c/kWh
Energy rating (cooling)
3.5
Heating: 2
Annual electricity use
5,694 kWh
711 cooling + 4,983 heating
Estimated running cost
$1,879 / year
$157 / month Β· $18,790 over 10 years
Capacity
14.1 kW cooling
14.5 kW heating

14% less electricity than the median of 66 comparable 14 kW reverse cycle split system registrations (6,658 kWh a year) in the cold zone. Uses less than 91% of them.

Across all 3,611 air conditioner registrations sold in Australia, it uses less than 34% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ— 33c/kWh in NZD; change the price above to your tariff.

Midea UCMI140OC running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 5,694$1,879$18,790
Mixed zone 2,985$985$9,851
Hot zone 3,499$1,155$11,547

At 33c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Heat pumps that use less electricity

Same configuration and type, cooling capacity within 12% of 14.1 kW, at least 3% lower annual kWh in the cold zone.

ModelStarsEst. cost / yrCompare
Panasonic U-125PZ4R5 / S-1014PU3E12.5 kW heating12.5 kW cooling4,631 kWh/yr3$1,528
Panasonic U-125PZ4R8 / S-1014PU3E12.5 kW heating12.5 kW cooling4,631 kWh/yr3$1,528
Kaden KDI42 / KCI4213 kW heating12.5 kW cooling5,013 kWh/yr4$1,654
Mdv C-UV-125N8-QC3W / CSV-125N8-QC3W13 kW heating12.5 kW cooling5,013 kWh/yr4$1,654
Daikin RZAV125FV1 / FCTA125AVMA15 kW heating12.5 kW cooling5,020 kWh/yr4$1,657

Heat pumps similar to the Midea UCMI140OC

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
Actron Air URC-140DS / CRE-140DS14.5 kW heating14.1 kW cooling5,661 kWh/yr3.5$1,868
Kaden KDI48 / KCI4814.5 kW heating14 kW cooling5,771 kWh/yr4$1,904
Hitachi PAS-6.0UFASNQ1 / PCI-6.0UFA1NQ16 kW heating14 kW cooling6,604 kWh/yr3$2,179
Daikin RZAV140F2Y1 / FCA140CVMA16.5 kW heating14 kW cooling5,814 kWh/yr4$1,919
Daikin RZAV140FY1 / FCA140CVMA16.5 kW heating14 kW cooling5,812 kWh/yr4$1,918
Panasonic U-140PZ4R5 / S-1014PU3E14 kW heating14 kW cooling5,410 kWh/yr3$1,785
Panasonic U-140PZ4R8 / S-1014PU3E14 kW heating14 kW cooling5,410 kWh/yr3$1,785
Mdv C-UV-140N8-QC3W / CSV-140N8-QC3W14.5 kW heating14 kW cooling5,771 kWh/yr4$1,904

Compare UCMI140OC/CASMI140IC with another model

Midea UCMI140OC specifications

Type
Reverse cycle
Configuration
Split system
Air distribution
Non-ducted
Indoor unit
Cassette
Rated cooling capacity (35 Β°C)
14.10 kW
Cooling power input
4.28 kW
Rated heating capacity (7 Β°C)
14.50 kW
Heating power input
3.92 kW
EER, full load (tested)
3.27
COP, full load (tested)
3.68
Rated AEER
3.27
Rated ACOP
3.67
Standby power (PIA)
8.2 W
Compressor
Variable speed, Inverter
Refrigerant
R32
Power supply
Single phase
Indoor sound power
66.6 dB(A)
Outdoor sound power
72 dB(A)
Demand response (AS/NZS 4755)
Yes
Country of manufacture
China

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

Midea UCMI140OC zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––6741,529
Coldresidential3.52.07114,983
Mixedcommercial––1,312788
Mixedresidential3.52.51,1341,851
Hotcommercial––3,459164
Hotresidential4.03.53,239260
Part-load test points (23 values)
c__t1_min_cap_power_rated
980 W
h__h1_min_cap_power_rated
720 W
h__h2_ext_cap_power_rated
5050 W
c__t1_half_cap_power_rated
1975 W
c__t1_have_min_cap_results
Yes
h__h1_half_cap_power_rated
1400 W
h__h1_have_min_cap_results
Yes
h__h3_have_ext_cap_results
No
h__h2_have_full_cap_results
No
h__h2_have_half_cap_results
No
h__h3_have_full_cap_results
No
h__h3_have_half_cap_results
No
h__h1_min_cap_heat_cap_rated
3850 W
h__h2_ext_cap_heat_cap_rated
14200 W
h__h1_half_cap_heat_cap_rated
7100 W
h__h2_is_capable_extended_load
Yes
c__low_temp_min_cap_power_rated
590 W
c__t1_min_cap_cooling_cap_rated
3600 W
c__low_temp_half_cap_power_rated
1190 W
c__t1_half_cap_cooling_cap_rated
6700 W
c__low_temp_have_half_cap_results
Yes
c__low_temp_min_cap_cooling_cap_rated
3980 W
c__low_temp_half_cap_cooling_cap_rated
7150 W

New Zealand E3 registration details

Registration number
AAC9172
GEMS registration id
170224
Status
approved, available (self-reported)
Registration expires
4 August 2030
Registered for sale in
Australia, Fiji, New Zealand
Family
–
Regulatory standard
[SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
Test standard
AS/NZS 3823.1.1:2012
MEPS
2019
Product class
Class 11

Source: E3 programme registration data (EECA, New Zealand) (trans-Tasman E3 registration data published by DCCEEW on data.gov.au, CC BY 3.0 AU). Dataset published 19 September 2026; last checked 20 September 2026. How the derived figures are calculated.