c/kWh
Energy rating (cooling)
3.5
Heating: 2
Annual electricity use
2,008 kWh
268 cooling + 1,740 heating
Estimated running cost
$663 / year
$55 / month Β· $6,626 over 10 years
Capacity
5 kW cooling
5.1 kW heating

7% less electricity than the median of 236 comparable 5 kW reverse cycle split system registrations (2,154 kWh a year) in the cold zone. Uses less than 82% of them.

Across all 3,612 air conditioner registrations sold in Australia, it uses less than 77% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ— 33c/kWh in NZD; change the price above to your tariff.

Kaden KS18 running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 2,008$663$6,626
Mixed zone 1,063$351$3,508
Hot zone 1,352$446$4,462

At 33c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Heat pumps that use less electricity

Same configuration and type, cooling capacity within 12% of 5 kW, at least 3% lower annual kWh in the cold zone.

ModelStarsEst. cost / yrCompare
Daikin RXM46AVMA / FTXM46AVMA4.7 kW heating4.6 kW cooling1,543 kWh/yr4.5$509
Daikin RXM46WVMA / FTXM46WVMA4.7 kW heating4.6 kW cooling1,571 kWh/yr4.5$518
Gree GWH15AGDXD-K6DNA1A/O / GWH15AGDXD-K6DNA1A/I4.7 kW heating4.6 kW cooling1,835 kWh/yr4$606
Gree GWH15QDXE-K6DNA1A/O / GWH15QDXE-K6DNA1A/I4.7 kW heating4.6 kW cooling1,839 kWh/yr3$607
Midea MFCA50VA-W/MFCA50VA-N5.2 kW heating5.2 kW cooling1,841 kWh/yr4.5$608

Heat pumps similar to the Kaden KS18

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
Actron Air WRC-050CS / WRE-050CS5 kW heating5 kW cooling1,936 kWh/yr5$639
LG LS18S0U DX6ALAP/LS18S0N DX6ALAP5.1 kW heating5 kW cooling2,018 kWh/yr3$666
Daikin RXM50AVMA / FTXM50AVMA6 kW heating5 kW cooling1,881 kWh/yr5.5$621
Daikin RXM50WVMA / FTXM50WVMA6 kW heating5 kW cooling1,903 kWh/yr5$628
Haier 1U50PFHRA / AS50PFHRA5.3 kW heating5 kW cooling1,973 kWh/yr4$651
Hisense HAWG18KR5.3 kW heating5 kW cooling1,993 kWh/yr4$658
Pioneer International HPR-18A25.1 kW heating5 kW cooling1,968 kWh/yr4$649
Panasonic CU-HZ50DKR / CS-HZ50DKR6 kW heating5 kW cooling1,940 kWh/yr5.5$640

Compare KS18 with another model

Kaden KS18 specifications

Type
Reverse cycle
Configuration
Split system
Air distribution
Non-ducted
Indoor unit
Wall hung
Rated cooling capacity (35 Β°C)
5.00 kW
Cooling power input
1.35 kW
Rated heating capacity (7 Β°C)
5.10 kW
Heating power input
1.35 kW
EER, full load (tested)
3.67
COP, full load (tested)
3.75
Rated AEER
3.69
Rated ACOP
3.77
Standby power (PIA)
1.0 W
Compressor
Variable speed, Inverter
Refrigerant
R410A
Power supply
Single phase
Indoor sound power
62 dB(A)
Outdoor sound power
63 dB(A)
Demand response (AS/NZS 4755)
No
Country of manufacture
China

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

Kaden KS18 zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––428540
Coldresidential3.52.02681,740
Mixedcommercial––605279
Mixedresidential3.52.5414649
Hotcommercial––1,62756
Hotresidential3.53.01,26389
Part-load test points (25 values)
c__t1_min_cap_power_rated
420 W
h__h1_min_cap_power_rated
265 W
h__h2_ext_cap_power_rated
1300 W
c__t1_half_cap_power_rated
555 W
c__t1_have_min_cap_results
Yes
h__h1_half_cap_power_rated
550 W
h__h1_have_min_cap_results
Yes
h__h3_have_ext_cap_results
No
h__h2_have_full_cap_results
No
h__h2_have_half_cap_results
No
h__h3_have_full_cap_results
No
h__h3_have_half_cap_results
No
h__h1_min_cap_heat_cap_rated
1360 W
h__h2_ext_cap_heat_cap_rated
4510 W
h__h1_half_cap_heat_cap_rated
2700 W
h__h2_is_capable_extended_load
Yes
c__low_temp_min_cap_power_rated
285 W
c__t1_min_cap_cooling_cap_rated
1640 W
c__low_temp_full_cap_power_rated
1233.9 W
c__low_temp_half_cap_power_rated
507.27000000000004 W
c__t1_half_cap_cooling_cap_rated
2500 W
c__low_temp_have_half_cap_results
No
c__low_temp_min_cap_cooling_cap_rated
1860 W
c__low_temp_full_cap_cooling_cap_rated
5385 W
c__low_temp_half_cap_cooling_cap_rated
2692.5 W

New Zealand E3 registration details

Registration number
AAC6823
GEMS registration id
148144
Status
approved, available (self-reported)
Registration expires
17 July 2027
Registered for sale in
Australia, Fiji, New Zealand
Family
–
Regulatory standard
[SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
Test standard
AS/NZS 3823.1.1:2012
MEPS
2019
Product class
Class 9

Source: E3 programme registration data (EECA, New Zealand) (trans-Tasman E3 registration data published by DCCEEW on data.gov.au, CC BY 3.0 AU). Dataset published 25 September 2026; last checked 26 September 2026. Manufacturer: midea.com/global. How the derived figures are calculated.