c/kWh
Energy rating (cooling)
4.5
Heating: 2
Annual electricity use
4,427 kWh
462 cooling + 3,965 heating
Estimated running cost
$1,461 / year
$122 / month Β· $14,609 over 10 years
Capacity
10.5 kW cooling
11.5 kW heating

7% less electricity than the median of 136 comparable 10 kW reverse cycle ducted split system registrations (4,758 kWh a year) in the cold zone. Uses less than 74% of them.

Across all 3,611 air conditioner registrations sold in Australia, it uses less than 44% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ— 33c/kWh in NZD; change the price above to your tariff.

Kaden KDI36 running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 4,427$1,461$14,609
Mixed zone 2,174$717$7,174
Hot zone 2,174$717$7,174

At 33c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Heat pumps that use less electricity

Same configuration and type, cooling capacity within 12% of 10.5 kW, at least 3% lower annual kWh in the cold zone.

ModelStarsEst. cost / yrCompare
Panasonic U-100PZ3R8 / S-1014PF3E9.5 kW heating9.5 kW cooling3,634 kWh/yr3$1,199
Panasonic U-100PZ4R8 / S-1014PF3E9.5 kW heating9.5 kW cooling3,634 kWh/yr3$1,199
Brivis AONSR13B1/AINHU11B111.3 kW heating10.3 kW cooling3,713 kWh/yr5$1,225
Midea UCMI90OB/DUCMI90IB11 kW heating10.5 kW cooling4,207 kWh/yr4.5$1,388
Midea DUCMI105IHB/UCMI105OB11 kW heating10.5 kW cooling4,207 kWh/yr4.5$1,388

Heat pumps similar to the Kaden KDI36

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
Midea DUCMI105IHB/UCMI105OB11 kW heating10.5 kW cooling4,207 kWh/yr4.5$1,388
Actron Air LRC-100CS / LRE-100CS11.5 kW heating10.5 kW cooling4,311 kWh/yr4.5$1,423
Rinnai DONSR11B1/DINLR11B111.5 kW heating10.5 kW cooling4,404 kWh/yr4.5$1,453
Midea DUCMI105IB/UCMI105OB11 kW heating10.5 kW cooling4,207 kWh/yr4.5$1,388
Mdv C-UV-105N8-QC3W / CDV-105HN8-QC3W11 kW heating10.5 kW cooling4,244 kWh/yr4.5$1,401
Mdv C-UV-105N8-QC3W / CDV-105A6N8-QC3W11 kW heating10.5 kW cooling4,253 kWh/yr4.5$1,403
Rinnai DONSR11B1/DINLR11B111.5 kW heating10.5 kW cooling4,403 kWh/yr4.5$1,453
Aurora AU-BS36HR-2A-O / AU-LCF36-2A-I11.5 kW heating10.5 kW cooling4,349 kWh/yr4.5$1,435

Compare KDI36 / KDI36 with another model

Kaden KDI36 specifications

Type
Reverse cycle
Configuration
Split system
Air distribution
Ducted
Indoor unit
–
Rated cooling capacity (35 Β°C)
10.50 kW
Cooling power input
3.10 kW
Rated heating capacity (7 Β°C)
11.50 kW
Heating power input
2.70 kW
EER, full load (tested)
3.27
COP, full load (tested)
4.17
Rated AEER
3.35
Rated ACOP
4.21
Standby power (PIA)
10.0 W
Compressor
Variable speed, Inverter
Refrigerant
R32
Power supply
Single phase
Indoor sound power
–
Outdoor sound power
68 dB(A)
Demand response (AS/NZS 4755)
Yes
Country of manufacture
China

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

Kaden KDI36 zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––-4211,231
Coldresidential4.52.04623,965
Mixedcommercial––128627
Mixedresidential4.02.57381,436
Hotcommercial––1,775138
Hotresidential5.03.51,959215
Part-load test points (25 values)
c__t1_min_cap_power_rated
735 W
h__h1_min_cap_power_rated
480 W
h__h2_ext_cap_power_rated
3300 W
c__t1_half_cap_power_rated
1830 W
c__t1_have_min_cap_results
Yes
h__h1_half_cap_power_rated
1120 W
h__h1_have_min_cap_results
Yes
h__h3_have_ext_cap_results
No
h__h2_have_full_cap_results
No
h__h2_have_half_cap_results
No
h__h3_have_full_cap_results
No
h__h3_have_half_cap_results
No
h__h1_min_cap_heat_cap_rated
2470 W
h__h2_ext_cap_heat_cap_rated
9780 W
h__h1_half_cap_heat_cap_rated
5750 W
h__h2_is_capable_extended_load
Yes
c__low_temp_min_cap_power_rated
350 W
c__t1_min_cap_cooling_cap_rated
2670 W
c__low_temp_full_cap_power_rated
2833.4 W
c__low_temp_half_cap_power_rated
850 W
c__t1_half_cap_cooling_cap_rated
5150 W
c__low_temp_have_half_cap_results
Yes
c__low_temp_min_cap_cooling_cap_rated
2500 W
c__low_temp_full_cap_cooling_cap_rated
11308.5 W
c__low_temp_half_cap_cooling_cap_rated
5180 W

New Zealand E3 registration details

Registration number
AAC7192
GEMS registration id
151479
Status
approved, available (self-reported)
Registration expires
4 December 2027
Registered for sale in
Australia, Fiji, New Zealand
Family
–
Regulatory standard
[SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
Test standard
AS/NZS 3823.1.2:2012
MEPS
2019
Product class
Class 11

Source: E3 programme registration data (EECA, New Zealand) (trans-Tasman E3 registration data published by DCCEEW on data.gov.au, CC BY 3.0 AU). Dataset published 25 September 2026; last checked 26 September 2026. Manufacturer: reece.com.au. How the derived figures are calculated.