c/kWh
Energy rating (cooling)
3.5
Heating: 2
Annual electricity use
5,661 kWh
711 cooling + 4,950 heating
Estimated running cost
$1,868 / year
$156 / month Β· $18,681 over 10 years
Capacity
14.1 kW cooling
14.5 kW heating

15% less electricity than the median of 66 comparable 14 kW reverse cycle split system registrations (6,658 kWh a year) in the cold zone. Uses less than 92% of them.

Across all 3,611 air conditioner registrations sold in Australia, it uses less than 34% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ— 33c/kWh in NZD; change the price above to your tariff.

Actron Air URC-140DS running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 5,661$1,868$18,681
Mixed zone 2,992$987$9,874
Hot zone 3,523$1,163$11,626

At 33c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Heat pumps that use less electricity

Same configuration and type, cooling capacity within 12% of 14.1 kW, at least 3% lower annual kWh in the cold zone.

ModelStarsEst. cost / yrCompare
Panasonic U-125PZ4R5 / S-1014PU3E12.5 kW heating12.5 kW cooling4,631 kWh/yr3$1,528
Panasonic U-125PZ4R8 / S-1014PU3E12.5 kW heating12.5 kW cooling4,631 kWh/yr3$1,528
Mdv C-UV-125N8-QC3W / CSV-125N8-QC3W13 kW heating12.5 kW cooling5,013 kWh/yr4$1,654
Kaden KDI42 / KCI4213 kW heating12.5 kW cooling5,013 kWh/yr4$1,654
Daikin RZAV125FV1 / FCTA125AVMA15 kW heating12.5 kW cooling5,020 kWh/yr4$1,657

Heat pumps similar to the Actron Air URC-140DS

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
Midea UCMI140OC/CASMI140IC14.5 kW heating14.1 kW cooling5,694 kWh/yr3.5$1,879
Mdv C-UV-140N8-QC3W / CSV-140N8-QC3W14.5 kW heating14 kW cooling5,771 kWh/yr4$1,904
Hitachi PAS-6.0UFASNQ1 / PCI-6.0UFA1NQ16 kW heating14 kW cooling6,604 kWh/yr3$2,179
Kaden KDI48 / KCI4814.5 kW heating14 kW cooling5,771 kWh/yr4$1,904
Daikin RZAV140F2Y1 / FCA140CVMA16.5 kW heating14 kW cooling5,814 kWh/yr4$1,919
Daikin RZAV140FY1 / FCA140CVMA16.5 kW heating14 kW cooling5,812 kWh/yr4$1,918
Panasonic U-140PZ4R5 / S-1014PU3E14 kW heating14 kW cooling5,410 kWh/yr3$1,785
Panasonic U-140PZ4R8 / S-1014PU3E14 kW heating14 kW cooling5,410 kWh/yr3$1,785

Compare URC-140DS / CRE-140DS with another model

Actron Air URC-140DS specifications

Type
Reverse cycle
Configuration
Split system
Air distribution
Non-ducted
Indoor unit
Cassette
Rated cooling capacity (35 Β°C)
14.10 kW
Cooling power input
4.25 kW
Rated heating capacity (7 Β°C)
14.50 kW
Heating power input
4.00 kW
EER, full load (tested)
3.23
COP, full load (tested)
3.64
Rated AEER
3.30
Rated ACOP
3.60
Standby power (PIA)
8.5 W
Compressor
Variable speed, Inverter
Refrigerant
R32
Power supply
Single phase
Indoor sound power
65 dB(A)
Outdoor sound power
70.2 dB(A)
Demand response (AS/NZS 4755)
Yes
Country of manufacture
China

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

Actron Air URC-140DS zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––8711,526
Coldresidential3.52.07114,950
Mixedcommercial––1,471792
Mixedresidential3.52.51,1391,853
Hotcommercial––3,638166
Hotresidential4.03.53,262261
Part-load test points (23 values)
c__t1_min_cap_power_rated
780 W
h__h1_min_cap_power_rated
695 W
h__h2_ext_cap_power_rated
5310 W
c__t1_half_cap_power_rated
1800 W
c__t1_have_min_cap_results
Yes
h__h1_half_cap_power_rated
1365 W
h__h1_have_min_cap_results
Yes
h__h3_have_ext_cap_results
No
h__h2_have_full_cap_results
No
h__h2_have_half_cap_results
No
h__h3_have_full_cap_results
No
h__h3_have_half_cap_results
No
h__h1_min_cap_heat_cap_rated
3650 W
h__h2_ext_cap_heat_cap_rated
14850 W
h__h1_half_cap_heat_cap_rated
7050 W
h__h2_is_capable_extended_load
Yes
c__low_temp_min_cap_power_rated
520 W
c__t1_min_cap_cooling_cap_rated
3600 W
c__low_temp_half_cap_power_rated
1120 W
c__t1_half_cap_cooling_cap_rated
7000 W
c__low_temp_have_half_cap_results
Yes
c__low_temp_min_cap_cooling_cap_rated
3700 W
c__low_temp_half_cap_cooling_cap_rated
7040 W

New Zealand E3 registration details

Registration number
AAC9029
GEMS registration id
170380
Status
approved, available (self-reported)
Registration expires
22 June 2030
Registered for sale in
Australia, New Zealand
Family
–
Regulatory standard
[SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
Test standard
AS/NZS 3823.1.1:2012
MEPS
2019
Product class
Class 11

Source: E3 programme registration data (EECA, New Zealand) (trans-Tasman E3 registration data published by DCCEEW on data.gov.au, CC BY 3.0 AU). Dataset published 25 September 2026; last checked 26 September 2026. Manufacturer: actronair.com.au. How the derived figures are calculated.