c/kWh
Energy rating (cooling)
1.5
Heating: 1
Annual electricity use
15,843 kWh
2,479 cooling + 13,364 heating
Estimated running cost
$5,228 / year
$436 / month Β· $52,282 over 10 years
Capacity
28.3 kW cooling
28.6 kW heating

21% more electricity than the median of 15 comparable 25 kW reverse cycle ducted split system registrations (13,045 kWh a year) in the cold zone. Uses less than 0% of them.

Across all 3,612 air conditioner registrations sold in Australia, it uses less than 8% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ— 33c/kWh in NZD; change the price above to your tariff.

Actron Air SCA290C running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 15,843$5,228$52,282
Mixed zone 8,996$2,969$29,687
Hot zone 11,570$3,818$38,181

At 33c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Heat pumps that use less electricity

Same configuration and type, cooling capacity within 12% of 28.3 kW, at least 3% lower annual kWh in the cold zone.

ModelStarsEst. cost / yrCompare
Actron Air CRV25BT / EVV25BS26 kW heating25 kW cooling11,248 kWh/yr3$3,712
Actron Air CRV25BT / EAA25BS & EFV25BS26 kW heating25 kW cooling11,248 kWh/yr3$3,712
Fujitsu AOTA90LALT/ARTC90LATU28 kW heating25 kW cooling14,958 kWh/yr1.5$4,936

Heat pumps similar to the Actron Air SCA290C

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
Temperzone ISD 351LYX / OSA 352RLTFV31.3 kW heating31.5 kW cooling16,096 kWh/yr1.5$5,312
Fujitsu AOTA90LALT/ARTC90LATU28 kW heating25 kW cooling14,958 kWh/yr1.5$4,936

Other Actron Air models of similar capacity

ModelStarsEst. cost / yrCompare
Actron Air CRV290T / EVA290T29.8 kW heating29.6 kW cooling15,167 kWh/yr2$5,005
Actron Air CRV25BT / EVV25BS26 kW heating25 kW cooling11,248 kWh/yr3$3,712

Compare SCA290C / SCG290E with another model

Actron Air SCA290C specifications

Type
Reverse cycle
Configuration
Split system
Air distribution
Ducted
Indoor unit
–
Rated cooling capacity (35 Β°C)
28.30 kW
Cooling power input
8.45 kW
Rated heating capacity (7 Β°C)
28.60 kW
Heating power input
7.97 kW
EER, full load (tested)
3.31
COP, full load (tested)
3.69
Rated AEER
3.28
Rated ACOP
3.51
Standby power (PIA)
55.0 W
Compressor
Fixed speed
Refrigerant
R410A
Power supply
Three phase
Indoor sound power
–
Outdoor sound power
–
Demand response (AS/NZS 4755)
Yes (requires additional part)
Country of manufacture
Australia

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

Actron Air SCA290C zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––5,5454,519
Coldresidential1.51.02,47913,364
Mixedcommercial––6,8102,468
Mixedresidential1.51.53,7085,288
Hotcommercial––14,573600
Hotresidential1.51.510,647923
Part-load test points (4 values)
h__h2_full_cap_power_rated
6811 W
h__h3_have_full_cap_results
No
h__h2_full_cap_heat_cap_rated
21853 W
c__low_temp_have_full_cap_results
No

New Zealand E3 registration details

Registration number
AAC9954
GEMS registration id
177564
Status
approved, available (self-reported)
Registration expires
12 August 2031
Registered for sale in
Australia, New Zealand
Family
–
Regulatory standard
[SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
Test standard
AS/NZS 3823.1.2:2012
MEPS
2019
Product class
Class 11

Source: E3 programme registration data (EECA, New Zealand) (trans-Tasman E3 registration data published by DCCEEW on data.gov.au, CC BY 3.0 AU). Dataset published 25 September 2026; last checked 26 September 2026. Manufacturer: actronair.com.au. How the derived figures are calculated.