c/kWh
Energy rating (cooling)
1
Heating: 1.5
Annual electricity use
6,131 kWh
1,033 cooling + 5,098 heating
Estimated running cost
$2,023 / year
$169 / month Β· $20,232 over 10 years
Capacity
11.4 kW cooling
11.7 kW heating

About the same electricity as the median of 146 comparable 12.5 kW reverse cycle ducted split system registrations (6,125 kWh a year) in the cold zone. Uses less than 49% of them.

Across all 3,611 air conditioner registrations sold in Australia, it uses less than 30% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ— 33c/kWh in NZD; change the price above to your tariff.

APAC S012OVR3SA running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 6,131$2,023$20,232
Mixed zone 3,584$1,183$11,827
Hot zone 4,573$1,509$15,091

At 33c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Heat pumps that use less electricity

Same configuration and type, cooling capacity within 12% of 11.4 kW, at least 3% lower annual kWh in the cold zone.

ModelStarsEst. cost / yrCompare
Brivis AONSR13B1/AINHU11B111.3 kW heating10.3 kW cooling3,713 kWh/yr5$1,225
Midea DUCMI105IB/UCMI105OB11 kW heating10.5 kW cooling4,207 kWh/yr4.5$1,388
Midea UCMI90OB/DUCMI90IB11 kW heating10.5 kW cooling4,207 kWh/yr4.5$1,388
Mdv C-UV-105N8-QC3W / CDV-105HN8-QC3W11 kW heating10.5 kW cooling4,244 kWh/yr4.5$1,401
Mdv C-UV-105N8-QC3W / CDV-105A6N8-QC3W11 kW heating10.5 kW cooling4,253 kWh/yr4.5$1,403

Heat pumps similar to the APAC S012OVR3SA

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
Fujitsu AOTG45LBTB/ARTG45LHTDP14 kW heating11.5 kW cooling6,162 kWh/yr3$2,033
Fujitsu AOTG45LBTC/ARTG45LHTA14 kW heating11.5 kW cooling6,406 kWh/yr2.5$2,114
Braemar KCDB145D1B/KGDB145A1S12.1 kW heating11.6 kW cooling5,325 kWh/yr2.5$1,757
Mitsubishi Electric PUZ-M125VKA2-A/PEA-M125HAA214 kW heating12 kW cooling6,455 kWh/yr2$2,130
Samsung Electronics AC120TXAPKG/SA / AC120TNHDKG/SA14 kW heating12 kW cooling5,952 kWh/yr3$1,964
Mitsubishi Electric PUZ-M125VKA2-A/PEA-M125HAA14 kW heating12 kW cooling6,455 kWh/yr2$2,130
Samsung Electronics AC120TXAPNG/SA / AC120TNHDKG/SA14 kW heating12 kW cooling5,952 kWh/yr3$1,964
Brivis AONSR13B1/AINHU13B113.8 kW heating12 kW cooling4,365 kWh/yr4.5$1,440

Compare S012OVR3SA/S012ILR1SA- with another model

APAC S012OVR3SA specifications

Type
Reverse cycle
Configuration
Split system
Air distribution
Ducted
Indoor unit
–
Rated cooling capacity (35 Β°C)
11.38 kW
Cooling power input
3.30 kW
Rated heating capacity (7 Β°C)
11.74 kW
Heating power input
2.97 kW
EER, full load (tested)
3.26
COP, full load (tested)
3.77
Rated AEER
3.29
Rated ACOP
3.76
Standby power (PIA)
46.2 W
Compressor
Fixed speed
Refrigerant
R410A
Power supply
Three phase
Indoor sound power
–
Outdoor sound power
–
Demand response (AS/NZS 4755)
No
Country of manufacture
Australia, Malaysia

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

APAC S012OVR3SA zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––2,1521,752
Coldresidential1.01.51,0335,098
Mixedcommercial––2,648977
Mixedresidential1.01.51,5232,061
Hotcommercial––5,606276
Hotresidential1.51.54,163410
Part-load test points (6 values)
h__h2_full_cap_power_rated
2740 W
h__h3_have_full_cap_results
No
h__h2_full_cap_heat_cap_rated
9480 W
c__low_temp_full_cap_power_rated
2950 W
c__low_temp_have_full_cap_results
Yes
c__low_temp_full_cap_cooling_cap_rated
12270 W

Other model numbers on registration AAC7460

Registered together and sharing the same test results. Usually variants of the same unit.

New Zealand E3 registration details

Registration number
AAC7460
GEMS registration id
153252
Status
approved, available (self-reported)
Registration expires
2 May 2028
Registered for sale in
Australia, Fiji, New Zealand
Family
S012OVR3SA/S012ILR1SA-
Regulatory standard
[SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
Test standard
AS/NZS 3823.1.2:2012
MEPS
2019
Product class
Class 11

Source: E3 programme registration data (EECA, New Zealand) (trans-Tasman E3 registration data published by DCCEEW on data.gov.au, CC BY 3.0 AU). Dataset published 25 September 2026; last checked 26 September 2026. Manufacturer: rinnai.com.au. How the derived figures are calculated.