New Zealand Β· costs in NZD

Reverse cycle split system air conditioner, wall hung
Actron Air WRC-050CS / WRE-050CS Heat Pump
Actron Air WRC-050CS / WRE-050CS is a 5 kW reverse cycle split system heat pump registered for sale in New Zealand under the trans-Tasman E3 energy rating scheme (registration AAC9191).
- Energy rating (cooling)
- 5
- Heating: 2
- Annual electricity use
- 1,936 kWh
- 211 cooling + 1,725 heating
- Estimated running cost
- $639 / year
- $53 / month Β· $6,389 over 10 years
- Capacity
- 5 kW cooling
- 5 kW heating
10% less electricity than the median of 236 comparable 5 kW reverse cycle split system registrations (2,154 kWh a year) in the cold zone. Uses less than 89% of them.
Across all 3,611 air conditioner registrations sold in Australia, it uses less than 77% (this compares very different sizes, so the cohort figure above is the useful one).
Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ 33c/kWh in NZD; change the price above to your tariff.
Actron Air WRC-050CS running cost by climate zone
| Climate zone | kWh / year | Per year | 10 years |
|---|---|---|---|
| Cold zone | 1,936 | $639 | $6,389 |
| Mixed zone | 942 | $311 | $3,109 |
| Hot zone | 1,068 | $352 | $3,524 |
At 33c/kWh. Formula: cost = annual kWh Γ price. The kWh figure is the labelβs residential estimate for that zone; commercial-profile figures are in the specifications.
Heat pumps that use less electricity
Same configuration and type, cooling capacity within 12% of 5 kW, at least 3% lower annual kWh in the cold zone.
| Model | Stars | Est. cost / yr | Compare |
|---|---|---|---|
| Daikin RXM46AVMA / FTXM46AVMA4.7 kW heating4.6 kW cooling1,543 kWh/yr | 4.5 | $509 | |
| Daikin RXM46WVMA / FTXM46WVMA4.7 kW heating4.6 kW cooling1,571 kWh/yr | 4.5 | $518 | |
| Gree GWH15AGDXD-K6DNA1A/O / GWH15AGDXD-K6DNA1A/I4.7 kW heating4.6 kW cooling1,835 kWh/yr | 4 | $606 | |
| Gree GWH15QDXE4.7 kW heating4.6 kW cooling1,839 kWh/yr | 3 | $607 | |
| Midea MFCA50VA-W/MFCA50VA-N5.2 kW heating5.2 kW cooling1,841 kWh/yr | 4.5 | $608 |
Heat pumps similar to the Actron Air WRC-050CS
Technically comparable registrations: same configuration and type, capacity within 12%.
| Model | Stars | Est. cost / yr | Compare |
|---|---|---|---|
| Hisense HAWG18KR5.3 kW heating5 kW cooling1,993 kWh/yr | 4 | $658 | |
| Pioneer International HPR-18A25.1 kW heating5 kW cooling1,968 kWh/yr | 4 | $649 | |
| Kaden KS185.1 kW heating5 kW cooling2,008 kWh/yr | 3.5 | $663 | |
| Panasonic CU-HZ50DKR / CS-HZ50DKR6 kW heating5 kW cooling1,940 kWh/yr | 5.5 | $640 | |
| Daikin RXM50WVMA / FTXM50WVMA6 kW heating5 kW cooling1,903 kWh/yr | 5 | $628 | |
| Daikin RXM50AVMA / FTXM50AVMA6 kW heating5 kW cooling1,881 kWh/yr | 5.5 | $621 | |
| LG LS18S0U DX6ALAP/LS18S0N DX6ALAP5.1 kW heating5 kW cooling2,018 kWh/yr | 3 | $666 | |
| Haier 1U50PFHRA / AS50PFHRA5.3 kW heating5 kW cooling1,973 kWh/yr | 4 | $651 |
Compare WRC-050CS / WRE-050CS with another model
Actron Air WRC-050CS specifications
- Type
- Reverse cycle
- Configuration
- Split system
- Air distribution
- Non-ducted
- Indoor unit
- Wall hung
- Rated cooling capacity (35 Β°C)
- 5.00 kW
- Cooling power input
- 1.17 kW
- Rated heating capacity (7 Β°C)
- 5.00 kW
- Heating power input
- 1.16 kW
- EER, full load (tested)
- 4.23
- COP, full load (tested)
- 4.22
- Rated AEER
- 4.26
- Rated ACOP
- 4.30
- Standby power (PIA)
- 1.0 W
- Compressor
- Variable speed, Inverter
- Refrigerant
- R32
- Power supply
- Single phase
- Indoor sound power
- 58 dB(A)
- Outdoor sound power
- 67 dB(A)
- Demand response (AS/NZS 4755)
- Yes
- Country of manufacture
- China
Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.
Actron Air WRC-050CS zoned energy rating figures
As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.
| Zone | Profile | Cooling stars | Heating stars | Cooling kWh | Heating kWh |
|---|---|---|---|---|---|
| Coldcommercial | commercial | β | β | 315 | 535 |
| Coldresidential | residential | 5.0 | 2.0 | 211 | 1,725 |
| Mixedcommercial | commercial | β | β | 469 | 269 |
| Mixedresidential | residential | 4.5 | 2.5 | 333 | 609 |
| Hotcommercial | commercial | β | β | 1,204 | 54 |
| Hotresidential | residential | 5.0 | 3.5 | 983 | 85 |
Part-load test points (23 values)
- c__t1_min_cap_power_rated
- 445 W
- h__h1_min_cap_power_rated
- 290 W
- h__h2_ext_cap_power_rated
- 1560 W
- c__t1_half_cap_power_rated
- 510 W
- c__t1_have_min_cap_results
- Yes
- h__h1_half_cap_power_rated
- 480 W
- h__h1_have_min_cap_results
- Yes
- h__h3_have_ext_cap_results
- No
- h__h2_have_full_cap_results
- No
- h__h2_have_half_cap_results
- No
- h__h3_have_full_cap_results
- No
- h__h3_have_half_cap_results
- No
- h__h1_min_cap_heat_cap_rated
- 1500 W
- h__h2_ext_cap_heat_cap_rated
- 4260 W
- h__h1_half_cap_heat_cap_rated
- 2580 W
- h__h2_is_capable_extended_load
- Yes
- c__low_temp_min_cap_power_rated
- 300 W
- c__t1_min_cap_cooling_cap_rated
- 2150 W
- c__low_temp_half_cap_power_rated
- 410 W
- c__t1_half_cap_cooling_cap_rated
- 2550 W
- c__low_temp_have_half_cap_results
- Yes
- c__low_temp_min_cap_cooling_cap_rated
- 2360 W
- c__low_temp_half_cap_cooling_cap_rated
- 2960 W
New Zealand E3 registration details
- Registration number
- AAC9191
- GEMS registration id
- 171658
- Status
- approved, available (self-reported)
- Registration expires
- 20 August 2030
- Registered for sale in
- Australia, New Zealand
- Family
- β
- Regulatory standard
- [SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
- Test standard
- AS/NZS 3823.1.1:2012
- MEPS
- 2019
- Product class
- Class 9
Source: E3 programme registration data (EECA, New Zealand) (trans-Tasman E3 registration data published by DCCEEW on data.gov.au, CC BY 3.0 AU). Dataset published 25 September 2026; last checked 26 September 2026. Manufacturer: actronair.com.au. How the derived figures are calculated.