c/kWh
Energy rating (cooling)
4.5
Heating: 2
Annual electricity use
4,244 kWh
438 cooling + 3,806 heating
Estimated running cost
$1,401 / year
$117 / month Β· $14,005 over 10 years
Capacity
10.5 kW cooling
11 kW heating

11% less electricity than the median of 136 comparable 10 kW reverse cycle ducted split system registrations (4,758 kWh a year) in the cold zone. Uses less than 87% of them.

Across all 3,611 air conditioner registrations sold in Australia, it uses less than 46% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ— 33c/kWh in NZD; change the price above to your tariff.

Mdv running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 4,244$1,401$14,005
Mixed zone 2,126$702$7,016
Hot zone 2,031$670$6,702

At 33c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Heat pumps that use less electricity

Same configuration and type, cooling capacity within 12% of 10.5 kW, at least 3% lower annual kWh in the cold zone.

ModelStarsEst. cost / yrCompare
Panasonic U-100PZ3R8 / S-1014PF3E9.5 kW heating9.5 kW cooling3,634 kWh/yr3$1,199
Panasonic U-100PZ3R5 / S-1014PF3E9.5 kW heating9.5 kW cooling3,634 kWh/yr3$1,199
Brivis AONSR13B1/AINHU11B111.3 kW heating10.3 kW cooling3,713 kWh/yr5$1,225

Heat pumps similar to the Mdv

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
Aurora AU-BS36HR-2A-O / AU-LCF36-2A-I11.5 kW heating10.5 kW cooling4,349 kWh/yr4.5$1,435
Rinnai DONSR11B1/DINLR11B111.5 kW heating10.5 kW cooling4,403 kWh/yr4.5$1,453
Actron Air LRC-100CS / LRE-100CS11.5 kW heating10.5 kW cooling4,311 kWh/yr4.5$1,423
Rinnai DONSR11B1/DINLR11B111.5 kW heating10.5 kW cooling4,404 kWh/yr4.5$1,453
Midea DUCMI105IB/UCMI105OB11 kW heating10.5 kW cooling4,207 kWh/yr4.5$1,388
Midea DUCMI105IHB/UCMI105OB11 kW heating10.5 kW cooling4,207 kWh/yr4.5$1,388
Kaden KDI3611.5 kW heating10.5 kW cooling4,565 kWh/yr3$1,506
Kaden KDI36 / KDI3611.5 kW heating10.5 kW cooling4,427 kWh/yr4.5$1,461

Compare C-UV-105N8-QC3W / CDV-105HN8-QC3W with another model

Mdv specifications

Type
Reverse cycle
Configuration
Split system
Air distribution
Ducted
Indoor unit
–
Rated cooling capacity (35 Β°C)
10.50 kW
Cooling power input
3.10 kW
Rated heating capacity (7 Β°C)
11.00 kW
Heating power input
2.70 kW
EER, full load (tested)
3.33
COP, full load (tested)
4.09
Rated AEER
3.35
Rated ACOP
4.02
Standby power (PIA)
10.0 W
Compressor
Variable speed, Inverter
Refrigerant
R32
Power supply
Single phase
Indoor sound power
–
Outdoor sound power
68.1 dB(A)
Demand response (AS/NZS 4755)
Yes
Country of manufacture
China

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

Mdv zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––-1421,209
Coldresidential4.52.04383,806
Mixedcommercial––529629
Mixedresidential4.02.57251,401
Hotcommercial––743140
Hotresidential5.53.01,817214
Part-load test points (25 values)
c__t1_min_cap_power_rated
615 W
h__h1_min_cap_power_rated
490 W
h__h2_ext_cap_power_rated
3330 W
c__t1_half_cap_power_rated
1650 W
c__t1_have_min_cap_results
Yes
h__h1_half_cap_power_rated
1080 W
h__h1_have_min_cap_results
Yes
h__h3_have_ext_cap_results
No
h__h2_have_full_cap_results
No
h__h2_have_half_cap_results
No
h__h3_have_full_cap_results
No
h__h3_have_half_cap_results
No
h__h1_min_cap_heat_cap_rated
2300 W
h__h2_ext_cap_heat_cap_rated
9750 W
h__h1_half_cap_heat_cap_rated
5600 W
h__h2_is_capable_extended_load
Yes
c__low_temp_min_cap_power_rated
350 W
c__t1_min_cap_cooling_cap_rated
2580 W
c__low_temp_full_cap_power_rated
2833.4 W
c__low_temp_half_cap_power_rated
710 W
c__t1_half_cap_cooling_cap_rated
5100 W
c__low_temp_have_half_cap_results
Yes
c__low_temp_min_cap_cooling_cap_rated
2630 W
c__low_temp_full_cap_cooling_cap_rated
11308.5 W
c__low_temp_half_cap_cooling_cap_rated
5090 W

New Zealand E3 registration details

Registration number
AAC7220
GEMS registration id
151595
Status
approved, available (self-reported)
Registration expires
2 January 2028
Registered for sale in
Australia, Fiji, New Zealand
Family
–
Regulatory standard
[SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
Test standard
AS/NZS 3823.1.2:2012
MEPS
2019
Product class
Class 11

Source: E3 programme registration data (EECA, New Zealand) (trans-Tasman E3 registration data published by DCCEEW on data.gov.au, CC BY 3.0 AU). Dataset published 25 September 2026; last checked 26 September 2026. How the derived figures are calculated.