Rinnai DONSR11B1/DINLR11B111.5 kW heating10.5 kW cooling4,404 kWh/yr4.5$1,453
Mdv C-UV-105N8-QC3W / CDV-105A6N8-QC3W11 kW heating10.5 kW cooling4,253 kWh/yr4.5$1,403

Compare LRC-100CS / LRE-100CS with another model

Actron Air LRC-100CS specifications

Type
Reverse cycle
Configuration
Split system
Air distribution
Ducted
Indoor unit
–
Rated cooling capacity (35 Β°C)
10.50 kW
Cooling power input
3.09 kW
Rated heating capacity (7 Β°C)
11.50 kW
Heating power input
2.70 kW
EER, full load (tested)
3.31
COP, full load (tested)
4.18
Rated AEER
3.36
Rated ACOP
4.21
Standby power (PIA)
10.0 W
Compressor
Variable speed, Inverter
Refrigerant
R32
Power supply
Single phase
Indoor sound power
–
Outdoor sound power
–
Demand response (AS/NZS 4755)
Yes
Country of manufacture
China

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

Actron Air LRC-100CS zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––3561,199
Coldresidential4.52.04463,865
Mixedcommercial––933612
Mixedresidential4.03.07171,409
Hotcommercial––-134135
Hotresidential5.53.51,861211
Part-load test points (20 values)
c__t1_min_cap_power_rated
731 W
h__h1_min_cap_power_rated
481 W
h__h2_ext_cap_power_rated
3485 W
c__t1_half_cap_power_rated
1838 W
c__t1_have_min_cap_results
Yes
h__h1_half_cap_power_rated
1126 W
h__h1_have_min_cap_results
Yes
h__h1_min_cap_heat_cap_rated
2570 W
h__h2_ext_cap_heat_cap_rated
10230 W
h__h1_half_cap_heat_cap_rated
5830 W
h__h2_is_capable_extended_load
Yes
c__low_temp_min_cap_power_rated
354 W
c__t1_min_cap_cooling_cap_rated
3110 W
c__low_temp_full_cap_power_rated
2824.26 W
c__low_temp_half_cap_power_rated
819 W
c__t1_half_cap_cooling_cap_rated
5570 W
c__low_temp_have_half_cap_results
Yes
c__low_temp_min_cap_cooling_cap_rated
2660 W
c__low_temp_full_cap_cooling_cap_rated
11308.5 W
c__low_temp_half_cap_cooling_cap_rated
5380 W

New Zealand E3 registration details

Registration number
AAC6916
GEMS registration id
146387
Status
approved, available (self-reported)
Registration expires
30 August 2027
Registered for sale in
Australia, New Zealand
Family
–
Regulatory standard
[SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
Test standard
AS/NZS 3823.1.2:2012
MEPS
2019
Product class
Class 11

Source: E3 programme registration data (EECA, New Zealand) (trans-Tasman E3 registration data published by DCCEEW on data.gov.au, CC BY 3.0 AU). Dataset published 25 September 2026; last checked 26 September 2026. Manufacturer: actronair.com.au. How the derived figures are calculated.