c/kWh
Energy rating (cooling)
1.5
Heating: 1
Annual electricity use
10,040 kWh
1,534 cooling + 8,506 heating
Estimated running cost
$3,313 / year
$276 / month Β· $33,132 over 10 years
Capacity
18.1 kW cooling
18.7 kW heating

4% more electricity than the median of 10 comparable 18 kW reverse cycle ducted packaged registrations (9,688 kWh a year) in the cold zone. Uses less than 30% of them.

Across all 3,611 air conditioner registrations sold in Australia, it uses less than 14% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ— 33c/kWh in NZD; change the price above to your tariff.

AIRSTAGE RAQ running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 10,040$3,313$33,132
Mixed zone 5,711$1,885$18,846
Hot zone 7,319$2,415$24,153

At 33c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Heat pumps that use less electricity

Same configuration and type, cooling capacity within 12% of 18.1 kW, at least 3% lower annual kWh in the cold zone.

ModelStarsEst. cost / yrCompare
Temperzone OPA 171RLTFY17.3 kW heating16.4 kW cooling7,720 kWh/yr2.5$2,548
APAC P015AHR3SA-RTT14.2 kW heating16 kW cooling7,837 kWh/yr1.5$2,586
APAC P015AHR3SA-LBB14.2 kW heating16 kW cooling7,837 kWh/yr1.5$2,586
Temperzone OPA 171RLTFY17.3 kW heating16.4 kW cooling8,061 kWh/yr2.5$2,660
Actron Air PRV19BT-T19 kW heating19 kW cooling8,350 kWh/yr2.5$2,756

Heat pumps similar to the AIRSTAGE RAQ

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
Temperzone OPA186RKTY16.7 kW heating18.2 kW cooling9,328 kWh/yr1.5$3,078
APAC P018AHR3TA-RI2061A17.8 kW heating17.8 kW cooling8,965 kWh/yr2$2,958
APAC P018AHR3TA-17.8 kW heating17.8 kW cooling8,965 kWh/yr2$2,958
Temperzone OPA 186RKTYG17.5 kW heating17.8 kW cooling9,913 kWh/yr1.5$3,271
Daikin UAYN180AFY1A17.2 kW heating17.4 kW cooling10,894 kWh/yr1$3,595
Actron Air PRV19BT-T19 kW heating19 kW cooling8,350 kWh/yr2.5$2,756

Other AIRSTAGE models of similar capacity

ModelStarsEst. cost / yrCompare
AIRSTAGE RAQ/K/WP/* 1718.5 kW heating17.9 kW cooling10,380 kWh/yr1.5$3,425
AIRSTAGE RAQ/K/WP/ECO/1718.5 kW heating17.9 kW cooling10,380 kWh/yr1.5$3,425

Compare RAQ/K/EC/WP/*17 with another model

AIRSTAGE RAQ specifications

Type
Reverse cycle
Configuration
Packaged
Air distribution
Ducted
Indoor unit
–
Rated cooling capacity (35 Β°C)
18.10 kW
Cooling power input
5.40 kW
Rated heating capacity (7 Β°C)
18.70 kW
Heating power input
5.30 kW
EER, full load (tested)
3.37
COP, full load (tested)
3.60
Rated AEER
3.31
Rated ACOP
3.48
Standby power (PIA)
20.0 W
Compressor
Fixed speed
Refrigerant
R410A
Power supply
Three phase
Indoor sound power
–
Outdoor sound power
–
Demand response (AS/NZS 4755)
No
Country of manufacture
Malaysia

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

AIRSTAGE RAQ zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––3,4962,902
Coldresidential1.51.01,5348,506
Mixedcommercial––4,3041,590
Mixedresidential1.51.52,3093,402
Hotcommercial––9,266365
Hotresidential1.51.56,747572
Part-load test points (4 values)
h__h2_full_cap_power_rated
4960 W
h__h3_have_full_cap_results
No
h__h2_full_cap_heat_cap_rated
16290 W
c__low_temp_have_full_cap_results
No

Other model numbers on registration AAC6598

Registered together and sharing the same test results. Usually variants of the same unit.

New Zealand E3 registration details

Registration number
AAC6598
GEMS registration id
145915
Status
approved, available (self-reported)
Registration expires
6 April 2027
Registered for sale in
Australia, New Zealand
Family
RAQ/K/EC/WP/*17
Regulatory standard
[SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
Test standard
AS/NZS 3823.1.2:2012
MEPS
2019
Product class
Class 6

Source: E3 programme registration data (EECA, New Zealand) (trans-Tasman E3 registration data published by DCCEEW on data.gov.au, CC BY 3.0 AU). Dataset published 25 September 2026; last checked 26 September 2026. Manufacturer: fujitsugeneral.com.au. How the derived figures are calculated.